RENAULT KANGOO 1998 KC / 1.G Heating And Ventilation Owner's Guide

Page 31 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 1
CONT
A
no
Check the condition of the kinematic
(sprockets, levers...) on the air distribution
unit and the control panel.
Is it correct?
Remove the air distribution unit and check
the distribution flaps.
Repair or change the unit.
Repair if possible,
otherwise change the distribution unit or the
control panel.
62-20

Page 32 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 2AIR FLOW PROBLEM
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
NOTES
no
yes
yes
yesSee CHART 1.
no
noEnd of fault finding.
Does the passenger compartment fan
operate?noSee CHART 9.
Repair or clean or change
the particle filter.Check the air intake circuit, scuttle panel
grille, particle filter, rain shield.
Are they correct?
Check that the air extraction circuit
is not blocked.
Repair if necessary.
Does the fault persist?
Is it a passenger compartment
air distribution problem?
Remove the heater radiator.
It must be blocked, clean or change it
(only valid for vehicles which have been
driven without the particle filter).
62-21

Page 33 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
no
CHART 3HEATER PERFORMANCE POOR
NOTES
yes
Advise the customer how to use the heating
system correctly
(eg. : Do not place the passenger
compartment fan on full when starting from
cold, turn it up gradually instead).
Carry out a road test to observe the customer
complaints.
Is the test satisfactory?
yes
A
yes
yes
noSee CHART 1.
no
noEnd of fault finding.
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Visually check that
the action of the control moves
the mixing flap.
Does the flap move?
Visually check
whether the flap travel is complete.
Is it complete?
Check the cooling circuit
(correct filling and bleeding),
the condition of the circuit (pipes,
connections, conformity
of the circuit...).
Repair if necessary.
Does the fault persist?
Readjust the control cable
(cable which controls the sprockets to the
right of the air distribution unit).
62-22

Page 34 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the components which were removed are connected correctly.
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 3
CONT
A
noChange the thermostat.
yes
yes
noEnd of fault finding.
noEnd of fault finding.
With the engine cold, remove the engine
coolant thermostat and check that it is not
jammed in the open position.
Is it correct?
Check that there is no unwanted intake of
cold air into the passenger compartment
(seals, grommets, cables ...).
Repair if necessary
Does the fault persist?
Check the air inlets (particle filter)
and outlets.
Partially blocked air inlets or outlets
reduce the flow of heated air
into the
passenger compartment.
Repair if necessary.
Does the fault persist?
The heater radiator must be blocked. Remove
the radiator and clean or change it
(only valid for vehicles which have been
driven without the particle filter).
62-23

Page 35 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
no
CHART 4NO HEAT
NOTES
Is it an air flow problem?yesSee CHART 2.
yes
yes
noSee CHART 1.
noEnd of fault finding.
noEnd of fault finding.
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Check the level of coolant in the cooling
circuit.
NOTE: if the coolant level is too low, the cir-
cuit may become unprimed when driving at
low load and at idle.
Repair if necessary.
Does the fault persist?
Visually check that moving the control
moves the mixing flap.
Does it move?
yes
Check the coolant circuit.
NOTE: fitting an oil, water or air cooler which
has not been approved by the research centre
and which is incorrectly connected may re-
duce or even stop the flow of coolant in the
heater radiator.
Repair the coolant circuit if necessary.
Does the fault persist?
Remove the heater radiator.
Clean or change it if necessary.
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-24

Page 36 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
Check that the system operates correctly.AFTER
REPAIR
yes
CHART 5TOO HOT
NOTES
noSee CHART 1.
noReadjust the cable
(to the right of the air distribution unit).
yes
yesSee CHART 11.
no
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Visually check that moving the control
moves the mixing flap.
Does it move?
Check that the flap travel
is complete.
Is the travel complete?
Check the operation
of the recirculation flap.
Is it jammed in the recirculation position?
Check the operation
of the engine coolant thermostat.
Change the thermostat if necessary.
62-25

Page 37 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
yes
CHART 6HEATING INADEQUATE IN THE REAR
NOTES
noFree the air outlets.
None.
Check that the air inlets at the rear of the
centre console are not blocked.
(floor carpet...).
Are they correct?
Remove the centre console and check
that the connection and sealing between the
air distribution unit and the heating duct to
the rear seats is correct.
Repair if necessary.
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-26

Page 38 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
CHART 7DEICING/DEMISTING PERFORMANCE POOR
NOTES
See CHART 1.
yes
yes
yes
See CHART 2.
no
yes
See CHART 3.
no
yes
no
Check that the recirculation flap is not
jammed in the recirculated air position
(see CHART 11).
Repair if necessary.
Is it a heater performance problem?
Is it an air flow problem?
Is it an air distribution problem?
Check that the windows are clean on the inside.
End of fault finding.no
End of fault finding.no
Check that the air extractors
are not blocked.
Repair if necessary.
Does the fault persist?
Ensure that there are no water leaks into the
passenger compartment which would
significantly increase the humidity level and
reduce the effectiveness of the demisting.
Locate the leak and repair it.
Does the fault persist?
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-27

Page 39 of 73

c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
no
CHART 8VENTILATION PERFORMANCE POOR
NOTES
Is it an air flow problem?yesSee CHART 2.
yesSee CHART 1.
no
yesEnd of fault finding.
Is it an air distribution problem?
Check that the mixing flap
travel is complete.
Is is correct?
None.
no
Readjust the cable.
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-28

Page 40 of 73

Check the condition of the wiring between:
B2 A2
control B3 A1 resistance
panel B4 C4 unit
B5 C1
Is the wiring in good condition?
yes
c11010.0
AIR CONDITIONING
Fault finding charts
62
KANGOO
ALL TYPES
AFTER
REPAIR
yes
CHART 9PASSENGER COMPARTMENT FAN DOES NOT OPERATE
NOTES
Check fuses +battery, +fuse board, +side
lights. Are the fuses in good condition?noChange the faulty fuse(s).
noEnd of fault finding.
yes
noChange the control panel.
yes
noRepair the faulty
electrical wiring.
A
Before carrying out any work, check that the customer uses the air conditioning
correctly.
Non regulated air conditioning.
Check the connections between the fuses
and the instrument panel connector.
Repair if necessary.
Does the fault persist?
With the ignition on and the air conditioning
selected, position the ventilation at the
various speeds and check that 12 V
is present on the tracks of the
control panel connector:
- B5 in position 1,
- B4 in position 2,
- B2 in position 3,
- B3 in position 4.
Is 12 V present?
Check that the components which were removed are connected correctly.
Check that the system operates correctly.
62-29