sensor SSANGYONG NEW ACTYON SPORTS 2012 Service Manual

Page 768 of 828

01-116810-01
(5) Step 5
In this step, the system checks the temperature sensors used to control the A/C. To enter this
step, turn the temperature dial to the right in the step 4. The ambient temperature appears on the
display first and the interior temperature appears next and the intake air temperature last. The
display changes the temperature value each time the defroster switch is pressed.
1. Turn temperature dial lightly toward right to enter step 5
Press Press Press
Ambient
temperature
displayInterior
temperature
displayIntake air
temperature
display
(6) Step 6
You can increase or decrease by up to 3 degrees from the set temperature. When entering the
step 6 from 5, turn the fan speed dial.
Step 6 starts Decrease by up
to 3 degreesIncrease by up
to 3 degreesTurn fan
speed dial
to enter
step 6 1.
Turn
temperature
control dial to
adjust
temperature 2.

Page 769 of 828

01-12
(7) How to end self-diagnosis
Turn the AUTO switch ON or turn OFF the ignition key.
(8) When A/C system is faulty (Initial auto-diagnosis)
The fault code for the faulty sensor is not displayed. Therefore you should start the self-diagnosis
to check the system.

Page 770 of 828

01-136810-01
3) Trouble Diagnosis
(1) Duct Temperature Sensor
If the fault code for the duct temperature sensor (DTC 3) appears on the display, check the sensor
as follows:
Remove the duct temperature sensor and measure the resistance between the terminals of the
<008a009600950095008c008a009b009600990047004f009a0097008c008a0090008d0090008a0088009b0090009600950061004700880097009700990096009f0055004700590055005900470092007e00470088009b00470059005c0b4500500055004700
70008d0047009b008f008c00470099008c009a0090009a009b>ance value is extremely high or
low, replace the duct temperature sensor.
If the result is not as specified, replace the duct temperature sensor. If the result is as
specified, proceed to the next step.
Turn the ignition switch to ON position and measure the voltage between the connector of the
FATC controller and the duct temperature sensor (specification: approx. 2 V at 25℃).
If the voltage cannot be measured, check the wiring for open circuit. If the result is as
specified, replace the FATC controller. A.
B.
C.
D.
(2) Power Transistor
If the fault code for the power transistor (DTC 6) is displayed, check as follows:
Turn the ignition switch to ON position.
Measure the voltage between the terminals of the blower motor while changing the fan speed
from the lowest level to the highest level.
The specified voltage value in each stage: A.
B.
C.
If the voltage is out of specified value, check the wiring for open circuit. If the wiring is intact,
replace the power transistor. D.
(3) Thermo AMP Sensor (Intake Air Sensor)
If the A/C is not turned on, check as follows:
Remove the thermo AMP and measure the voltage between the terminals no. 1 and 2 of the
connector.
Check if the voltage is approx. 12 V when the output is ON and 0 V when the output is OFF.
If the voltage value is not as specified, replace the thermo AMP. If the value is as specified,
proceed to the next step.
Turn the ignition switch to ON position and turn on the A/C by pressing the A/C button. And
measure the voltage between the terminals A12 and A11 of the FATC controller connector
(specification: approx. 12 V).
If the voltage cannot be measured, check the wiring for open circuit. If the result is not as
specified, replace the thermo AMP. A.
B.
C.
D.
E.

Page 771 of 828

01-14
(4) Sun-load sensor
Remove the sun-load sensor and measure the current between the terminals with the sensor
exposed to direct sunlight.
Measure the current again in the shade. If this value is lower than the measured value in the
sunlight, the sensor is intact.
Turn the ignition switch to the "ON" position.
Measure the voltage between the terminals of the sun sensor at the FATC connector. (approx.
2.5 V under sunlight and approx. 4.8 V under shade)
If the voltage cannot be measured, check the wiring for open circuit. If the result is not as
specified, replace the FATC controller. A.
B.
C.
D.
E.

Page 772 of 828

01-156810-01
1. SYSTEM LAYOUT (EXTERIOR)
Receiver drierA/C compressorLine and port
Ambient temperature sensorA/C condenserElectric fan

Page 773 of 828

01-16
2. SYSTEM LAYOUT (INTERIOR)
Sun-load sensor
A/C controller
A/C Module assembly
Mode door actuatorAir mix door actuator

Page 774 of 828

01-176810-01
Air source mode actuator
Duct temperature sensor
Thermo AMP
PTC
Power transistorBlower motor assemblyA/C filter

Page 776 of 828

01-196810-01
1) Components
4. A/C MODULE
Mode door actuator
PTC heater assembly
Duct temperature sensor
Air mix door actuator
Air source door actuator
A/C antibacterial filter
Blower motor 1.
2.
3.
4.
5.
6.
7.Power transistor
Thermo AMP
Mode door
Heater core
Air mix door
Evaporator
Air source door 8.
9.
10.
11.
12.
13.
14.

Page 777 of 828

01-20
2) Configuration
Air source
door caseA/C filter
Blower unit
(upper) case
Blower motor
assembly
Power
Transistor
A/C cable
assembly
Thermo AMP
Heater unit (right)
case
Air mix door
actuator
Lower duct
Mode door
link assembly Mode door
actuator Heater unit (left) case Mode doorHeater core Duct temperature
sensorEvaporatorBlower unit
(lower) case Air source door
actuator

Page 778 of 828

01-216810-01
Mode door actuatorDuct temperature sensor
Air source door actuator
Power transistor
Blower motor
Thermo AMP Air mix door
actuator
A/C controller unit Interior
temperature
sensor Main wiring
connector
3) Wiring Layout

Page:   < prev 1-10 ... 101-110 111-120 121-130 131-140 141-150 151-160 next >