warning RENAULT TWINGO 2009 2.G Sequential Transmission Owner's Manual

Page 45 of 138

21B-45
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF080
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Battery undervoltage
NOTESSpecial notes:
–Fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check that the sequential gearbox supply fuse is correctly positioned and in good condition in the passenger
compartment fuse box.
Measure the battery voltage and check the charging circuit (see Technical Note 6014A, Charging circuit
check).
Repair if necessary.
Ensure that the battery and its connections are in good condition (condition and tightness of the terminals).
Check the engine earths on the vehicle.
Repair if necessary.
Check the connection and condition of the connectors of components 1016 and 119.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check the continuity and insulation of the connections between:
●Connection code BP39,
●Connection code AP4,
between components 119 and 1016.
●The two connections N between component 119 and the chassis earths MC-12A and MC-12B.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF080

Page 47 of 138

21B-47
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF107
PRESENT
OR
STOREDENGINE SPEED MULTIPLEX SIGNAL
1.DEF: Communication disrupted
NOTESPriorities when dealing with a number of faults:
If fault DF062 Multiplex line fault is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the computer fault memory has been cleared, the
ignition has been switched off and on again and the engine has been started.
Special note:
Fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check the connection and condition of the connectors of components 120 and 119.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check the continuity and insulation to earth and to + 12 V on the following connections:
●Connection code 3MT,
●Connection code 3MS,
between components 120 and 119.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
Check the injection system (see 17B, Petrol injection) and deal with any faults.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF107

Page 54 of 138

21B-54
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF145
PRESENT
OR
STOREDINVALID PEDAL POSITION MULTIPLEX SIGNAL
1.DEF : Communication disrupted
NOTESPriorities when dealing with a number of faults:
If fault DF062 Multiplex line fault is present or stored, deal with it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the computer fault memory has been cleared, the
ignition has been switched off and on again and the engine has been started.
Special note:
Fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
Run a multiplex network test (see 88B, Multiplex).
Check the connection and condition of the connectors of components 119, 120 and 921.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check component 921 is correctly positioned on the accelerator pedal.
Run fault finding on the injection system (see 17B, Petrol injection).
If no fault appears, contact Techline.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF145
MR-413-X44-21B000$472.mif

Page 59 of 138

21B-59
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF166
PRESENT
OR
STOREDPRESSURE SENSOR CIRCUIT
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Signal incoherence
NOTESSpecial note:
–Fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
CO.0/ CC.1
NOTESNone
Check the condition and position of the 30 A fuse for the pump in the engine compartment.
Repair if necessary.
Check the connection and condition of the connectors of components 119 and 1059 and the 24 track
intermediate connector located on the hydraulic unit.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check the continuity and insulation to earth and + 12 V on the following connections:
●Connection code 5HN,
●Connection code 5HX,
●Connection code 5AD,
between components 119 and 1059.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the oil pressure sensor on the Sequential gearbox (see MR 411, Sequential
gearbox, solenoid valve unit pressure sensor, Removal refitting).
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF166

Page 62 of 138

21B-62
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF180
PRESENT
OR
STOREDHYDRAULIC PUMP
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared as present if:
–The pump is switched off for 10 seconds.
–If the oil pressure is less than the starting value.
Special note:
–Fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check for + AVC on connection BP36 of component 762.
If there is no + AVC, check fuse F1 30A on component 597.
If the fuse is correct, check the continuity of connection BP36 between components 762 and 597.
If the fuse is not correct, check the insulation to earth of connection BP36 between components 762 and 597.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
wiring: precautions for repair), repair the wiring, otherwise replace it.
Check the connection and condition of the connectors of components 724, 119 and 762.
Also check the connection and condition of the 24-track intermediate connector located on the hydraulic unit.
If the connectors are faulty and if there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the connectors; otherwise, replace the wiring.
Check the continuity and insulation of the following connections:
●Connection code M between component 724 and earth MS-99E,
●Connection code 5AE between components 762 and 724,
●Connection code 5AF between components 119 and 762.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
Case of excessive pump operation:
–Internal or external leak in the circuit. For an external leak, locate the leak and repair if necessary. If there is an
internal leak, replace the hydraulic unit (see MR 411, Sequential gearbox, Electro-hydraulic unit: Removal -
Refitting).
If the fault is still present, replace the accumulator (see MR 411, Sequential gearbox, Pressure accumulator:
Removal - Refitting).
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF180

Page 63 of 138

21B-63
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF181
PRESENT
OR
STOREDGEAR SELECTION IMPOSSIBLE
1.DEF : Impossible to select gear
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after an engine start attempt and an attempt to engage a
gear.
Special note:
–Fault warning light comes on.
–Neutral engaged immediately.
Check that there are no engagement or selection sensor faults.
If faults associated with these components are present, deal with these first.
Check that the selection control lever is correctly clipped to the hydraulic unit (see MR 411, 21B, Sequential
gearbox).
Carry out the necessary repairs.
Check that there is no water in the sequential gearbox oil.
Repair if necessary.
Clear the computer fault memory using command RZ001 "Stored fault(s)".
Carry out the programming procedure for the "Hydraulic unit - gearbox kit (without
clutch) or Clutch or gearbox + Clutch" (see "Replacement of components").
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF181

Page 65 of 138

21B-65
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF187
PRESENT
OR
STOREDPROGRAMMING
1.DEF : Programming not carried out or inconsistent
2.DEF : Values outside the limits
3.DEF : Configuration/Initialisation
NOTESSpecial note:
–Fault warning light comes on.
–Impossible to start the engine.
Program the gears with command VP008 Program selection/engagement ranges.
Check that the solenoid valves are operating correctly using commands AC015 Engagement solenoid valves
and AC016 Selection solenoid valves.
Check the correct positioning of the actuators.
Repair if necessary (see MR 411, 21B, Sequential gearbox, Actuator module: Removal - Refitting).
If the fault is still present, apply the interpretation of faults DF072 Engagement solenoid valve 1 circuit, DF073
Engagement solenoid valve 2 circuit, DF074 Selection solenoid valve 1 circuit and DF075 Selection
solenoid valve 2 circuit.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF187

Page 66 of 138

21B-66
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF188
PRESENT
OR
STOREDSYSTEM OPERATION
NOTESPriorities when dealing with a number of faults:
Apply the interpretation of other faults first.
Special note:
–warning light comes on,
–neutral engaged immediately,
–engine stops immediately.
This fault appears following an electronic and mechanical inconsistency on the sequential system.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF188

Page 67 of 138

21B-67
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF232
DF233
DF234
PRESENT
OR
STOREDCOMPUTER
1.DEF : Internal electronic fault
NOTESSpecial note:
–fault warning light comes on.
Use the Wiring Diagrams Technical Note for New TWINGO.
Check the condition and position of the sequential gearbox fuses in the engine compartment and in the
passenger compartment.
Check the connection and condition of the 52-track connector of component 119.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check for + AVC on connection BP39 and for + after ignition feed on connection AP4 on the 52-track connector
of component 119.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation, continuity and the absence of interference resistance on the following connection:
●Connection code N of earths MC - 12B and MC - 12A.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
Clear the computer fault memory using command RZ001 "Stored fault(s)".
Switch off the ignition.
Switch on the ignition again and carry out a new check using the diagnostic tool.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF232 / BVRJH1_V04_DF233 / BVRJH1_V04_DF234

Page 69 of 138

21B-69
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF252
PRESENT
OR
STOREDPUMP RELAY
1.DEF : Relay jammed
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after a road test.
Special note:
–all gear changes are inhibited,
–fault warning light comes on,
–automatic mode is inhibited.
Use the Wiring Diagrams Technical Note for New TWINGO.
After switching on the ignition, check that the PR018 “Hydraulic pressure” is between 40 bar and 50 bar.If this
is not the case, apply the interpretation for fault DF166 “Pressure sensor circuit”.
If the checks described in DF166 "Pressure sensor circuit" are correct and that PR018 "Hydraulic pressure"
indicates a lower pressure than that measured previously following activation of the pump motor, replace the
pressure sensor (see MR 411, 21B, Sequential gearbox, Solenoid valve unit: Removal - Refitting).
Disconnect the relay and check that there is no continuity between connections BP36 and 5AE of component
762.
Replace the relay if it is not correct.
Check the continuity and insulation of the following connection:
●Connection code 5AE,
Between components 724 and 762.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
Check for the absence of + 12 V on connection 5AE of component 762.
Check the continuity and insulation of the following connection:
●Connection code 5AF,
Between components 119 and 762.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, W iring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF252

Page:   < prev 1-10 11-20 21-30 31-40 next >