RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Injection Repair Manual

Page 51 of 236

DIESEL INJECTION
Fault finding - Interpretation of faults13B
13B-51V10 MR-372-J84-13B150$282.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF038
CONTINUED
10.DEF
NOTESIf there are a number of faults, deal with the other system
faults first.
NODisplay the stored context for fault DF038.
PR142 Computer fault = 10YES
Contact the Techline
NOParameters of main screen PR071 Computer
supply voltage > 10 V.YES
NOContexts stored for DF038
PR071 Computer supply voltage > 10 V.
YES
– Check the condition of the wiring harness
between the computer and the battery, carry
out the necessary repairs.
– Start the vehicle.
– Clear the stored faults.
– Check the faults:
– If DF038 is absent, end of fault finding.
– If DF038 is present, contact the Techline.
– Check the charge circuit and carry out the
necessary repairs:
– Check the condition of the battery terminals,
– Carry out fault finding on the alternator.
Recharge or replace the battery.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.

Page 52 of 236

13B-52
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$282.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF039
PRESENT
OR
STOREDINLET AIR TEMPERATURE SENSOR CIRCUIT
CO.1 : open circuit or short circuit to + 12 V
CC.0 : short circuit to earth
1.DEF : below minimum threshold
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after an attempted start, or with the engine running
following a road test.
Special notes:
If the fault is present:
– The air temperature value enters defect mode, i.e. PR059 Intake air
temperature = 20°C.
– The EGR function is inhibited.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
CO.1
NOTESNone.
Check the air flowmeter connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity of the following connection:
Air flowmeter black 6-track connector track 4 Track 2 UPC black connector
Repair if necessary.
Check the continuity and insulation against + 12 V of the following connections:
Injection computer brown 48-track connector B, track G2 Track 1 air flowmeter connector
Injection computer brown 48-track connector B, track E2 Track 2 air flowmeter connector
Repair if necessary.
Measure the air temperature sensor resistance between tracks 1 and 2 of the air flow sensor.
Replace the air flowmeter if the resistance is not: 3714Ω ±161 at + 10°C
2488 Ω ± 90 at 20°C
1671 Ω ± 59 at 30°C
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF039/EDC16_V48_DF039/EDC16_V4C_DF039

Page 53 of 236

13B-53
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$282.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF039
CONTINUED 1
CC.0
NOTESNone.
Check the air flowmeter connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and insulation against earth of the following connections:
Injection computer brown 48-track connector B, track G2 Track 1 air flowmeter
Air flowmeter black 6-track connector track 4 Track 2 UPC black connector
Injection computer brown 48-track connector B, track B4 Track 3 air flowmeter
Repair if necessary.
Measure the resistance of the air temperature sensor integrated into the flowmeter across tracks 1 and 2.
Replace the air flowmeter if the resistance is not: 3714Ω ±161 at + 10°C
2488 Ω ± 90 at 20°C
1671 Ω ± 59 at 30°C
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.

Page 54 of 236

13B-54
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$282.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF039
CONTINUED 2
1.DEF
NOTESNone.
Check the air flowmeter connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and absence of interference resistance of the following connections:
Injection computer brown 48-track connector B, track E2 Track 2 air flowmeter
Injection computer brown 48-track connector B, track G2 Track 1 air flowmeter
Repair if necessary.
Measure the resistance of the air temperature sensor integrated into the flow sensor between tracks 1 and 2.
Replace the air flowmeter if the resistance is not: 3714Ω ±161 at + 10°C
2488 Ω ± 90 at 20°C
1671 Ω ± 59 at 30°C
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.

Page 55 of 236

13B-55
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4CDIESEL INJECTION
Fault finding - Interpretation of faults
DF040
PRESENT
OR
STOREDCYLINDER 1 INJECTOR CIRCUIT
CC.1 : short circuit to + 12 V
CO : open circuit
CC : short circuit
1.DEF : Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CC.1, CC, or 1.DEF is present, the level 2 warning light is lit.
If CO is present the level 1 warning light is lit.
If CO is still present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds + switch off the ignition and wait 40 seconds.).
If the fault is present, the injection on cylinder 1 is disabled.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone.
Check the connections on injector no 1.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 1.
Measure the resistance of injector no. 1 between tracks 1 and 2.
Replace the injector if there is a short circuit (R = 0Ω) or an open circuit (infinite resistance measurement).
Otherwise, reconnect injector no. 1.
Check the continuity and the absence of interference resistance of the following connections:
Injection computer grey 32-track connector C, track G3 Track 2 injector no. 1
Injection computer grey 32-track connector C, track H1 Track 1 injector no. 1
If the fault is still present: run test 1 INJECTOR TEST.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF040/EDC16_V48_DF040/EDC16_V4C_DF040
MR-372-J84-13B150$329.mif

Page 56 of 236

13B-56
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF041
PRESENT
OR
STOREDCYLINDER 2 INJECTOR CIRCUIT
CC.1 : short circuit to + 12 V
CO : open circuit
CC : short circuit
1.DEF : Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CC.1, CC, or 1.DEF is present, the level 2 warning light is lit.
If CO is present the level 1 warning light is lit.
If CO is still present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds + switch off the ignition and wait 40 seconds.).
If the fault is present, the injection on cylinder 1 is disabled.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone.
Check the connections on injector no. 2.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 2.
Measure the resistance of injector no. 2 across tracks 1 and 2.
Replace the injector if there is a short circuit (R = 0Ω) or an open circuit (infinite resistance measurement).
Otherwise, reconnect injector no. 2.
Check the continuity and the absence of interference resistance of the following connections:
Injection computer grey 32-track connector C, track G4 Track 2 injector no. 2
Injection computer grey 32-track connector C, track G2 Track 1 injector no. 2
If the fault is still present: run test 1 INJECTOR TEST.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF041/EDC16_V48_DF041/EDC16_V4C_DF041

Page 57 of 236

13B-57
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF042
PRESENT
OR
STOREDCYLINDER 3 INJECTOR CIRCUIT
CC.1 : short circuit to + 12 V
CO : open circuit
CC : short circuit
1.DEF : Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CC.1, CC, or 1.DEF is present, the level 2 warning light is lit.
If CO is present the level 1 warning light is lit.
If CO is still present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds + switch off the ignition and wait 40 seconds.).
If the fault is present, the injection on cylinder 1 is disabled.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone.
Check the connections on injector no. 3.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 3.
Measure the resistance of injector no. 3 between tracks 1 and 2.
Replace the injector if there is a short circuit (R = 0Ω) or an open circuit (infinite resistance measurement).
Otherwise, reconnect injector no. 3.
Check the continuity and the absence of interference resistance of the following connections:
Injection computer grey 32-track connector C, track H4 Track 2 injector no. 3
Injection computer grey 32-track connector C, track H2 Track 1 injector no. 3
If the fault is still present: run test 1 INJECTOR TEST.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF042/EDC16_V48_DF042/EDC16_V4C_DF042

Page 58 of 236

13B-58
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF043
PRESENT
OR
STOREDCYLINDER 4 INJECTOR CIRCUIT
CC.1 : short circuit to + 12 V
CO : open circuit
CC : short circuit
1.DEF : Injector control
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine has been started.
Special notes:
If CC.1, CC, or 1.DEF is present, the level 2 warning light is lit.
If CO is present the level 1 warning light is lit.
If CO is still present, the OBD warning light will come on after three consecutive driving
cycles (starting + 5 seconds + switch off the ignition and wait 40 seconds.).
If the fault is present, the injection on cylinder 1 is disabled.
Use bornier Elé. 1681 for all operations on the injection computer connectors.
WARNING
This fault may appear if the wiring harness has been damaged.
Follow the procedure described in the Wiring Check in the Introduction.
This test enables the condition and the conformity of the engine wiring harness to be checked.
CC.1
CO
CC
1.DEF
NOTESNone.
Check the connections on injector no 4.
Check the injection computer connections.
Repair if necessary.
Disconnect injector no. 4.
Measure the resistance of injector no. 4 between tracks 1 and 2.
Replace the injector if there is a short circuit (R = 0Ω) or an open circuit (infinite resistance measurement).
Otherwise, reconnect injector no. 4.
Check the continuity, and the absence of resistance of the following connections:
Injection computer grey 32-track connector C, track H3 Track 2 injector no. 4
Injection computer grey 32-track connector C, track G1 Track 1 injector no. 4
If the fault is still present: run test 1 INJECTOR TEST.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF043/EDC16_V48_DF043/EDC16_V4C_DF043

Page 59 of 236

13B-59
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF046
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF : excess voltage
2.DEF : undervoltage
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present following a road test or after attempting to start the engine.
Special notes:
Computer operating voltage: 9 V < operating voltage < 16 V.
If the battery voltage is too low this may cause the level 1 fault warning light to
come on.
It is then not possible to start the engine.
Use bornier Ele. 1681 for all operations on the injection computer connectors.
1.DEF
NOTESNone.
Check the charge circuits: – battery status,
– alternator status (complete fault finding procedure).
Carry out the necessary repairs.
2.DEF
NOTES(Use the Wiring Diagrams Technical Note for the vehicle).
With the ignition off, measure the voltage across the battery terminals.
If the voltage is less than 11.5 V, test the battery.
If the battery is faulty, replace the battery then test the charge circuit.
With the ignition on and the with the starter motor turning, measure the voltage between the battery terminals
If the voltage drops below 9.6 V, check the tightness and condition of the battery terminals.
Repair if necessary.
If the terminals are in good condition, test the battery.
If they are faulty, replace the battery.
If the starter is cranking the engine correctly, but the fault is still present,
–Check the continuity and absence of interference resistance of the following connections:
+ 12 V timed by UPC Track M2 connector B of the engine management computer
+ 12 V timed by UPC Track G1 connector A of the engine management computer
Battery earth Tracks G4, H4, H1 of connectorA of the injection computer
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF046/EDC16_V48_DF046/EDC16_V4C_DF046

Page 60 of 236

13B-60
DIESEL INJECTION
Fault finding - Interpretation of faults13B
V10 MR-372-J84-13B150$329.mif
EDC16 INJECTION
Program No.: C1
Vdiag No.: 44, 48 and 4C
DF047
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after several starting attempts, or with the engine running.
Special notes:
Computer operating voltage: 9 V < operating voltage < 16 V.
If the battery voltage is too low this may cause the level 1 fault warning light to
come on.
It is then not possible to start the engine.
Use bornier Elé. 1681 for all operations on the injection computer connectors.
Check for continuity and the absence of interference resistance on the following connection:
Injection computer connector A, black 32-track track D1 Track 1 black connector of the UPC
Repair if necessary.
Check the condition of the FD5 fuse on the UPC (poor contact, or oxidation on the relay mounting clips).
Repair if necessary.
If the fault does not recur, start the engine and wait 1 min.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by a check with the diagnostic tool.
EDC16_V44_DF047/EDC16_V48_DF047/EDC16_V4C_DF047