diagram RENAULT SCENIC 2006 J84 / 2.G Multimedia Nav 4R Workshop Manual

Page 1 of 86

Electrical equipment
77 11 322 302
"The repair procedures given by the manufacturer in this document are based on the
technical specifications current when it was prepared.
The procedures may be modified as a result of changes introduced by the
manufacturer in the production of the various component units and accessories from
which his vehicles are constructed."
MARCH 2006
All rights reserved by Renault s.a.s.
EDITION ANGLAISE
Copying or translating, in part or in full, of this document or use of the service part
reference numbering system is forbidden without the prior written authority of
Renault s.a.s.
© Renault s.a.s. 2006
MULTIMEDIA
NAV 4R
Program no.: 0000
Vdiag No.: 24
Fault finding - Introduction 86C - 1
Fault finding - List and location of components 86C - 8
Fault finding - Operating diagram 86C - 11
Fault finding - Functions 86C - 12
Fault finding - Role of components 86C - 13
Fault finding - Configuration and programming 86C - 14
Fault finding - Replacement of components 86C - 15
Fault finding - Fault summary table 86C - 17
Fault finding - Interpretation of faults 86C - 18
Fault finding - Conformity check 86C - 29
Fault finding - Status summary table 86C - 34
Fault finding - Interpretation of statuses 86C - 35
Fault finding - Parameter summary table 86C - 46
Fault finding - Interpretation of parameters 86C - 47
Fault finding - Command summary table 86C - 56
Fault finding - Dealing with commands 86C - 57
Fault finding - Customer complaints 86C - 61
Diagnostic - Fault finding chart 86C - 63
86C

Page 2 of 86

MULTIMEDIA
Fault finding - Introduction
86C
86C-1
186C
NAV 4R
Program no.: 0000
Vdiag No.: 24MULTIMEDIA
Fault finding - Introduction
1. SCOPE OF THIS DOCUMENT
This document presents the fault finding procedure applicable to all computers with the following specifications:
2. PREREQUISITES FOR FAULT FINDING
Documentation type
Fault finding procedures (this manual):
–Assisted fault finding (integrated into the diagnostic tool), Dialogys.
Wiring Diagrams:
–Visu-Schéma (CD-ROM),
Type of diagnostic tools
–CLIP + multiplex line probe
Special tooling required
3. RECAP
For commercial vehicles, fault finding can only be run on the 4R Radio Navigation Computer by clicking on the Fault
finding - NAV4R Central Communication Unit - Commercial vehicles icon in the Help directory on the CLIP computer
desktop.
To run fault finding on the vehicle's computers,
Proceed as follows, depending on the type of equipment:Vehicle(s): Mégane II ph2, Master ph2 and ph3,
Master propulsion ph2 and ph3, Laguna II ph2,
Trafic II ph1 and ph2, Scénic II ph2
Function concerned: 4R Radio NavigationName of computer: 4R Radio Navigation
Computer
Program No.:0000
Vdiag No.: 24
Special tooling required
Multimeter
Elé. 1681Universal bornier
For vehicles with radio frequency remote control/key,
switch on the ignition with the key.
For vehicles with a Renault card,
to save energy, the vehicle's UCH cuts off the + after ignition feed after a certain period of time. It is essential to
force the + after ignition feed by applying the following procedure:
–with the vehicle card in the card reader,
–press and hold (5 seconds +) the Start button with starting conditions not fulfilled until the diode on the instrument
panel starts to flash rapidly,
–connect the diagnostic tool and perform the required operations.
NAV4R_V24_PRELI

Page 8 of 86

To check the GPS reception status, follow the procedure below:
Position the vehicle in an open area
Wait for 15 minutes with the ignition on
In the navigation system, go to Fault finding: Navigation →→ → →
Configuration →→ → →
System information →→ → →
Fault finding→→ → →
GPS status
Vehicle speed signal fault finding, change of value when driving? YES NO
To run this fault finding procedure on the navigation system, from the following fault finding menu: Navigation →→ → →
Configuration →→ → →
System
information →→ → →
Fault finding →→ → →
I/O
Vehicle restart
after a cut-off of > 1 min: OUT NO
after a cut-off of <1 min: OUT NO
By action on: .................................................................................................................................................................................................
.................................................................................................................................................................................................
The fault disappears by itself (state time): .............................................................................................................. .............................................
Other (give as much detail as possible): ..............................................................................................................................................................
.............................................................................................. ...............................................................
FAULT FINDING LOG
System: Carminat Advanced NavigationPage 2 of 2
●Documentation used in fault finding
Fault finding procedure used
Type of diagnostic manual:
Workshop Repair Manual Technical Note Assisted fault finding
Fault finding manual number
Wiring diagram used
Wiring Diagram Technical Note Number:
Other documentation
Title and/or part number:

Workshop fault finding
GPS reception status:
COM.ERROR Search Sat ≥ 3 sat
Status red LED computer front panel:
Permanently off Permanently flashing Permanently lit
Carminat computer (CD-ROM reader):
Impossible to insert CD Impossible to eject CD Refuses to read CD
Cartographic map CD scratched or dirty:
YES NO

Conditions under which fault disappears
●Parts returned
Parts: Navigation computer CCU Keypad Screen
Note:
Complete and submit a fault finding log for each component removed and returned.
FD98
Fault finding log
page to print or photocopy - page to print or photocopy - page to print or photocopy

Page 12 of 86

MULTIMEDIA
Fault finding - Operating diagram
86C
86C-11
NAV 4R
Program no.: 0000
Vdiag No.: 24
Fault finding - Operating diagram
Layout of the main components of the 4R Radio Navigation system
Video screen fold-out
unit (Only on Mégane II
phase 2)GPS aerial
Diagnostic socket
CD multi-changer (optional)
Instrument panel
(Dot matrix display)
(Only on Mégane II phase 2)
Display 4R Radio
Navigation computerDepending on the vehicle
–Thermometer
–Speed signal
–Seat belt warning light
–+ side light feed
–Radio aerial
Steering wheel radio
satellite control
Speakers
- Multimedia multiplex network
- Wire connections

Page 19 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-18
NAV 4R
Program no.: 0000
Vdiag No.: 24
Fault finding - Interpretation of faults
DF001
PRESENT
OR
STOREDCOMPUTER
1.DEF : Internal electronic fault
NOTESConditions for applying fault finding procedures to stored faults:
Apply the interpretation of the fault shown below.
Use the Wiring Diagram Technical Note for the vehicle concerned.
DF001 PRESENT
Contact the Techline.
DF001 STORED
Check the conformity of + 12 V on connection BCP3 (commercial vehicle and Laguna: BCP4) of the 8-track
black connector of component 261 (Trafic: 662).
Check that the earth on connection MT (for Laguna and Trafic), MAO (for Mégane and Scénic), NL (for
Master) of the 8-track black connector of component 261 (Trafic: 662) is in perfect condition.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Clear the fault, switch off the ignition and disconnect the computer supply fuse:
Laguna: 20A fuse located on component 710.
Mégane and Scénic: 20A fuse located on component 260.
Master: 10A fuse located on component 1016.
Trafic: 15A fuse located on component 1016.
–Refit the fuse and switch the ignition back on.
–Switch on the 4R radio navigation system.
If the fault reappears as stored, contact Techline.
AFTER REPAIRIf the 4R radio navigation system has been replaced (upon request and with Techline
approval), reconfigure the 4R radio navigation system computer (see Configuration
and programming).
Deal with any other faults.
NAV4R_V24_DF001

Page 21 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-20
NAV 4R
Program no.: 0000
Vdiag No.: 24
DF024
PRESENT
OR
STOREDNO INSTRUMENT PANEL MULTIPLEX SIGNAL
1.DEF : No communication with the instrument panel
NOTESOrder of priority in the event of more than one fault:
If faults DF024 No instrument panel multiplex signal and DF026 No fold-out unit
multiplex signal are present, run command VP005 Computer configuration to
reconfigure the system (see Configuration and programming).
Conditions for applying fault finding procedures to stored faults:
Apply this fault finding procedure if the fault reappears as present or stored after it has
been cleared and the ignition has been switched off and on again.
Special note:
Apply this fault procedure only for vehicles equipped with an instrument panel dot
matrix display (Top of the range Mégane II phase 2).
Use the Wiring Diagrams Technical Note for the Mégane II.
Look for any damage to the wiring harness, check the condition and connection of the connectors on
components 261 and 247.
Manipulate the wiring harness in order to produce a change in the fault status (present → stored).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Using the universal bornier, check the insulation, continuity and the absence of interference resistance on
the following connections:
●connection code 107W,
●connection code 107X,
between components 261 and 247.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, run fault finding on the instrument panel (see 83A, Instrument panel) and the multiplex
network (see 88B, Multiplexing).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the 4R radio navigation computer memory using command RZ001
Fault memory.
NAV4R_V24_DF024

Page 22 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-21
NAV 4R
Program no.: 0000
Vdiag No.: 24
DF026
PRESENT
OR
STOREDNO FOLD-OUT UNIT MULTIPLEX SIGNAL
1.DEF : No communication with the display fold-out unit
NOTESOrder of priority in the event of more than one fault:
If faults DF024 No instrument panel multiplex signal and DF026 No fold-out unit
multiplex signal are present, run command VP005 Computer configuration to
reconfigure the system (see Configuration and programming).
Conditions for applying fault finding procedures to stored faults:
Apply this fault finding procedure if the fault reappears as present or stored after it has
been cleared and the ignition has been switched off and on again.
Special note:
Apply this fault procedure only for vehicles equipped with a fold-out unit (Top of the
range Mégane II phase 2).
Use the Wiring Diagrams Technical Note for the Mégane II.
Look for any damage to the wiring harness, check the condition and connection of the connectors on
components 261 and 1303.
Manipulate the wiring harness in order to produce a change in the fault status (present → stored).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Using the universal bornier, check the insulation, continuity and the absence of interference resistance on
the following connections:
●connection code 34GA,
●connection code 34DZ,
●connection code 34GG,
●connection code BCP3,
between components 261 and 1303.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + 12 V on connection BCP3 of the connector of component 1303.
Also check for earth on connection MAN of the connector of component 1303.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, run fault finding on the multiplex network (see 88B, Multiplexing).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the 4R radio navigation computer memory using command RZ001
Fault memory.
NAV4R_V24_DF026

Page 23 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-22
NAV 4R
Program no.: 0000
Vdiag No.: 24
DF027
PRESENT
OR
STOREDNO AUDIO CD CHANGER SIGNALS
1.DEF : No communication with the CD changer
NOTESOrder of priority in the event of more than one fault:
Deal with fault DF001 Computer first, if present or stored.
Conditions for applying fault finding procedures to stored faults:
Apply this fault finding procedure if the fault reappears as present or stored after it has
been cleared and the ignition has been switched off and on again.
Special note:
If the vehicle does not have a CD changer, check the 4R radio navigation computer
configuration (see Configuration and programming).
Apply the following fault finding procedure to vehicles equipped with a CD changer.
Use the Wiring Diagram Technical Note for the vehicle concerned.
Look for any damage to the wiring harness, check the condition and connection of the connectors on
components 261 and 1272.
Manipulate the wiring harness in order to produce a change in the fault status (present → stored).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Using the universal bornier, check the insulation, continuity and the absence of interference resistance on
the following connections:
●connection code 34AZ,
●connection code 34BA,
●connection code 34BL,
●connection code 34BC,
●connection code 34BD,
●connection code 34BG,
●connection code 34BH,
●connection code 34BK (only for Scénic),
between components 261 and 1272.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the 4R radio navigation computer memory using command RZ001
Fault memory.
NAV4R_V24_DF027

Page 24 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-23
NAV 4R
Program no.: 0000
Vdiag No.: 24
DF030
PRESENT
OR
STOREDGPS AERIAL CIRCUIT
CO : Open circuit
NOTESConditions for applying fault finding procedures to stored faults:
Apply this fault finding procedure if the fault reappears as present or stored after it has
been cleared and the ignition has been switched off and on again.
Use the Wiring Diagram Technical Note for the vehicle concerned.
Check the condition and connection of the GPS coaxial connector on components 261 (Trafic: 662) and 886
(and 1551 for Laguna and Mégane cabriolet) (bent pins, bad contacts, etc.).
Carefully manipulate the wiring harness in order to produce a change in fault status (present → stored).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Using the universal bornier, check the insulation, continuity and the absence of interference resistance on
the following connections:
Mégane cabriolet:
●connection code TB13,
●connection code 34AN,
between components 261 and 886;
●connection code 46CB,
●connection code TB15,
between components 886 and 1551.
Mégane hatch and Scénic:
●connection code TB13,
●connection code 34AN,
●connection code 46CB,
●connection code TB15,
between components 261 and 886.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the faults from the 4R radio navigation computer memory using command RZ001
Fault memory.
Check the number of satellites received from outside, with the system switched on for
10 minutes, followed by a new check with the diagnostic tool.
NAV4R_V24_DF030

Page 27 of 86

MULTIMEDIA
Fault finding - Interpretation of faults
86C
86C-26
NAV 4R
Program no.: 0000
Vdiag No.: 24
DF032
PRESENT
OR
STOREDDISPLAY SUPPLY
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying fault finding procedures to stored faults:
Apply this fault finding procedure if the fault reappears as present or stored after it has
been cleared and the ignition has been switched off and on again.
Special note:
Run command AC021 Display test. Three colours are displayed on the screen: Red,
green and blue, and a black mosaic on a white background. If this is not displayed,
apply the fault finding procedure detailed below.
Use the Wiring Diagram Technical Note for the vehicle concerned.
Check the condition and connection of the video connector on components 261 (Trafic: 662) and 1127 (bent
pins, bad contacts, etc.).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Using the universal bornier, check the insulation, continuity and the absence of interference resistance on
the following connections:
●connection code 46M,
●connection code 46N,
●connection code 46BG,
●connection code 46BH,
●connection code 46BK,
between components 261 (Trafic: 662) and 1127.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + 12 V on connections 46M and 46N of the connector of component 1127.
Also check for earth on connections 46BG, 46BH and 46BK of the connector of component 1127.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRCheck that the screen is operating correctly using command AC021 Display test.
Deal with any faults displayed by the diagnostic tool.
Clear the faults from the 4R radio navigation computer memory using command RZ001
Fault memory.
NAV4R_V24_DF032