Air Conditioning (A/C) System (12.03)
Climate Control (12.00)
May 2007 Workshop Manual 12-3-3
The A/C unit houses the evaporator, heater matrix and air
flow flaps.
The unit also incorporates two servo motor operated air
distribution flaps.
1. Regulates airflow to the cabin vents.
2. Regulates airflow to the defrost / demist air ducting.
When the cabin air flap is open, air is ducted to the cabin via
face and foot level air vents.
Condensate (water) which forms on the evaporator fins is
drained out of the unit case through a drain hose, located at
underneath / rear of the evaporator.
Refrigerant System
Warning
Do not perform a pressure test or leak test for R-134a service equipment and or vehicle A/C using
compressed air. Some mixtures of air and R-134a have
been shown to be combustible at elevated pressures.
These mixtures, if ignited, ma y cause injury or property
damage. Additional health and safety information may
be obtained from refrigerant manufacturers.
Warning
Do not allow refrigerant to leak near a fire or any kind of heat. A poisonous gas may be generated if
refrigerant gas contacts fire or heat such as from
cigarettes and heaters. When carrying out any
operation that can cause refr igerant leakage, extinguish
or remove the above mentioned heat sources and
maintain adequate ventilation.
Warning
Handling liquid refrigerant is dangerous. A drop of
refrigerant on the skin can result in localized frostbite. When handling refrigerant, wear gloves and safety
goggles. If refrigerant sp lashes into the eyes,
immediately wash them with clean water and consult a doctor.
Warning
Avoid breathing A/C refrigerant or lubricant vapor.
Exposure may irritate eyes, nose and throat. Also, due
to environmental concerns , Aston Martin recommend
the use of a recovery/recycling/recharging unit when
draining R-134a from the A/C system. If accidental A/C
system discharge occurs, vent ilate the work area before
resuming service.
Page 637 of 947

Air Conditioning (A/C) System (12.03)
Climate Control (12.00)
12-3-4 Workshop Manual May 2007
Storing Refrigerant
Handling Insufficient Refrigerant Level
Handling Compressor Oil
Refrigeration Cycle
Operation
1. The Compressor (1) dr aws low pressure, low
temperature, refrigerant vapour from the evaporator (5)
and compresses it, raising th e refrigerant pressure and
temperature.
2. This high pressure, hot, refrigerant vapour enters the condenser (2), where it is cooled by the flow of ambient
air and changes state into a cooler, high pressure liquid.
3. From the condenser, the liqu id passes into the receiver
drier (3) which has three functions:
• Removes moisture from the refrigerant using a desiccant
• Filters the refrigerant to remove system contaminants
• Stores the refrigerant to cope with varying system refrigerant demands
4. The filtered liquid refrigerant, still at high pressure, then enters the expansion valve (4). Here it passes through a
controlled orifice and emerges as an atomised liquid
spray. This has the effect of reducing the refrigerant
pressure and temperature. The cold refrigerant spray
now flows into the evaporator (5).
5. As refrigerant passes through the evaporator core, it cools the incoming airflow. Heat is absorbed by the
refrigerant, during this process and it once again changes
state, from an atomised cool liquid into a vapour. The
refrigerant vapour then returns to the compressor for the
cycle to be repeated.
An automatic safety valve is incorporated in the compressor,
which will open if the system pressure rises above 41 bar.
The valve will reseat when the pressure drops below 27,6
bar. When the safety valve is open, the compressor will 'free
Warning
The refrigerant container is highly pressurized. If it is subjected to high heat, it could explode, scattering metal fragments and liquid refrigerant that can
seriously injure personnel. Store refrigerant at
temperatures below 40
oC (104 oF).
Caution
If an insufficient refrigerant level is detected while
troubleshooting, do not char ge (add) the refrigerant.
Because an accurate amount of refrigerant cannot be
determined from the pressure indicated on the
recovery / recycling / rechar ging unit, never charge the
refrigerant.
Caution
If there is too much or to o little refrigerant from the
refilling, there may be secondary problems such as
damage to the refrigerant cycl e parts, or a decrease of
cooling performance. Therefore, if it is determined that the refrigerant level is insufficient, completely remove refrigerant from the refriger ant cycle and refill with
refrigerant to the specified amount.
Caution
Use only ND8 compressor oil for this vehicle. Using a PAG oil other than DENSO OIL8 compressor oil will damage the A/C compressor.
Caution
Do not spill the ND8 compressor oil on the vehicle. A drop of compressor oil on the vehicle surface can
damage the paint work. If oil gets on the vehicle, wipe it off immediately.
Caution
ND8 compressor oil has a high moisture absorption
efficiency. If moisture mixe s with the compressor oil,
the refrigerant system could be damaged. Ensure caps
are installed immediately afte r using the compressor oil
or removing refrigerant system parts to prevent moisture absorption.