TOYOTA CAMRY 2000 Service Repair Manual
Page 2291 of 4770
BR0BS±02
± BRAKEFRONT SPEED SENSOR
BR±69
2092 Author: Date:
INSTALLATION
Installation is in the reverse order of removal (See pageBR±68).
HINT:
After installation, check the speed sensor signal (See page DI±493, DI±539).
Page 2292 of 4770
BR0BT±03
W03274
Rear Speed Sensor
N´m (kgf´cm, ft´lbf): Specified torque
5.4 (55, 48 in.´lbf)
7.8 (80, 69 in.´lbf)
5.4 (55, 48 in.´lbf)
BR±70
± BRAKEREAR SPEED SENSOR
2093 Author: Date:
REAR SPEED SENSOR
COMPONENTS
Page 2293 of 4770
BR0BU±03
R00330
W04508
± BRAKEREAR SPEED SENSOR
BR±71
2094 Author: Date:
REMOVAL
1. DISCONNECT SPEED SENSOR CONNECTOR
(a) Remove the seat cushion and side seatback
(See page BO±114 or BO±119).
(b) Disconnect the speed sensor connector, and pull out the
sensor wire harness with the grommet.
2. REMOVE SPEED SENSOR
(a) Remove the 2 clamp bolts holding the sensor wire har-
ness to the body and shock absorber.
Torque: 5.4 N´m (55 kgf´cm, 48 in.´lbf)
(b) Remove the speed sensor from the axle carrier.
Torque: 7.8 N´m (80 kgf´cm, 69 in.´lbf)
Page 2294 of 4770
BR0BV±02
BR±72
± BRAKEREAR SPEED SENSOR
2095 Author: Date:
INSTALLATION
Installation is in the reverse order of removal (See page BR±71).
HINT:
After installation, check the speed sensor signal (See page DI±493, DI±539).
Page 2295 of 4770
CH02U±01
Z11577
Except Maintenance±Free Battery
Z11556
Maintenance±Free Battery
Voltmeter
± CHARGING (5S±FE)CHARGING SYSTEM
CH±1
1748 Author: Date:
CHARGING SYSTEM
ON±VEHICLE INSPECTION
CAUTION:
Check that the battery cables are connected to the
correct terminals.
Disconnect the battery cables when the battery is giv-
en a quick charge.
Do not perform tests with a high voltage insulation re-
sistance tester.
Never disconnect the battery while the engine is run-
ning.
1. CHECK BATTERY ELECTROLYTE LEVEL
Check the electrolyte quantity of each cell.
Maintenance±Free Battery:
If under the lower level, replace the battery (or add distilled wa-
ter if possible). Check the charging system.
Except Maintenance±Free Battery:
If under the lower level, add distilled water.
2. Except Maintenance±Free Battery:
CHECK BATTERY SPECIFIC GRAVITY
Check the specific gravity of each cell.
Standard specific gravity:
1.25 ± 1.29 at 20°C (68°F)
If the specific gravity is less than specification, charge the bat-
tery.
3. Maintenance±Free Battery:
CHECK BATTERY VOLTAGE
(a) After having driven the vehicle and in the case that 20
minutes have not passed after having stopped the en-
gine, turn the ignition switch ON and turn on the electrical
system (headlight, blower motor, rear defogger etc.) for
60 seconds to remove the surface charge.
(b) Turn the ignition switch OFF and turn off the electrical sys-
tems.
(c) Measure the battery voltage between the negative (±)
and positive (+) terminals of the battery.
Standard voltage: 12.5 ± 12.9 V at 20°C (68°F)
If the voltage is less than specification, charge the battery.
Page 2296 of 4770
Z18811
Maintenance±Free Battery
Type A
Type B
Blue White Red
OK Charging
NecessaryInsufficient
Water
GREEN EYE DARK EYECLEAR EYE or
CHARGED DISCHARGED ADD WATERLIGHT YELLOW
Z00015
Z00038
DENSOBorroughs
CH0086
CORRECTWRONG CH±2
± CHARGING (5S±FE)CHARGING SYSTEM
1749 Author: Date:
HINT:
Check the indicator as shown in the illustration.
4. CHECK BATTERY TERMINALS, FUSIBLE LINK AND
FUSES
(a) Check that the battery terminals are not loose or cor-
roded.
If the terminals are corroded, clean the terminals.
(b) Check the fusible link, H±fuses, M±fuse and fuses for
continuity.
5. INSPECT DRIVE BELTS
(a) Visually check the drive belt for excessive wear, frayed
cords etc.
If any defect has been found, replace the drive belt.
HINT:
Cracks on the rib side of a drive belt are considered acceptable.
If the drive belt has chunks missing from the ribs, it should be
replaced.
(b) Using a belt tension gauge, measure the belt tension.
Belt tension gauge:
DENSO BTG±20 (95506±00020)
Borroughs No. BT±33±73F
Drive belt tension:
w/ A/C New belt
Used belt165 ± 25 lbf
110 ± 10 lbf
w/o A/C New belt
Used belt125 ± 25 lbf
95 ± 20 lbf
If the belt tension is not as specified, adjust it.
HINT:
ºNew beltº refers to a belt which has been used less than
5 minutes on a running engine.
ºUsed beltº refers to a belt which has been used on a run-
ning engine for 5 minutes or more.
After installing a belt, check that it fits properly in the
ribbed grooves.
Check with your hand to confirm that the belt has not
slipped out of the groove on the bottom of the pulley.
Page 2297 of 4770
Z03473
BatteryVoltmeter
Generator Ammeter
Disconnect Wire
from Terminal B
B
± CHARGING (5S±FE)CHARGING SYSTEM
CH±3
1750 Author: Date:
After installing a new belt, run the engine for about 5 min-
utes and recheck the belt tension.
6. VISUALLY CHECK GENERATOR WIRING AND
LISTEN FOR ABNORMAL NOISES
(a) Check that the wiring is in good condition.
(b) Check that there is no abnormal noise from the generator
while the engine is running.
7. CHECK CHARGE WARNING LIGHT CIRCUIT
(a) Warm up the engine and then turn it off.
(b) Turn off all accessories.
(c) Turn the ignition switch ºONº. Check that the charge warn-
ing light is lit.
(d) Start the engine. Check that the light goes off.
If the light does not go off as specified, troubleshoot the charge
light circuit.
8. INSPECT CHARGING CIRCUIT WITHOUT LOAD
HINT:
If a battery/generator tester is available, connect the tester to
the charging circuit as per manufacturer's instructions.
(a) If a tester is not available, connect a voltmeter and amme-
ter to the charging circuit as follows:
(1) Disconnect the wire from terminal B of the genera-
tor, and connect it to the negative (±) tester probe
of the ammeter.
(2) Connect the positive (+) tester probe of the amme-
ter to terminal B of the generator.
(3) Connect the positive (+) tester probe of the voltme-
ter to terminal B of the generator.
(4) Ground the negative (±) tester probe of the voltme-
ter.
(b) Check the charging circuit as follows:
With the engine running from idling to 2,000 rpm, check
the reading on the ammeter and voltmeter.
Standard amperage: 10 A or less
Standard voltage: 13.5 ± 15.1 V
If the voltmeter reading is more than standard voltage, replace
the voltage regulator.
Page 2298 of 4770
P14433
Terminal F CH±4
± CHARGING (5S±FE)CHARGING SYSTEM
1751 Author: Date:
If the voltmeter reading is less than standard voltage, check the
voltage regulator and generator as follows:
With terminal F grounded, start the engine and
check the voltmeter reading of terminal B.
If the voltmeter reading is more than standard volt-
age, replace the voltage regulator.
If the voltmeter reading is less than standard volt-
age, check the generator.
9. INSPECT CHARGING CIRCUIT WITH LOAD
(a) With the engine running at 2,000 rpm, turn on the high
beam headlights and place the heater blower switch at
ºHIº.
(b) Check the reading on the ammeter.
Standard amperage: 30 A or more
If the ammeter reading is less than the standard amperage, re-
pair the generator.
HINT:
If the battery is fully charged, the indication will sometimes be
less than standard amperage.
Page 2299 of 4770
CH02V±03
S05342
Pivot BoltAdjusting Lock Bolt
Generator Wire
Generator
Connector
Generator
Drive Belt
Rubber Cap
Wire Clamp
S05076
Pulley
Drive End Flame (Starter) Front Bearing
Bearing CoverRotor
Generator Washer
Rectifier End FlameWire ClipRubber InsulatorRectifier Holder
Voltage RegulatorSeal Plate
Brush Holder
Brush Holder CoverTerminal Insulator
Rear End Cover
Plate Terminal
Non±reusable partBearing Cover
Rear BearingBearing Cover
± CHARGING (5S±FE)GENERATOR
CH±5
1752 Author: Date:
GENERATOR
COMPONENTS
Page 2300 of 4770
CH02W±03
B02375
B02376B02377B02693
w/o A/C
w/ A/C
Pivot BoltAdjusting
Bolt
Adjusting
Lock
Bolt
Pivot Bolt
Adjusting
Lock Bolt
CH±6
± CHARGING (5S±FE)GENERATOR
1753 Author: Date:
REMOVAL
1. DISCONNECT CONNECTOR AND WIRE FROM
GENERATOR
(a) Disconnect the wire clamp from the wire clip on the rectifi-
er end frame.
(b) Disconnect the generator connector.
(c) Remove the rubber cap and nut, and disconnect the gen-
erator wire.
2. REMOVE GENERATOR
(a) Loosen the adjusting lock bolt (w/ A/C), adjusting bolt and
pivot bolt.
Torque:
Pivot bolt: 52 N´m (530 kgf´cm, 38 ft´lbf)
Adjusting lock bolt (w/ A/C) or adjusting bolt (w/o A/C)
18 N´m (185 kgf´cm, 13 ft´lbf)
(b) Remove the drive belt.
(c) Remove the adjusting lock bolt (w/ A/C) or adjusting bolt
(w/o A/C) and pivot bolt.
(d) Remove the generator.