engine TOYOTA T100 1996 Factory Service Manual

Page 2061 of 2062

Downloaded from www.Manualslib.com manuals search engine AC0GV−02
N05735
FRESH Clamp
RECIRC
N05736
Clamp
DEF
FACE
N05734
Clamp
COOL
WARM
− AIR CONDITIONINGHEATER CONTROL ASSEMBLY
AC−91
1996 TOYOTA T100 (RM449U)
INSTALLATION
Installation is in the reverse order of removal (See page
AC−87).
1. AFTER INSTALLATION, INSPECT HEATER CONTROL
LEVER OPERATION
Move the control lever and dials left and right check for stiffness
and binding the full range of the lever.
If there is stiffness and binding, proceed next step.
2. ADJUST HEATER CONTROL CABLES
(a) Set heater control assembly in these conditions:
(1) Air inlet control lever in ”FRESH” position
(2) Mode control lever in ”FACE” position
(3) Temperature control lever in ”Max. WARM” position
(b) Adjust the air inlet control cable.
Set the air inlet damper control damper on ”FRESH” posi-
tion, install the control cable and lock the clamp.
HINT:
Lock the clamp during lightly pushing the outer cable in the
direction shown by arrow.
(c) Adjust mode control cable.
Set the air inlet damper control damper on ”FACE” posi-
tion, install the control cable and lock the clamp.
HINT:
Lock the clamp during lightly pulling the outer cable in the direc-
tion shown by arrow.
(d) Adjust air mix control cable.
Set the air inlet damper control damper on ”WARM” posi-
tion, install the control cable and lock the clamp.
HINT:
Lock the clamp during lightly pulling the outer cable in the direc-
tion shown by arrow.

Page 2062 of 2062

Downloaded from www.Manualslib.com manuals search engine N05737Clamp COOL
WARM
AC−92
− AIR CONDITIONINGHEATER CONTROL ASSEMBLY
1996 TOYOTA T100 (RM449U)
(e) Adjust water valve control cable.
Set the air inlet damper control damper on ”WARM” posi-
tion, install the control cable and lock the clamp.
HINT:
Lock the clamp during lightly pulling the outer cable in the direc-
tion shown by arrow.