RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Workshop Manual

Page 121 of 365

13B-121
MR-372-J84-13B200$324.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF238
PRESENT
OR
STOREDTHERMOPLUNGER NO.3 RELAY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is displayed as present following an engine start or following actuator
command AC031 Thermoplunger relay no. 3.
If faults DF239 “Thermoplunger relay No. 2 circuit” and DF240 “Thermoplunger
relay No. 1 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R5, component code 1069 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors of thermoplunger no.3 relay (R5) and of the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R5, component code 1069.
Replace if defective.
Check the continuity and absence of interference resistance on connection 3JAB between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF238/EDC16_V1C_DF238/EDC16_V20_DF238EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20

Page 122 of 365

13B-122
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF238
CONTINUED 1
CC.0
NOTESNone
Check the condition and correct operation of relay R5, component code 1069.
Replace if defective.
Check the continuity, absence of interference resistance and insulation to earth of connection 3FB between
components 1069 and 983.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.1
NOTESNone.
Check the condition and correct operation of relay R5, component code 1069.
Replace if defective.
Check the continuity and insulation from + 12 V of connection 3JAB between components 597 and 120.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.

Page 123 of 365

13B-123
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF239
PRESENT
OR
STOREDTHERMOPLUNGER RELAY CIRCUIT N° 2
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after an engine start or actuator command AC064 Thermoplunger
no. 2 relay.
If faults DF238 “Thermoplunger relay No. 3 circuit” and DF240 “Thermoplunger
relay No. 1 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R11, component code 1068 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors on thermoplunger no. 2 relay (R11) and on the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R11, component code 1068.
Replace if defective.
Check the continuity and absence of interference resistance on connection 3JAA between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF239/EDC16_V1C_DF239/EDC16_V20_DF239

Page 124 of 365

13B-124
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF239
CONTINUED
CC.0
NOTESNone
Check the condition and correct operation of relay R1, component code 1068.
Replace the relay if necessary.
Check the insulation to earth of connection 3FB between components 1068 and 983.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.1
NOTESNone.
Check the condition and correct operation of relay R11, component code 1068.
Replace if defective.
Check the continuity and insulation from + 12 V of connection 3JAA between components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.

Page 125 of 365

13B-125
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF240
PRESENT
OR
STOREDTHERMOPLUNGER N° 1 RELAY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after the engine is started or after actuator command AC063
Thermoplunger no. 1 relay.
If faults DF238 “Thermoplunger relay No. 3 circuit” and DF239 “Thermoplunger
relay No. 2 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R1, component code 1067 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors on thermoplunger no. 1 relay (R1) and on the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R1, component code 1067.
Replace if defective.
Check the continuity and absence of interference resistance of connection 3JA between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF240/EDC16_V1C_DF240/EDC16_V20_DF240

Page 126 of 365

13B-126
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF240
CONTINUED
CC.0
NOTESNone
Check the condition and correct operation of relay R1, component code 1067.
Replace if defective.
Check the insulation to earth of connection 3FB between components 1067 and 983.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
CC.1
NOTESNone.
Check the condition and correct operation of relay R1, component code 1067.
Replace if defective.
Check the continuity and insulation from + 12 V of connection 3JA between components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.

Page 127 of 365

13B-127
MR-372-J84-13B200$360.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF250
PRESENT
OR
STOREDELECTRONIC STABILITY PROGRAM FUNCTION
1.DEF: Inconsistent signal
2.DEF: Multiplex line connection fault
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present during a road test.
Special notes:
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
Check the ABS computer connections.
Check the injection computer connections.
Repair if necessary.
Run fault finding on the multiplex network (see 88B, Multiplexing) and on the ABS (see 38C, Anti-lock braking
system).
Refer to the Technical Notes for the vehicle when dealing with any faults.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF250/EDC16_V58_DF250/EDC16_V5C_DF250/EDC16_V18_DF250/EDC16_V1C_DF250/EDC16_V20_DF250EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
MR-372-J84-13B200$360.mif

Page 128 of 365

13B-128
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF272
PRESENT
OR
STOREDEGR VALVE CONTROL CIRCUIT
1.DEF: Valve jammed open
2.DEF: Valve jammed closed
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special notes:
The EGR function is inhibited if several faults are present with DF226 Damper valve
circuit.
If 1.DEF is present:
– the level 1 warning light is lit,
– the vehicle performance is reduced,
– there is smoke coming from the exhaust.
Use bornier Elé.1681 or Elé.1590 for any operation on the injection computer
connectors.
1.DEF
2.DEF
NOTESNone
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
Check the continuity and absence of interference resistance of the following connections:
– connection code 3VP,
– connection code 3VQ.
between components 120 and 1460.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check that there are no leaks on the EGR circuit, pierced or damaged pipes, and the tightness of the clips.
Measure the resistance of the EGR valve motor between connections 3VP and 3VQ.
Replace the EGR valve if the resistance displayed is not between 1 Ω < X < 400 Ω at 20°C.
If the valve is jammed or irrevocably seized, replace the EGR valve.
Run command SC036 Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets (see
Replacement of components).
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF272/EDC16_V58_DF272/EDC16_V5C_DF272/EDC16_V18_DF272/EDC16_V1C_DF272/EDC16_V20_DF272

Page 129 of 365

13B-129
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF276
PRESENT
INJECTOR CODE PROGRAMMING
1.DEF: Internal electronic fault when writing
2.DEF: No code stored
NOTESCondition for applying fault finding ONLY to a present fault:
The fault is declared present after:
– reprogramming the injection computer,
– replacing and programming the injection computer.
Special notes:
If the fault is present:
– the engine speed is limited,
– the level 1 warning light is illuminated.
1.DEF
NOTESNone
Enter the injector codes using command SC002 Enter injector codes (see Interpretation of commands).
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establishing dialogue.
Refer to the interpretation of command SC002 Enter injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed)
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 “Use of injector codes” becomes “YES”, fault DF276 is present and the engine
operates in defect mode.
Program the injector codes using command SC002 Enter injector codes (see Interpretation of commands).
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establishing dialogue, refer
to interpretation of command SC002 Enter injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF276/EDC16_V58_DF276/EDC16_V5C_DF276/EDC16_V18_DF276/EDC16_V1C_DF276/EDC16_V20_DF276

Page 130 of 365

13B-130
MR-372-J84-13B200$360.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20,
50, 58, 5C
13B
DF308
PRESENT
OR
STOREDCLOGGED PARTICLE FILTER
1.DEF: Maximum limit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after the engine is started or following a road test.
Special notes:
If the fault is present:
– particle filter regeneration is inhibited,
– the EGR function is inhibited,
– the vehicle performance is reduced,
– the level 1 warning light is illuminated and a warning message or a special particle
filter warning light is displayed on the instrument panel.
Use bornier Ele. 1681 for all operations on the engine management computer
connector.
Priorities when dealing with a number of faults:
Firstly, deal with the following faults:
– DF315 Particle filter differential pressure sensor if it is present.
– DF308 if DF315 is stored.
– DF226 Damper valve circuit if it is present or stored.
– DF272 EGR valve control circuit if it is present or stored.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V50_DF308/EDC16_V58_DF308/EDC16_V5C_DF308/EDC16_V18_DF308/EDC16_V1C_DF308/EDC16_V20_DF308

Page:   < prev 1-10 ... 81-90 91-100 101-110 111-120 121-130 131-140 141-150 151-160 161-170 ... 370 next >