RENAULT SCENIC 2010 J95 / 3.G Petrol Injection S3000 Injection Workshop Manual

Page 101 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-101
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-101V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF404
PRESENT
OR
STORED
AUTOMATIC TRANSMISSION OR SEQUENTIAL GEARBOX CAN
CONNECTION
1.DEF: Incorrect gear
2.DEF: Incorrect torque signal from automatic gearbox computer
3.DEF: No multiplex frames or invalid values (fault on computer transmitting signal
or CAN connection)
NOTESPriority when dealing with a number of faults:
If fault DF046 Battery voltage is present or stored, deal with this first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Run a multiplex network test (See88B, Multiplex).
If the fault is still present, run fault finding on the automatic gearbox (see 23A, Automatic gearbox).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF404/S3000_V54_DF404

Page 102 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-102
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-102V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF410
PRESENT
OR
STOREDINSTRUMENT PANEL CONNECTION
1.DEF: Multiplex line connection fault
NOTESSpecial note:
– Cruise control/Speed limiter deactivated.
–OBD warning light not illuminated when ignition switched on.
Run a multiplex network test (see88B, Multiplexing).
If the fault is still present, carry out fault finding on the Instrument panel system (see83A, Instrument panel).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF410/S3000_V54_DF410

Page 103 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-103
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-103V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF436
PRESENT
OR
STOREDDETECTION OF ENGINE MISFIRING
1.DEF: Destructive misfiring
2.DEF: Pollutant misfiring
3.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– ignition:
DF361 Ignition coil circuit cylinders 1-4,
DF362 Ignition coil circuit cylinders 2-3.
– fuel supply circuit:
DF026 Cylinder 1 injector control circuit,
DF027 Cylinder 2 injector control circuit,
DF028 Cylinder 3 injector control circuit,
DF029 Cylinder 4 injector control circuit,
DF085 Fuel pump relay control circuit.
– flywheel signal:
DF154 Flywheel signal sensor circuit,
DF457 Engine flywheel target.
– cylinder combustion misfires:
DF059 Combustion misfire in cylinder 1,
DF060 Combustion misfire in cylinder 2,
DF061 Combustion misfire in cylinder 3,
DF062 Combustion misfire in cylinder 4.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– engine warm (min 75°C),
– engine running at idling speed with all electrical consumers on for approximately
15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then
is continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF436/S3000_V54_DF436

Page 104 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-104
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-104V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF436
CONTINUED
Check the injectors.
Check the condition and conformity of the spark plugs.
Check the ignition pencil coils.
Check that the correct fuel is being used.
If the fault is still present, carry out the following checks:
– check the flywheel sensor,
– check the condition and cleanliness of the flywheel,
– check the flywheel sensor mounting,
– check the sensor/flywheel air gap,
– check the cylinder compressions,
– check the complete fuel supply system (see Workshop Repair Manual 364 or 370 Mechanics, 13A, Fuel
supply),
– check the complete ignition system (see MR 364 or 370 Mechanics, 17A, Ignition),
– check the hydraulic tappets if there is camshaft noise (see MR 364 or 370 Mechanics, 11A, Top and front of
engine).
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.

Page 105 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-105
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-105V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF455
PRESENT
OR
STOREDLOW FUEL LEVEL SIGNAL
1.DEF: Multiplex network
2.DEF: Non-compliance with emission control standards
NOTESNone.
Run a multiplex network test (see88B, Multiplexing).
If the fault is still present, carry out fault finding on the Instrument panel system (see83A, Instrument panel).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF455/S3000_V54_DF455

Page 106 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-106
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-106V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF457
PRESENT
OR
STOREDFLYWHEEL TARGET
1.DEF: Component in bad condition
2.DEF: Non-compliance with emission control standards
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special note:
–OBD warning light illuminated.
Check the cleanliness and condition of the engine flywheel.
Repair or replace the engine flywheel if necessary.
If the flywheel has been replaced or removed, the flywheel ring has to be reinitialised, then reprogrammed.
Reinitialise programming:
Use command RZ005: Programming.
Carrying out the flywheel target programming:
– Decelerate a first time with injection cut-off (i.e. feet off the brake, accelerator pedal and clutch pedals) between
3500 and 3000 rpm, in 3rd gear for a manual gearbox and 2nd for automatic gearbox, for at least 5 seconds.
– Decelerate a second time with injection cut-off (i.e. brake, accelerator and clutch pedals released) between
2400and 2000 rpm for K4 engines and between 1800 and
1400 rpm for F4R engines, in 3rd gear for a manual gearbox and 2nd for an automatic gearbox, for at least
5 seconds.
After the operation, check that status ET089 Flywheel target programming is COMPLETED.
(*This is the moment when, during deceleration with no load, the engine drops to idle speed and recovers torque).
If the fault is still present, contact the Techline.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF457/S3000_V54_DF457

Page 107 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-107
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-107V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF570
PRESENT
OR
STOREDCOOLANT PUMP RELAY
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short-circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the engine is running or on command AC195
Electric coolant pump.
Check the cleanliness, condition and fitting of the coolant pump.
Top up the coolant if necessary.
If the fault is still present, manipulate the harness to see if the status changes.
Look for any harness damage, and check the condition and connection points of the injection computer and the
coolant pump connectors.
Repair if necessary.
If the fault is still present, check for +12V on track 2 of the coolant pump.
If +12V is not present on track 2 of the coolant pump, check the following connection for insulation, continuity
and the absence of interference resistance:
Coolant pump track 2 track 6, connector CN, of the Protection and
Switching Unit
Repair if necessary.
If the fault is still present, check the insulation, continuity and the absence of interference resistance on the
following connection:
Computer, connectorB, track L4 track 1 of the coolant pump
Repair if necessary.
If the fault is still present, check that the resistance between tracks 1 and 2 of the coolant pump is neither zero
nor infinite.
Replace the coolant pump if necessary.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF570/S3000_V54_DF570

Page 108 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-108
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-108V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF601
PRESENT
OR
STOREDUPSTREAM O2 SENSOR HEATING POWER CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with faults DF046 Battery voltage or DF084
Actuators relay control circuit first if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a delay of 10 seconds with the engine running or
when command AC018 Upstream O2 sensor heating is activated.
Special note:
–OBD warning light illuminated.
CO/CC.1: Upstream O
2 sensor heating no longer working.
CO.1: Upstream O
2 sensor heating on permanently as soon as the ignition is switched
on: risk of irreparable damage to the sensor.
Check the cleanliness and condition of the upstream oxygen sensor connections.
Repair if necessary.
With the ignition on, check for + 12 V on track A of the upstream oxygen sensor connector.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorB, track M2 track A of the upstream oxygen sensor
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorC, track L2 track B of the upstream oxygen sensor
Repair if necessary.
Measure the heating resistance between tracks A and B of the upstream oxygen sensor.
Replace the upstream oxygen sensor if the resistance is not 9Ω ± 0.5Ω at 20°C.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF601/S3000_V54_DF601

Page 109 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-109
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-109V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF602
PRESENT
OR
STOREDDOWNSTREAM O2 SENSOR HEATING POWER CIRCUIT
CO.0: Open circuit or short circuit to earth
CC.1: Short-circuit to + 12 V
1.DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
Apply the procedure for dealing with faults DF046 Battery voltage or DF084
Actuators relay control circuit first if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after a delay of 10 seconds with the engine running or
when command AC019 Downstream O2 sensor heating is activated.
Special note:
–OBD warning light illuminated.
CO/CC.1: Downstream O
2 sensor heating no longer working.
CO.1: Downstream O
2 sensor heating on permanently as soon as the ignition is
switched on: risk of irreparable damage to the sensor.
Check the cleanliness and condition of the downstream oxygen sensor connections.
Repair if necessary.
Check for + 12 V on track A of the downstream oxygen sensor connector with the ignition on.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connectorB, track M2 track A of the downstream oxygen sensor
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Computer, connector C, track L3 track Bof the downstream oxygen sensor.
Repair if necessary.
Measure the heating resistance between tracks A and B of the downstream oxygen sensor.
Replace the downstream oxygen sensor if the resistance is not 9Ω ± 0.5Ω at 20°C.
If the fault is still present, deal with the other faults then proceed with the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF602/S3000_V54_DF602

Page 110 of 230

PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-110
PETROL INJECTION
Fault finding - Interpretation of faults
17B
17B-110V9 MR-372-J84-17B050$423.mif
S3000 Injection
Program No.: AD
Vdiag No.: 4C / 54
DF623
PRESENT
OR
STOREDCLOSING BRAKE SIGNAL
1.DEF: Multiplex line connection fault
NOTESSpecial note:
– cruise control and speed limiter deactivated.
Check the condition and cleanliness of the pedals.
Check the cleanliness and condition of the dual-contact brake and its connections.
Repair if necessary.
With the ignition on, check for + 12 V on tracks B1 and A1, of the brake pedal switch connector.
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Use the "Universal bornier" to check the insulation and continuity on the following connection:
Injection computer, connector A, track E3 Track B3 of the brake pedal
Repair if necessary.
Run a multiplex network test (see88B, Multiplex).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V4C_DF623/S3000_V54_DF623