power steering AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual A4 1998 B5 / 1.G AUDI AUDI https://www.carmanualsonline.info/img/6/934/w960_934-0.png AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual

Page 8 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-8
 
  
Ribbed belt drive for power steering pump, 
Generator and viscous fan
 
Note:  
Mark the direction of rotation with chalk or felt pen 
before removing the ribbed belt. If the belt rotates in

Page 10 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-10
 
  
8 - 
23 Nm 
9 - 
Tensioner for ribbed belt 
Turn with open end spanner to loosen 
ribbed belt   Page 13
-18
 . 
Hold in position by inserting a suitable pin 
or Allen key in holes. 
10 - 
4

Page 12 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-12
 
  
 Repair Manual, Suspension, Wheels, Steering, 
Repair Group 48
    15 - 
45 Nm 
16 - 
Support 
For intake manifold
17 - 
20 Nm 
18 - 
52 Nm Apply D 000 600 when installingBolts have differe

Page 13 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-13
 
  
22 - 
Pulley 
For power steering pumpInstallation position: Open side faces to 
front of vehicle 
23 - 
23 Nm 
24 - 
Ribbed bolt - 28 Nm 
25 - 
Viscous coupling Removing and installing   Pa

Page 28 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-28
      
Bracket for Generator, power steering 
pump and viscous fan, removing and 
installing
 
     
Removing  
     
-  Observe or obtain radio anti-theft code on 
vehicles with coded radio.

Page 31 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-31
      
-  Remove tensioner for ribbed belt from 
bracket. 
     
-  Remove pulley from power steering pump.
     
-  Unbolt power steering pump, move clear to one 
side and tie in place. Do not

Page 34 of 47

AUDI A4 1998 B5 / 1.G AWM Engine Assembly Workshop Manual 13-34
      
-  Actuate all window switches again for at least 
one second in the "close" direction to activate 
the automatic open/close function. 
     
-  Set clock to correct time.
     
Tightenin