AFTER REPAIRRepeat the conformity check from the start.
V12 MR-372-J84-17B000$765.mif
PETROL INJECTION
Fault finding – Interpretation of commands17B
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
AC015
CONTINUED
IF THE PUMP DOES
NOT OPERATEDisconnect the fuel pump.
Check the cleanliness and condition of the connections.
Check for the + 12 V feed on the fuel pump connector with the ignition on (see
Technical Note 8227 Wiring Diagram, MEGANE II, 456).
If there is no + 12V:
– disconnect the battery,
– disconnect the connector marked PPH2 in the Protection and Switching Unit,
– check the cleanliness and condition of the connections,
– using the Universal bornier, check for continuity on the following connection:
Protection and Switching Unit
connector PPH2 track 5Fuel pump connector
Repair if necessary.
Reconnect the Protection and Switching Unit connector and reconnect the battery.
If the + 12 V feed is still not present on the fuel pump relay connector with the ignition
on, there is a fault with the Protection and Switching Unit.
Contact the Techline.
Check that the earth on the fuel pump connector is present with the ignition on
(seeTechnical Note 8227 Wiring Diagram, MEGANE II, 456).
Repair if necessary.
If the fault is still present, replace the fuel pump.