fuse AUDI A6 1999 C5 / 2.G ATQ Engine Motronic Injection System Servicing Workshop Manual
[x] Cancel search | Manufacturer: AUDI, Model Year: 1999, Model line: A6, Model: AUDI A6 1999 C5 / 2.GPages: 78, PDF Size: 1 MB
Page 45 of 78

24-38
Checking voltage supply
Test requirements:
Fuel Pump (FP) OK, checking Page 24
-
49
.
Fuse for fuel injectors OK
Electrical Wiring Diagrams, Troubleshooting &
Component Locations binder
- Disconnect harness connector at the fuel
injector to be tested.
If LED does not light up: - Connect VAG1527B voltage tester as follows:Harness connector
Terminal
Measure to
1 Engine Ground (GND)
- Switch ignition on.
LED must light up.
Pa
ge 45 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1
Page 46 of 78

Electrical Wiring Diagrams, Troubleshooting & Component Locations
binder - Check wire connection between terminal 1 and fuse for injector valves
for open circuit:
Pa
ge 46 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1
Page 64 of 78

24-54
If specified value is obtained:
If no malfunctions are detected:
Check voltage supply for Fuel Pump (FP) and components - Check the following wire connection for open circuit and short circuit to
Ground (GND) and B+:
Central electric
in driver-side footwell, left, position 4
Terminal
VAG1598/31 test box
Socket
16 65
- Repair open circuit or short circuit if necessary.
- Replace Fuel Pump (FP) relay -J17-.
- Re-connect Engine Control Module (ECM).
- Remove fuses S228, S229, and S234 (positions 28, 29, and S234)
from fuse holder.
- Initiate output Diagnostic Test Mode Page 01
-56
and activate
Evaporative Emission (EVAP) canister purge regulator valve -N80-.
Pa
ge 64 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1
Page 65 of 78

24-55
- Connect multimeter for voltage measurement to
Ground (GND) and to one terminal of the
following fuses in the fuse holder.
Fuse
Specified value at one of the
terminals
S228 approx. battery voltage
S229 approx. battery voltage
S234 approx. battery voltage
If specified values are not obtained:
- Repeat test at another terminal of fuse socket.
If specified values are not obtained again:
- Check wire connections.
Electrical Wiring Diagrams, Troubleshooting &
Component Locations binder If no malfunctions are detected:
- Replace Fuel Pump (FP) relay -J17-.
- Re-insert the fuses.
Pa
ge 65 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1
Page 67 of 78

24-57
Test requirements:
Coolant Temperature at least 80 C.
Electrical consumers switched off (radiator
fan must NOT run during test).
A/C switched off.
Fuse for Mass Air Flow (MAF) sensor OK
Electrical Wiring Diagrams, Troubleshooting &
Component Locations binder
Checking function
- Connect VAS5051 tester or VAG1551 scan tool
and select the control module for engine
electronics using "address word" 01 Page 01
-
9 .
Engine must run at idle for this.Rapid data transfer
HELP
Select function XX
When indicated on display:
-
Press buttons -0- and -4- to select "Initiate basic setting" and press -Q-
Pa
ge 67 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1
Page 73 of 78

24-61
Voltage supply for Mass Air Flow (MAF)
sensor, checking
- Disconnect connector from Mass Air Flow (MAF)
sensor.
Note:
Voltage is supplied to Mass Air Flow (MAF) sensor from Fuel Pump (FP)
relay.
If specified value is not obtained:
Electrical Wiring Diagrams, Troubleshooting & Component Locations
binder - Connect multimeter for voltage measurement as follows.Harness connector
Terminal
Measure to
3 Engine Ground (GND)
- Operate starter briefly.
Specification: approx. battery voltage
- Check wire connection from terminal 3 of connector to Fuel Pump (FP)
relay via fuse for open circuit and short circuit to Ground (GND):
Pa
ge 73 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1