display RENAULT KANGOO 1997 KC / 1.G Foult Finding - Injection Manual PDF

Page 335 of 363

v0406.0
IMMOBILISER
Fault finding - Checking conformity
82
If a fault bargraph illuminates, refer to the corresponding fault chart.NOTES
Order of
operationsFunction to be
checkedAction Bargraph Display and notes
16Information on
programming or
resynchronisation of
PLIP in progressIlluminated if programming or
resynchronisation in progress
(PLIP).
17Programming not
carried out for PLIP
informationIlluminated if programming
not carried out (PLIP).
18 Programming of 1st
key informationNot used.
19 Programming not
carried out for key
informationIlluminated if programming
not carried out (key).
20Programming not
confirmed for key
informationIlluminated if programming
not confirmed (key).
G60* : changes to 1 when
setting is completed.
21Sending of
information is blocked
Enter security code
17
18
19
17
19
20
82-38

Page 337 of 363

v0406.0
IMMOBILISER
Fault finding - Aid
82
ADDITIONAL CHECKS
COMMAND MODES G--*
40Entering the security code (Bargraph 10 left should be illuminated and the ignition turned on).
This command mode can be used to enter the security code but does not permit decoding of the
injection computer or of the coded solenoid valve.
Enter the number of the vehicle’s security code on the XR25 and validate with "*".
If the code number is correct, "bon" is displayed on the XR25 and bargraph 10 left extinguishes.
If the code number is incorrect, "Fin" is displayed on the XR25 and bargraph 10 left remains
illuminated.
IMPORTANT: 3 attempts may be made to enter the code. If, after the 3rd attempt, the code
remains invalid,you must wait for approximately 15 minutes before trying again (the ignition must
be switched on and off again between each attempt.)
47Configuration of courtesy light timer :
-G 47 * 0 * = cancels courtesy light timer.
-G 47 * 1 * = activates courtesy light timer.
70Reading the Part Number (Part number of the decoder unit).
LIST OF THE VARIOUS #
43Type of button for electric door locks.
26Source of the last command for the opening elements:
1→Infrared remote control
2→Central door locking button
27Operation of the last command for the opening elements :
1→Unlock
2→Lock
65Test E2 Prom.
95Manufacturer (1 = Valéo, 2 = Sagem).
82-40

Page 341 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding -Wiring
Fault finding - XRBAG fiche
Pretensioner only
88
DI8811.1
Correct insulation value: display≥ 100 h or 9999 flashing
PRETENSIONERS
Measuring point Correct Value
C0, C1 and C3 1.6 to 4.6 Ω
AIndependent unit
BDriver seat
CPassenger seat
DPretensioners
+ 12 V
Earth
H
88-2

Page 342 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding -Wiring
Fault finding - XRBAG Fiche
Pretensioner and driver airbag
88
DI8812.3
Correct insulation value : display≥ 100 h or 9999 flashing
PRETENSIONERS
Measuring point Correct value
C0, C1 and C3 1.6 to 4.6 Ω
AIRBAG
Measuring point Correct value
C0, C2 and C4 2 to 9.4 Ω
CT Rotary switch
A1 +12 Volts
A3 Earth
A2 Warning light
B1
B2Diagnostic socket A Central unit
B Driver seat
C Passenger seat
D Pretensioners
E Driver’s airbag ignition module
88-3

Page 343 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding -Wiring
Fault finding - XRBAG Fiche
Pretensioner , driver’s airbag and passenger’s airbag
88
DI8813.2
PRETENSIONERS
Measuring point Correct value
C0, C1 and C3 1.6 to 4.6 Ω
AIRBAG
Measuring point Correct value
Driver C0, C2 and C4 2 to 9.4 Ω
Passenger C0 and C4 1.6 to 4.6 Ω
CT Rotary switch
A1 +12 Volts
A3 Earth
A2 Warning light
B1
B2Diagnostic socket A Central unit
B Driver’s seat
C Passenger’s seat
D Pretensioners
E Driver’s airbag ignition module
G Passenger’s airbag ignition module
Correct insulation value : display≥ 100 h or 9999 flashing
88-4

Page 345 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding - XR25 fiche
MEANING OF BARGRAPHS
FAULT BARGRAPHS
(always on coloured background)
If illuminated, indicates a fault on the product tested. The associated text defines
the fault.
This bargraph could be :
- Illuminated : fault present.
- Flashing : fault memorised.
- Extinguished : fault absent or not found.
STATUS BARGRAPHS (always on a white background)
Bargraph always located on the top right hand side
If illuminated , indicates establishment of dialogue with the product computer.
If it remains extinguished :
- The code does not exist.
- There is a tool, computer or XR25 / computer connection fault.
The following bargraph representations indicate their initial status :
Initial status: (ignition on, engine stopped, no operator action)
Indefinite
illuminated when the operation or the condition specified on the
fiche is met.
Extinguished
Illuminated extinguished when the operation or the condition specified on the
fiche is no longer met.
ADDITIONAL SPECIFICATIONS
Certain bargraphs have a *. The command *.., when the bargraph is illuminated,
allows additional information on the type of fault or status to be displayed.
or
88
88-6

Page 348 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding - Interpretation of XR25 bargraphs
Bargraph 2 left hand side illuminated Fiche n° 49
Voltage supply
XR25 aid:*02 : 1.dEF : Voltage too low
2.dEF : Voltage too high
3.dEF : Too many micro-breaks
dEF : Cumulative between faults 1.dEF/2.dEF/3.dEF
2
Use the 30 track adaptor of the XRBAG to operate on the computer connector .
Erase the computer memory using the command G0**. AFTER REPAIR NOTES
Carry out the operations necessary to obtain the correct computer power supply :
10.5 volts ± 0.1 < correct voltage< 16 volts ± 0.1.
- Check the battery charge.
- Check the charge circuit.
- Check the tightness and condition of the battery terminals.
- Check the computer earth .
NoneNOTES I.dEF - 2.dEF
For a micro-break fault, check the computer power supply lines :
- Condition of the computer connections.
- Condition of computer earth (track 9 of the 30 track connector towards front right pillar earth).
- Condition / position of the fuse.
- Condition and tightening of battery terminals.
NoneNOTES 3.dEF
The dEF display on the kit indicates the minimum memorisation of 2 of the 3 faults declared by the
display
1.dEF, 2.dEF and 3.dEF (bargraph flashing ).
Operation:
- Check the battery charge.
- Check the charge circuit.
- Check the tightness and condition of the battery terminals.
- Condition of the computer connections.
- Check the computer earth .
- Condition / position of the fuse.
NoneNOTES dEF
88
88-9

Page 361 of 363

1EC761.0
AIRBAG - SEAT BELT PRETENSIONERS
Fault finding - Checking conformity
Only carry out this conformity check after a complete XR25 check.NOTES
Order of
operationsOperation to be
checked Action Bargraph Display and remarks
1 XR25 dialogueD49
(selector on
S8)
I.Ab
2 Computer Conformity
#022 2
3 Computer
Configuration Ensure that the computer
configuration shown by these 3
bargraphs corresponds to the
vehicle equipment.
4Warning light
operation - check
computer
initialisation Switch on the
ignition 3 second illumination of the
warning light when turning on
the ignition (consult fault
finding if it remains
illuminated or if it does not
illuminate).
17 / 18 / 19
88
88-22

Page:   < prev 1-10 ... 31-40 41-50 51-60 61-70 71-80