heater RENAULT SCENIC 2008 J84 / 2.G Passenger Comparment Connection Unit Workshop Manual

Page 126 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -126
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -126V9 MR-372-J84-87B000$387.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
FUNCTION: AIR CONDITIONING
Sub-function: User selection
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application condition: engine stopped, + after ignition feed present.
Sub-
functionParameter or
Status
checked Action Display and Notes Fault finding
User
selectionET029:Air conditioning
buttonDEPRESSED
RELEASED In the event of a fault,
refer to the
interpretation of status
ET029.
ET028:Heated rear screen
buttonPRESSED if the "heated rear
screen" button on the air
conditioning control panel is
pressed.
RELEASED otherwise.In the event of a fault,
refer to the
interpretation of status
ET028.
ET015:Passenger
compartment blowerACTIVE
INACTIVE
Note:
This status is only operative
for manual air conditioning
systems (and heater versions
without air conditioning).In the event of a fault,
refer to the
interpretation of status
ET015.

Page 127 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -127
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -127V9 MR-372-J84-87B000$387.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
FUNCTION: AIR CONDITIONING
Sub-function: Heating
*RCH = Passenger Compartment Heating Resistor
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application condition: engine stopped, + after ignition feed present.
Sub-
functionParameter or
Status
checked Action Display and Notes Fault finding
HeatingPR001:Battery voltage9 V < X < 16 V In the event of a fault,
consult the
interpretation of
parameter PR001.
PR002:External
temperature Temperature in ˚CIn the event of a fault,
consult the
interpretation of
parameter PR002.
ET017:Number of RCH*
required0, 1, 2, 3, 4 or 5In the event of a fault,
consult the
interpretation of status
ET017.
ET018:Number of RCH*
authorised by
alternator0, 1, 2, 3, 4 or 5In the event of a fault,
consult the
interpretation of
status ET018.
ET019:Number of RCH*
authorised by
injection computer0, 1, 2, 3, 4 or 5In the event of a fault,
consult the
interpretation of status
ET019.
ET015:Passenger
compartment fan ACTIVE
INACTIVE
Note:
This status is only operative
for manual air conditioning
systems (and heater versions
without air conditioning). In the event of a fault,
refer to the
interpretation of status
ET015.

Page 129 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -129
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Conformity check
87B
87B -129V9 MR-372-J84-87B000$387.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
FUNCTION: AIR CONDITIONING
Sub-function: Cold Loop
NOTESOnly carry out this conformity check after a complete check with the diagnostic tool
(fault reading and configuration checks).
Application condition: engine stopped, + after ignition feed present.
Sub-
functionParameter or
Status
checked Action Display and Notes Fault finding
Cold loopET030:Air conditioning
request 2ACTIVE
INACTIVEIn the event of a fault,
consult the
interpretation of status
ET030.
ET169:EngineSTOPPEDIn the event of a fault,
refer to the
interpretation of
status ET169.
ET015:Passenger
compartment fan ACTIVE
INACTIVE
Note:
This status is only operative
for manual air conditioning
systems (and heater versions
without air conditioning). In the event of a fault,
refer to the
interpretation of status
ET015.
PR002:External
temperature Temperature in ˚CIn the event of a fault,
consult the
interpretation of
parameter PR002.

Page 150 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of statuses
87B
87B -150
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of statuses
87B
87B -150V9 MR-372-J84-87B000$473.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
*RCH = Passenger Compartment Heating ResistorET020
NUMBER OF RCH* CONTROLLED
NOTESThere must be no present or stored faults.
The maximum number of passenger compartment heating resistors controlled will be
the minimum number indicated by statuses ET017, ET018, ET019.
Special note:
The UCH controls the passenger compartment heating resistor relays according to the
authorisation from the injection computers and Protection and Switching Unit.
The status, depending on the conditions, will be 0, 1, 2, 3, or 4.
The passenger compartment heating resistor control conditions are:
–Heater motor running.
–Battery voltage > 12 V.
–Interior temperature < 10˚C.
–User temperature setpoint in warm position (> 20˚C).
–PR002 External temperature < 5˚C.
–ET015 Passenger compartment fan ACTIVE.
–ET018 Number of RCHs authorised by alternator > 0.
–ET019 Number of RCH* authorised by injection computer > 0.
–PR010 (UPC) Alternator charge < 70%.
If all the conditions are satisfied, and depending on the air conditioning function program, the UCH controls the
Passenger Compartment Heating Resistors needed to provide the service.
Check that these statuses and parameters are working properly.
In the event of a fault, refer to the interpretation of these statuses and parameters.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_ET020/UCH_V48_ET020/ UCH_V4C_ET020/
UCH_V4D_ET020 /UCH_V4F_ET020/UCH_V50_ET020

Page 151 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of statuses
87B
87B -151
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of statuses
87B
87B -151V9 MR-372-J84-87B000$473.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
*RCH = Passenger Compartment Heating ResistorET021
ET022
ET023
RCH* 1 RELAY CONTROL
RCH* 2 RELAY CONTROL
RCH* 3 RELAY CONTROL
NOTESThere must be no present or stored faults.
For statuses ET021 and ET022, the signal can be interpreted if the vehicle is
configured with 1000 W Passenger Compartment Heating Resistors or 1800 W
Passenger Compartment Heating Resistors.
For status ET023, the signal is interpretable if the vehicle is configured with RCH
1800 W.
In the event of a fault, check the operation of statuses ET015 Passenger compartment fan, ET017 Number of
RCH* required, ET018 Number of RCH* authorised by alternator, ET019 Number of RCH* authorised by
injection and ET020 Number of RCH* controlled.
Carry out fault finding on commands AC016 RCH* relay 1, AC017 RCH* relay 2 and AC018 RCH* relay 3.
Check the parameters needed to switch on the Passenger Compartment Heating Resistors; exterior temperature,
interior temperature, temperature setpoint on the heater control panel, alternator load, battery voltage.
If all the requisite conditions are consistent and the status remains INACTIVE, contact Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.
UCH_V44_ET021/UCH_V48_ET021/ UCH_V4C_ET021/UCH_V4D_ET021/ UCH_V4F_ET021/UCH_V50_ET021/
UCH_V44_ET022/UCH_V48_ET022/ UCH_V4C_ET022/UCH_V4D_ET022/ UCH_V4F_ET022/UCH_V50_ET022/
UCH_V44_ET023/UCH_V48_ET023/ UCH_V4C_ET023/UCH_V4D_ET023/ UCH_V4F_ET023/UCH_V50_ET023

Page 257 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 257
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 257V9 MR-372-J84-87B000$774.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
AC015
AIR-CONDITIONING BUTTON INDICATOR LIGHT
Manual air conditioning only
NOTESNo faults should be present or stored.
This command is for testing operation of the air-conditioning indicator light.
Apply the after ignition feed, and the air conditioning control panel should light up.
The command lasts 7 seconds.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
The indicator light does not light up when the command is activated.
Check the condition and connection of the heater control panel connector.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check for earth on connection NAM of component 316.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
With the command running, check for + 12 V feed on connection 38ES of component 316.
If OK, replace the control panel.
Check the condition and connection of connector PE2 on the UCH
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connection:
●Connection code 38ES between components 645 and 319.
●Connection code NAM between component 319 and earth.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.

Page 264 of 391

PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 264
PASSENGER COMPARTMENT CONNECTION UNIT
Fault finding - Interpretation of commands87B
87B - 264V9 MR-372-J84-87B000$774.mif
UCH
Vdiag No.: 44, 48,
4C, 4D, 4F, 50
AC019
HEATED REAR SCREEN INDICATOR LIGHT
Except with climate control
NOTESNo faults should be present or stored.
This command is for testing operation of the heated rear screen indicator light.
Apply after ignition feed.
The command lasts 7 seconds.
Use Wiring Diagrams Technical Note for MEGANE II or SCENIC II.
The heated rear screen indicator light does not light up when the command is activated.
Check the condition and connection of the heater control panel connector.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check for earth on connection NAM of component 319.
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
With the command running, check for + 12 V feed on connection 15A of component 316.
If OK, replace the control panel.
Check the condition and connection of connector PE2 on the UCH
If the connector is faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the connector; otherwise, replace the wiring.
Check the insulation and continuity of the following connection:
●Connection code 15A between components 645 and 319.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact Techline.
AFTER REPAIRCarry out another fault finding check on the system.
Clear the stored faults.
Deal with any other faults.