ABS RENAULT SCENIC 2008 J84 / 2.G Automatic Transmission Siemens TA2000 Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2008, Model line: SCENIC, Model: RENAULT SCENIC 2008 J84 / 2.GPages: 128, PDF Size: 0.43 MB
Page 5 of 128
AUTOMATIC TRANSMISSION
Fault finding – Introduction23A
23A - 5V4 MR-372-J84-23A050$066.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of the voltage, resistance and insulation are generally correct, especially if the fault is not
present when analysing (stored fault).
Visual inspection
Look for damage under the bonnet and in the passenger compartment.
Carefully check the fuses, insulators and wiring harness routing.
Look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored or
present.
Check that the connectors are correctly locked.
Apply light pressure to the connectors.
Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
Disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no crimping on
the insulating section).
Check that the clips and tabs are correctly locked in the sockets.
Make sure that no clips or tabs have been dislodged during connection.
Check the clip contact pressure using an appropriate model of tab.
Check the continuity/insulation
Check the continuity of entire lines, then section by section.
Look for a short circuit to earth, to + 12 V or to another wire.
If a fault is detected, repair or replace the wiring harness.
Page 16 of 128
AUTOMATIC TRANSMISSION
Fault finding – Fault summary table23A
23A - 16V4 MR-372-J84-23A050$264.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
* RR: rear
* FR: frontTool fault Diagnostic tool title
DF116 Engine multiplex speed signal
DF117 Left RR* wheel multiplex speed signal
DF118 Right RR* wheel multiplex speed signal
DF119 Brake pedal position
DF122 Passenger compartment computer connection
DF123 ABS computer connection
DF126 Turbine speed signal
DF131 Slip
DF144 Coolant temperature multiplex signal
DF174 ABS fault detection
DF175 Left-hand FR* wheel multiplex speed signal
DF176 Right-hand FR* wheel multiplex speed signal
DF177 Automatic transmission overheating
Page 17 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-17V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults
DF002
PRESENT
OR
STOREDCOMPUTER
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition has been switched on.
Check that the computer earth is connected correctly to the vehicle's left-hand front side member.
Measure the battery voltage, it should be between 11.8 V and 13.2 V.
Check the cleanliness and condition of the connections.
Check the 20A permanent computer feed fuse F15 on connection BP42 in the Protection and Switching Unit.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the cleanliness and condition of the connections.
Check the 5A computer after ignition feed fuse F5H on connection AP4 in the Protection and Switching Unit.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Disconnect connector PPM2 in the Protection and Switching Unit.
Use the Universal bornier Elé. 1681 to check the insulation, continuity and the absence of interference
resistance on the following connections:
●Connection code BP42 between components 119 and 1337.
●Connection code AP4 between components 119 and 1337.
●Connection code N between components 119 and 107.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the battery.
With the ignition on, check for 12 V on component 119, between the following connections:
●Connection code BP42.
●Connection code AP42.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If 12 V is not found, there is a failure in the Protection and Switching Unit.
Run fault finding on the Protection and Switching Unit.
If the fault is still present, contact the Techline.
DPOTA2000_V10_DF002/DPOTA2000_V11_DF002/DPOTA2000_V15_DF002
MR-372-J84-23A050$330.mif
Page 18 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-18V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF003
PRESENT
OR
STOREDANALOGUE SENSOR SUPPLY
NOTESIf fault DF002 Computer is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the ignition has been switched on.
Disconnect the battery.
Check the condition and cleanliness of the modular connector connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●Connection code 5U between components 119 and 781.
●Connection code 5V between components 119 and 781.
●Connection code 5BC between components 119 and 754.
●Connection code 5BB, between components 119 and 754.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 781 between the following connections:
●Connection code 5U.
●Connection code 5V.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
The value should be approximately 20 kΩ.
If the resistance is not correct, either the sensor or the harness is damaged.
Measure the resistance of component 754 between the following connections:
●Connection code 5BC.
●Connection code 5BB.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
The resistance should be between 2360 and 2660 ΩΩ Ω Ω
at a temperature of approximately 20˚C.
If the resistance is not correct, either the sensor or the harness is damaged.
If the fault is still present, contact the Techline.
If the fault does not disappear, deal with the other faults then go to the conformity check.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF003/DP0TA2000_V11_DF003/DP0TA2000_V15_DF003
Page 19 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-19V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF005
PRESENT
OR
STOREDOIL PRESSURE SENSOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after a timed period of 10 seconds with the engine running
at 2000 rpm.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connection:
●Connection code 5U between components 119 and 781.
●Connection code 5W between components 119 and 781.
●Connection code 5V between components 119 and 781.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 781 between connections 5V and 5W on the computer connector
(female connector).
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Replace the sensor if the resistance is not approximately 20 kΩΩ Ω Ω
.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF005/DP0TA2000_V11_DF005/DP0TA2000_V15_DF005
Page 22 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-22V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF009
CONTINUED 2
Check the insulation of component 485 on the following connections:
Lever in position P
●Connection codes 5DH and 5DK between components 119 and 485.
●Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position N
●Connection codes 5DG and 5DK between components 119 and 485.
●Connection codes 5DJ and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Lever in position D
●Connection codes 5DG and 5DK between components 119 and 485.
●Connection codes 5DH and 5DK between components 119 and 485.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the insulation is faulty, replace the multifunction switch.
Check the cleanliness and condition of the connections.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●Connection code 5DG between components 119 and 485.
●Connection code 5DH between components 119 and 485.
●Connection code 5DJ between components 119 and 485.
●Connection code 5DK between components 119 and 485.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault has still not been solved, deal with the other faults and then proceed to the conformity check.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
Page 23 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-23V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF012
PRESENT
OR
STOREDSOLENOID VALVE SUPPLY
CO.0 : Open circuit or short circuit to earth
CC.1 : Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V of the following
connections:
●Connection code 5AU between components 119 and 754.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF012/DP0TA2000_V11_DF012/DP0TA2000_V15_DF012
Page 24 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-24V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF016
PRESENT
OR
STOREDLOCKUP SOLENOID VALVE CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●Connection code 5BX between components 119 and 754.
●Connection code 5BA between components 119 and 754.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●Connection code 5BX.
●Connection code 5BA.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Replace the solenoid valve or the electro-hydraulic interface wiring if the resistance is not 1 ΩΩ Ω Ω
± 0.12 ΩΩ Ω Ω
at 20˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF016/DP0TA2000_V11_DF016/DP0TA2000_V15_DF016
Page 25 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-25V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF017
PRESENT
OR
STOREDEXCHANGER FLOW RATE SOLENOID VALVE CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after running command AC024 Sequential actuator control.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Repair.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●Connection code 5DN between components 119 and 1019.
●Connection code 5DD between components 119 and 1019.
If the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 1019 between the following connections:
●Connection code 5DN.
●Connection code 5DD.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Replace the exchanger flow solenoid valve or the wiring harness if the resistance is not 40 ΩΩ Ω Ω
± 4 ΩΩ Ω Ω
at 20˚C.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the diagnostic
tool.
DP0TA2000_V10_DF017/DP0TA2000_V11_DF017/DP0TA2000_V15_DF017
Page 28 of 128
AUTOMATIC TRANSMISSION
Fault finding – Interpretation of faults23A
23A-28V4 MR-372-J84-23A050$330.mif
SIEMENS TA2000
Vdiag No.: 10-11-15
DF023
PRESENT
OR
STOREDGEARBOX OIL TEMPERATURE SENSOR CIRCUIT
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special notes:
Use bornier Elé. 1681 for all operations on the computer connectors.
Disconnect the battery.
Disconnect the modular connector, and check the cleanliness and condition of the connections.
Disconnect the computer. Check the cleanliness and condition of the connections.
Repair.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●Connection code 5BC between components 119 and 754.
●Connection code 5BB between components 119 and 754.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Reconnect the modular connector.
Measure the resistance of component 754 between the following connections:
●Connection code 5BC.
●Connection code 5BB.
If the connection(s) are faulty and if there is a repair method (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace the wiring.
Replace the sensor or the wiring if the resistance is not between:
2360 ΩΩ Ω Ω
and 2660 ΩΩ Ω Ω
at 20˚C
290 ΩΩ Ω Ω
and 327 ΩΩ Ω Ω
at 80˚C
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition and carry out a road test followed by a test with the
diagnostic tool.
DP0TA2000_V10_DF023/DP0TA2000_V11_DF023/DP0TA2000_V15_DF023