fuses RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16 Workshop Manual

Page 4 of 365

13B-4
MR-372-J84-13B200$036.mif
V13
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5CDIESEL INJECTION
Fault finding – Introduction13B
3. FAULT FINDING PROCEDURE
* Check the battery charge, the condition of the fuses and the level of the fuel in the tank.
Perform a pre-diagnostic on the
system
Print the system fault finding log
(available on CLIP and in the
Workshop Repair Manual or
Technical Note)
Connect CLIP
no
Dialogue with
computer?
yes
Read the faults
no
Faults
present
yes
Deal with present faults
Deal with stored faults
no
The cause is
still presentFault
solved
yes
See ALP no. 1
Conformity check
no
The cause is
still presentFault
solved
Use fault finding charts
(ALPs)
no
The cause is
still presentFault
solved
Contact the Techline with the
completed fault finding log

Page 121 of 365

13B-121
MR-372-J84-13B200$324.mif
V13
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF238
PRESENT
OR
STOREDTHERMOPLUNGER NO.3 RELAY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is displayed as present following an engine start or following actuator
command AC031 Thermoplunger relay no. 3.
If faults DF239 “Thermoplunger relay No. 2 circuit” and DF240 “Thermoplunger
relay No. 1 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R5, component code 1069 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors of thermoplunger no.3 relay (R5) and of the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R5, component code 1069.
Replace if defective.
Check the continuity and absence of interference resistance on connection 3JAB between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF238/EDC16_V1C_DF238/EDC16_V20_DF238EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20

Page 123 of 365

13B-123
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF239
PRESENT
OR
STOREDTHERMOPLUNGER RELAY CIRCUIT N° 2
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after an engine start or actuator command AC064 Thermoplunger
no. 2 relay.
If faults DF238 “Thermoplunger relay No. 3 circuit” and DF240 “Thermoplunger
relay No. 1 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R11, component code 1068 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors on thermoplunger no. 2 relay (R11) and on the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R11, component code 1068.
Replace if defective.
Check the continuity and absence of interference resistance on connection 3JAA between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF239/EDC16_V1C_DF239/EDC16_V20_DF239

Page 125 of 365

13B-125
MR-372-J84-13B200$324.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of faults
EDC16
Program No.: C1
Vdiag no.: 18, 1C, 20
13B
DF240
PRESENT
OR
STOREDTHERMOPLUNGER N° 1 RELAY CIRCUIT
CO: Open circuit
CC.0: Short circuit to earth
CC.1: Short circuit to + 12 V
1.DEF: Inconsistent signal
NOTESConditions for applying the fault finding procedure to stored faults:
The fault appears after the engine is started or after actuator command AC063
Thermoplunger no. 1 relay.
If faults DF238 “Thermoplunger relay No. 3 circuit” and DF239 “Thermoplunger
relay No. 2 circuit” occur, ignore them and go directly to configuration CF030
“Thermoplunger configuration”.
Special notes:
Use bornier Elé. 1681 for any work on the computer connectors.
See the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
1.DEF
CO
NOTESNone
Check for + 12 V after ignition feed on relay mounting R1, component code 1067 on connection 3FB.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Check the condition of the connectors on thermoplunger no. 1 relay (R1) and on the injection computer.
Repair if necessary.
Check the condition and correct operation of relay R1, component code 1067.
Replace if defective.
Check the continuity and absence of interference resistance of connection 3JA between components 120
and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V18_DF240/EDC16_V1C_DF240/EDC16_V20_DF240

Page 167 of 365

13B-167
MR-372-J84-13B200$504.mif
V13
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5CDIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET004
AC AUTHORISED
STATUS DEFINITIONYES, this status indicates that the air conditioning is active.
NO, this status indicates that the air conditioning is inactive.
NOTESSpecial notes
Only perform these tests if the statuses do not correspond with the system
programming functions.
Engine running, engine coolant temperature > 80 °C
YES
The air conditioning authorisation only changes to YES if:
– the air conditioning request has been made by the driver (air conditioning switch in
AC or AUTO position with minimum ventilation),
– the engine is not under full load,
– the air conditioning system is not faulty.
Conformity check with engine stopped and ignition on
NOStatus ET004 remains NO under the following conditions:
– Vehicle stopped with the ignition on,
– faults present in the air conditioning circuit,
– no air conditioning request made by the driver,
– engine under full load.
If status ET004 remains NO then the air conditioning should be authorised, check:
– that the air conditioning compressor is activated correctly,
– the air conditioning system feed fuses,
– the presence of refrigerant in the air conditioning circuit,
– that the refrigerant fluid pressure value is consistent at idle speed.
If the fault is still present, check the air conditioning computer faults (see62C, Air
conditioning).
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
EDC16_V50_ET004/EDC16_V58_ET004/EDC16-V5C_ET004/EDC16_V18_ET004/EDC16_V1C_ET004/EDC16-V20_ET004

Page 302 of 365

13B-302
MR-372-J84-13B200$756.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of commands
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
AC001
PRE-POSTHEATING UNIT
NOTESThis command is only run if fault DF025 Preheating unit diagnostic line or DF017
Preheating unit control circuit is present or stored and if no other faults are present.
Refer to the Wiring Diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
Switch on the ignition and connect the diagnostic tool.
with the pre-postheating unit connected:
– connect the negative terminal of the voltmeter to connection 3FF of component 257,
– connect the positive terminal of the voltmeter to the + 12 V battery,
– run command AC001.
If the voltmeter does not indicate the battery voltage while the command is running (ten 1-second ON/OFF
cycles):
1- Check the condition of the preheating unit supply fuse F01 (70A).
Replace it if necessary.
2- Check the continuity and the absence of interference resistance of the following connections:
– connection code 3FF,
– connection code 3FY.
Between components 120 and 257.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Repair if necessary.
3- Check the connections on the preheating unit, heater plugs and injection computer.
Repair if necessary.
4- Measure the resistance of the heater plugs. If this resistance is greater than 2 Ω, replace the faulty plug(s).
5- Check the continuity and the absence of interference resistance between the following connections:
– connection code 37AB,
– connection code 37Z,
– connection code 37AC,
– connection code 37AA.
Between components 257, 680, 681, 682 and 683.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
6- Check for + 12 V on connectionBP35 of component257.
if the fault is still present, replace the preheating unit
EDC16_V50_AC001/EDC16_V58_AC001/EDC16_V5C_AC001/EDC16_V18_AC001/EDC16_V1C_AC001/EDC16_V20_AC001

Page 308 of 365

13B-308
MR-372-J84-13B200$756.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of commands
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
AC031
THERMOPLUNGER NO. 3 RELAY
(check that the computer is correctly configured)
NOTESThere must be no present or stored faults.
Perform this fault finding procedure if there is a fault in the command menu, or a
passenger compartment heating/demisting fault.
Refer to the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
vdiag 50, 58, 5C:
If the additional heater no. 3 relay does not operate when running command AC031:
check the engine management computer connections.
Check the connections of thermoplunger no. 3.
Repair if necessary.
Check for + 12 V after ignition supply on connections 3FB and 3JAB of component 1069.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Repair if necessary.
Check the continuity, absence of interference resistance and insulation to earth of connection 3JAB
between components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition supply between connections 3FB and BP9 of component 1069 and connection
3JAC of component 1074.
Measure the resistance of thermoplunger no. 3.
Replace thermoplunger no. 3 if the resistance is greater than 2 Ω.
Replace the water heater interface unit if necessary.
Using a test light, check that the water heater interface unit is properly earthed on connections 3FB and
3JAB between components 120 and 1069.
If the fault is still present, contact the techline.
EDC16_V50_AC031/EDC16_V58_AC031/EDC16_V5C_AC031/EDC16_V18_AC031/EDC16_V1C_AC031/EDC16_V20_AC031

Page 310 of 365

13B-310
MR-372-J84-13B200$756.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of commands
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
AC038
LOW-SPEED FAN ASSEMBLY RELAY
NOTESThere must be no present or stored faults.
Perform this fault finding procedure if a malfunction appears on the command menu
or after an engine cooling system or air conditioning fault.
Refer to the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
If the low-speed fan assembly relay does not operate when command AC038 is run:
Check the low speed fan relay mounting and the connections of the engine management computer.
Repair if necessary.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the low-speed fan assembly relay, fit a 50 Ω < X < 100 Ω resistor on the relay mounting in place of
the coil, and connect a voltmeter as follows:
Positive terminal to the +12 V battery.
Negative terminal to connection 3JN of the low-speed fan assembly relay mounting.
Clear the fault and run command AC038
If the voltmeter indicates the battery voltage (three 2-second ON-OFF cycles), replace the relay.
If the voltmeter does not show the battery voltage (three 2 second ON-OFF cycles), contact the techline.
If the low speed fan assembly relay operates when command AC038, is run, but there is still a fan assembly
activation fault, use the wiring diagram to check the following:
– the conformity of the fan assembly maxi-fuse.
– the conformity of the low-speed fan unit relay,
– the continuity of connection 49L between components 597 and 321.
– the continuity of connection 49B between components 321 and 262.
– the conformity of the fan assembly and the continuity of connection MAS of component 262.
Carry out the necessary repairs.
EDC16_V18_AC038/EDC16_V1C_AC038/EDC16_V20_AC038

Page 311 of 365

13B-311
MR-372-J84-13B200$756.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of commands
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
AC039
HIGH-SPEED FAN ASSEMBLY RELAY
NOTESThere must be no present or stored faults.
Perform this fault finding procedure if a malfunction appears on the command menu
or after an engine cooling system or air conditioning fault.
Refer to the Wiring Diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
If the high-speed fan assembly relay does not operate when command AC039 is run:
Check the high-speed fan assembly relay mounting and the connections of the engine management computer.
Repair if necessary.
If the fault is still present, check that the relay is actuated by the engine management computer as follows:
Disconnect the high-speed fan assembly relay, fit a 50 Ω < X < 100 Ω resistor on its mounting in place of the
coil, and connect a voltmeter as follows:
Positive terminal to the +12 V battery.
Negative terminal to connection 3JP of the high-speed fan assembly relay mounting.
Clear the fault and run command AC039.
If the voltmeter indicates the battery voltage (three 2-second ON-OFF cycles), replace the relay.
If the voltmeter does not show the battery voltage (three 2 second ON-OFF cycles), contact the techline.
If the high-speed fan assembly relay is supplied by command AC039, but there remains a fault with the
triggering the fan assembly. Check using the wiring diagram:
– the conformity of the fan assembly maxi-fuse.
– + battery feed on connection BP71 of the high-speed fan assembly relay mounting,
– the conformity of the high-speed fan assembly relay,
– the continuity of connection 49B between components 597 and 262,
– the conformity of the fan assembly,
– the continuity of connection MAS of component 262.
Carry out the necessary repairs.
EDC16_V18_AC039/EDC16_V1C_AC039/EDC16_V20_AC039

Page 312 of 365

13B-312
MR-372-J84-13B200$756.mif
V13
DIESEL INJECTION
Fault finding – Interpretation of commands
EDC16
Program No: C1
Vdiag No: 18, 1C, 20,
50, 58, 5C
13B
AC063
THERMOPLUNGER NO. 1 RELAY
(check that the computer is correctly configured).
NOTESThere must be no present or stored faults.
Perform this fault finding procedure if there is a fault in the command menu, or a
passenger compartment heating/demisting problem.
Refer to the Wiring diagrams Technical Note for the vehicle to locate the fuses and
relays concerned.
vdiag 50, 58, 5c:
If the additional heater no. 1 relay does not operate when running command AC063:
check the engine management computer connections.
Check the connections of thermoplunger no. 1.
Repair if necessary.
Check for + 12 V after ignition supply on connections BP9 and 3FB of component 1067.
If there is no + 12 V supply, refer to the interpretation of fault DF015 Main relay control circuit.
Repair if necessary.
Check the continuity, absence of interference resistance and insulation on connection 3JA between
components 120 and 597.
If the connection or connections are faulty and there is a repair method (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Using a test light, check the supply by running command AC063 on connection 3JB between components 1067
and 898.
Measure the resistance of thermoplunger no. 1.
Replace thermoplunger no. 1 if the resistance is greater than 2 Ω.
Replace the water heater interface unit if necessary.
Using a test light, check that the water heater interface unit is properly earthed by running command AC063
on connection 3JA between components 120 and 597.
If the fault is still present, contact the techline.
EDC16_V50_AC063/EDC16_V58_AC063/EDC16_V5C_AC063/EDC16_V18_AC063/EDC16_V1C_AC063/EDC16_V20_AC063

Page:   1-10 11-20 next >