AUTOMATIC TRANSMISSION
Fault finding – Introduction23A
23A - 3V4 MR-372-J84-23A050$066.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
To cut off + after ignition, proceed as follows:
–Disconnect the diagnostic tool.
–Press the Start button twice briefly (less than 3 seconds).
–Ensure that the + after ignition feed has been cut off by checking that the computer indicator lights on the
instrument panel have gone out.
Faults
Faults are declared either present or stored (depending on whether they appeared in a certain context and
disappeared since, or whether they remain present but have not been diagnosed within the current context).
The present or stored status of faults should be taken into consideration when the diagnostic tool is switched on
after the + after ignition feed (without any system components being active).
For a present fault, apply the procedure described in the Interpretation of faults section.
For a stored fault, note the faults displayed and apply the instructions in the Notes section.
If the fault is confirmed when the instructions in the Notes section are applied, the fault is present. Deal with the fault
If the fault is not confirmed, check:
–the electrical lines which correspond to the fault,
–the connectors for these lines (for oxidation, bent pins, etc.),
–the resistance of the component detected as faulty,
–the condition of the wires (melted or split insulation, wear).
Conformity check
The aim of the conformity check is to check data that does not produce a fault on the diagnostic tool because the
data is inconsistent. Therefore, this stage is used to:
–carry out fault finding on faults that do not have a fault display, and which may correspond to a customer
complaint.
–check that the system is operating correctly and that there is no risk of a fault recurring after repairs.
This section gives the fault finding procedures for statuses and parameters and the conditions for checking them.
If a status is not behaving normally or a parameter is outside the permitted tolerance values, consult the
corresponding fault finding page.
Customer complaints - Fault finding chart
If the test with the diagnostic tool is OK but the customer complaint is still present, the fault should be processed by
customer complaint. Note:
The left and right-hand xenon bulb computers are supplied when the dipped headlights are lit.
Therefore fault finding can only be carried out on them after the ignition has been switched on in fault finding mode
(forced + after ignition feed) and the dipped headlights have been switched on.
A synopsis of the general procedure to follow is provided on the following page in the form of a flow chart.

Page 119 of 128

AUTOMATIC TRANSMISSION
Fault finding – Fault Finding Chart23A
23A-119V4 MR-372-J84-23A050$924.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
ALP3
CONTINUED 2
Refer to the procedure and the safety instructions for carrying out a setting point check on the torque converter.
Theoretical engine speed at setting point: 2300 ± 150 rpm
Is the value of the setting point wrong or is there an internal noise in the converter?
Carry out a road test, observing the engine
speed on the instrument panel and the
information displayed on the diagnostic tool
(PR006 Engine speed)Replace the torque converter, the lock-up solenoid
valve and the oil. If the oil is burnt, also replace the
hydraulic distributor and all the solenoid valves
(see MR 364 Mechanical, 23A, Automatic
transmission, Hydraulic distributor
(for Mégane II) and MR 370 Mechanical, 23A,
Automatic transmission, Hydraulic distributor
(for Scénic II)).
When replacing the torque converter, ensure that the
reaction shaft is securely attached to the hub of the
oil pump (flanged shaft).
Note:
A setting point which is too low may be due to a lack
of engine power. Does the engine speed change each time
there is a gear change?

The checks carried out have not provided any
evidence of a fault and the automatic
transmission appears to be working correctly.
If the vehicle does show the customer complaint
selected, continue with the entire fault finding
procedure. Replace the hydraulic distributor and all the solenoid
valves. (see MR 364 Mechanical, 23A, Automatic
transmission, Hydraulic distributor
(for Mégane II) and MR 370 Mechanical, 23A,
Automatic transmission, Hydraulic distributor
(for Scénic II)).
B
NOYES
YESNO
AFTER REPAIRCarry out a road test followed by a complete check with the diagnostic tool.