fuse RENAULT SCENIC 2008 J84 / 2.G Gas Injection LPG 3000 Workshop Manual

Page 4 of 107

17C-4
MR-372-J84-17C000$059.mif
V2
LPG 3000
Program No: AB
Vdiag No: 08/10GAS INJECTION
Fault finding - Introduction17C
4. FAULT FINDING PROCEDURE
Check the battery charge and the
condition of the fuses
Print the system fault finding log
(available on CLIP and in the MR or
Technical Note)
Connect CLIP
no
Dialogue with
computer?
yes
Read faults
no
Faults present
yes
Deal with present faults
Deal with stored faults
no
Is the cause still
present?Fault
solved
yes
See ALP No. 1
Conformity check
no
The cause is still
presentFault
solved
yes
Use fault finding charts (ALPs)
no
The cause is still
presentFault
solved
yes
Contact Techline with the
completed fault finding log

Page 5 of 107

17C-5
MR-372-J84-17C000$059.mif
V2
GAS INJECTION
Fault finding - Introduction
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
4. FAULT FINDING PROCEDURE (continued)
Wiring check
Fault finding problems
Disconnecting the connectors and/or manipulating the wiring harness may temporarily remove the cause of a fault.
Electrical measurements of voltage, resistance and insulation are generally correct, especially if the fault is not
present when the analysis is made (stored fault).
Visual inspection
●look for damaged wiring under the bonnet and in the passenger compartment.
●carefully check the fuses, insulation and the correct routing of the wiring.
●look for signs of oxidation.
Tactile inspection
While manipulating the wiring harness, use the diagnostic tool to note any change in fault status from stored to
present.
●Make sure that the connectors are properly locked.
●Apply light pressure to the connectors.
●Twist the wiring harness.
If there is a change in status, try to locate the source of the fault.
Inspection of each component
●disconnect the connectors and check the appearance of the clips and tabs, as well as the crimping (no
crimping on the insulating section).
●make sure that the clips and tabs are properly locked in the sockets.
●Check that no clips or tabs have been dislodged during connection.
●check the clip contact pressure using an appropriate model of tab.
Resistance check
●check the continuity of the entire lines, then section by section.
●look for a short circuit to earth, to + 12V or with another wire.
If a fault is detected, apply the associated fault finding procedure and repair or replace the wiring.

Page 17 of 107

17C-17
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF007
PRESENT
OR
STOREDMAIN RELAY CIRCUIT
1.DEF: Voltage outside permitted range of values
2.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been started and switched to LPG
mode.
Manipulate the wiring harness between the LPG computer and the main relay in order to produce a change in
status.
Look for any damage to the wiring harness and check the connection and condition of the main relay and its
connections (present ↔ stored).
If necessary, repair or replace the connector.
With the ignition on, check for +12V on track 1 and track 3 of the main relay.
If no + 12 V:
–disconnect the battery,
–in the Protection and Switching Unit, disconnect the grey connector,
–check the cleanliness and condition of the connections,
–Use the universal bornier to check the continuity of the following connection:
For Mégane 2:
Protection and Switching Unit, grey connector, track 1
For Logan:
Fuse box, track S4track 3 of the main relay
track A5 of the main relay
Repair if necessary.
Check the insulation in relation to + 12V and the continuity and absence of interference resistance on
the connection between:
LPG computer track F4 track 2 of the main relay
Repair if necessary.
With the ignition on, check for earth on track 2 of the main relay.
If, with the ignition on, the computer does not control the main relay on track 2 via an earth, contact the Techline.
With the engine running, check that the relay clicks when LPG mode is selected.
Replace the main relay if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF007 / GAZ3000_V10_DF007

Page 20 of 107

17C-20
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF014
PRESENT
OR
STOREDGAUGE SUPPLY CIRCUIT
CC.0: Open circuit or short circuit to earth
CC.1: Short circuit to + 12 volts
NOTESSpecial note:
The system changes to forced petrol mode "LPG system fault" and refuses to change
to LPG mode while the fault is present.
Clear the faults from memory and then start the engine.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF014 / GAZ3000_V10_DF014

Page 25 of 107

17C-25
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF020
PRESENT
OR
STOREDFUEL SENDER SWITCHING RELAY CIRCUIT
CC.1: Short circuit to + 12 Volts
CO.0: Open circuit or short circuit to earth
2.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine is started and switched to LPG mode
or when command AC005 Fuel sender relay is executed.
Manipulate the wiring harness between the LPG computer and the fuel sender relay in order to produce a change
in status (present ↔ stored).
Look for possible damage to the wiring harness and check the connection and condition of the fuel sender relay
and its connections.
Repair if necessary.
Check the continuity and insulation of the following connection:
Fuel sender relay track 5 track E3, LPG computer
Replace the fuse if necessary.
With the ignition on, check for +12V on track C1 of the LPG computer.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
LPG computer track C1 track B1 of the LPG or petrol selector switch
If the fault is still present, check the intermediate connector (R34 on track 7, for Mégane 2 and R212 on
track B6, for Logan).
Repair if necessary.
Check the insulation in relation to earth and the continuity and the absence of interference resistance on
the connection between:
LPG computer track E4 track 2 of the fuel sender relay
Repair if necessary.
In LPG operation, check for earth on track 2 of the fuel sender relay.
If, with the ignition on, the computer does not control the fuel sender relay on track 2 via an earth, contact
the Techline.
If the fault is still present, replace the fuel sender relay.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF020 / GAZ3000_V10_DF020

Page 26 of 107

17C-26
MR-372-J84-17C000$354.mif
V2
GAS INJECTION
Fault finding - Interpretation of faults
LPG 3000
Program No: AB
Vdiag No: 08/10
17C
DF021
PRESENT
OR
STOREDLPG TANK SOLENOID VALVE RELAY CIRCUIT
CC.1: Short circuit to + 12 Volts
CO.0: Open circuit or short circuit to earth
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
If fault DF024 Fuel pump cut-off relay circuit is present or stored, deal with this fault
first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine has been started and switched to LPG
mode.
Manipulate the wiring harness between the LPG computer and the LPG tank solenoid valve relay in order to
produce a change in status (present ↔ stored).
Look for possible damage to the wiring harness and check the condition and connection of the LPG tank
solenoid valve relay and its connections.
If necessary, repair or replace the connector.
With the ignition on, check for + 12V on track 1 of the LPG tank solenoid valve relay and track C2 of the LPG
computer.
If no + 12 V:
–disconnect the battery,
–in the Protection and Switching Unit, disconnect the grey connector,
–check the cleanliness and condition of the connections,
–Use the universal bornier to check the continuity of the following connection:
For Mégane 2:
Protection and Switching Unit, grey connector, track 1
For Logan:
Fuse box, track S4track 3 of the main relay
track A5 of the main relay
Repair if necessary.
Check for + 12V on track 3 of the LPG tank solenoid valve relay.
If + 12V is not present, use the universal bornier to check the continuity of the following connection:
For Mégane 2:
Tank solenoid valve relay track 3
For Logan:
Double control relay unit track B3track 5 of the fuel pump relay
track B5 of the fuel pump relay
Repair if necessary.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
GAZ3000_V08_DF021 / GAZ3000_V10_DF021

Page 99 of 107

17C-99
MR-372-J84-17C000$944.mif
V2
17C
GAS INJECTION
Fault finding - Fault finding chart (ALP)
ALP 1 No dialogue with the computer
NOTESNone.
Check for a + 12 V battery feed on track H4 and a + 12 V after ignition feed (using the forced + after ignition
mode, see Introduction section) on track C2 of the LPG computer.
Repair if necessary.
Check the condition of the battery and the vehicle earths.
Repair if necessary.
Try the diagnostic tool on another vehicle.
–check the connection between the diagnostic tool and the diagnostic socket (lead in good condition),
–check fuse F5 (15 A) (for Mégane 2) and fuses F04 (10A) and F29 (15A) (for Logan).
Repair if necessary.
Check the insulation, continuity and the absence of interference resistance on the connections between:
LPG computer track H1
LPG computer track G1
LPG computer track B4Earth
Earth
track 7 of the diagnostic socket
Repair if necessary.
Use the diagnostic socket to check the following tracks:
Track 1
Track 16
Tracks 4 and 5+ After ignition
+ Battery
Earth
Repair if necessary.
AFTER REPAIRCheck using the diagnostic tool.
GAZ3000_V08_ALP1 / GAZ3000_V10_ALP1
LPG 3000
Program No: AB
Vdiag No: 08/10
MR-372-J84-17C000$944.mif