load capacity Citroen C5 2000 (DC/DE) / 1.G User Guide
[x] Cancel search | Manufacturer: CITROEN, Model Year: 2000, Model line: C5, Model: Citroen C5 2000 (DC/DE) / 1.GPages: 259, PDF Size: 2.29 MB
Page 143 of 259
Downloaded from www.Manualslib.com manuals search engine 140
INJECTION
FEATURES OF MULTIPOINT INJECTION SYSTEM
Fuel circuit
Air inlet circuit
(diagr.) Component Supplier Reference Observations
30
4
19
21
20
7
31
6
5
9Recommended fuel
Petrol injector
Canister purge electrovalve
Fuel tank
Canister reservoir
Fuel pump and gauge assembly
with integral fuel filter
Air temperature sensor
Air inlet pressure sensor
Idle regulation stepper motor
Butterfly housing
PotentiometerSAGEM
BOSCH
SAGEM (1)
SOLVAY
MGI
MARWAL
MAGNETI
MARELLI
BOSCH
MGI
MAGNETI
MARELLI (1)
MGI
MAGNETI
MARELLI280520274
IAT S04
0261230034
B13 (1)Unleaded 95 RON or 98 RON
2 way black connector. Resistance : 12,2 ohms
2 way brown connector. Installation : between the engine
fusebox and the brake amplifier
Capacity = 66 Litres
Installation : in the rear LH wheelarch
6 way black connector. Pressure : 3,5 Bars.
2 way grey connector, fixed on the butterfly housing
3 way grey connector integral with the inlet manifold.
4 way black connector, fixed on the butterfly housing
The butterfly housing comprises the inlet air temperature
sensor, the butterfly potentiometer, the electric motor.
3 way black connector, installed on the butterfly housing.
(1) = RFNengine
Page 147 of 259
Downloaded from www.Manualslib.com manuals search engine 144
INJECTION
FEATURES OF MULTIPOINT INJECTION SYSTEM
Fuel circuit
(diagr.) Component Supplier Reference Observations
8Petrol pressure regulator
22Petrol injector
27Petrol high pressure sensor
11Canister purge electrovalve
16Fuel tank
14Canister reservoir
15Fuel pump and gauge assembly
17Air temperature sensor
13Butterfly housing
13Butterfly housing motor
13Butterfly potentiometer
18Inlet air pressure sensor2 way brown connector, located on the petrol injection
common rail.
2 way orange connector, resistance : 1,88 ohms.
3 way black connector, located on the petrol injection
common rail.
2 way brown connector.
Capacity = 66 Litres.
Installed inside the rear LH wheelarch.
6 way black connector, pressure : 5 bars, integrated
fuel filter.
2 way grey connector, resistance : 2,05 kohms
The butterfly housing comprises :
Inlet air temperature sensor, butterfly potentiometer, electric
motor.
6 way black connector.
3 way grey connector, fixed under the air inlet manifold. SIEMENS5403
5048
5402
280520274
IAT S04
98023100 BOSCH
SOLVAY
MGI
MARWAL
MAGNELI
MARELLI
MGI
MAGNELI
MARELLI
BOSCHAir inlet circuit
Page 152 of 259
Downloaded from www.Manualslib.com manuals search engine 149
INJECTION
FEATURES OF BOSCH ME 7.4.6 MULTIPOINT INJECTION SYSTEM
Fuel circuit
(diagr.) Component Supplier Reference Observations
Recommended fuel
33Fuel tank
9Pump, fuel filter and pressure
regulator assembly
34Canister reservoir
15Canister purge electrovalve
18Petrol injector
31Pulse damper
25Integral pressure sensor
14Motorised butterfly housing
26Accelerator pedal position
sensorSuper unleaded 95 RON or 98 RON
Capacity = 66 Litres, polyethylene.
Electric pump immersed in the tank, voltage = 12 V,
Bars, Flow = 115 at 120 l/h, regulation pressure = 3,5 Bars.
Located under front LH wing.
Electrovalve normally closed. 2 way brown connector, located
under the front LH wing, resistance = 24 ohms.
Group of injectors 1.2.3: 2 way brown connector.
Group of injectors 4.5.6 : 2 way yellow connector, injector
with 4 jets. Resistance = 16 ohms.
Installed on the timing cover, equipped with a SCHRAEDER
valve.
2 way black connector, incorporated in the air inlet manifold.
Double potentiometer, supply = 5 Volts, fixed on the engine
compartment. MARWAL
PURFLUX
BOSCH
BOSCHPPGF 30
0 280142 317
EV 8 E
0280155613
0280161500
DS-S2
0261260140
Air circuit
Page 158 of 259
Downloaded from www.Manualslib.com manuals search engine 155
INJECTION
FEATURES OF BOSCH HDi DIRECT INJECTION SYSTEM
Component (diagr.) Supplier Reference Observations
Recommended fuelDiesel
Fuel temperature sensor5ELTHOn the injection rail
Fuel high pressure sensor6BOSCHD281022093 On the injection rail
Fuel tank15Capacity = 68 litres.
Composition : Polyethylene.
Fuel pump16VDOElectric pump immersed in the tank. Voltage 12V.
Pressure : 7 Bars.
Fuel filter
17BOSCH0450907Fixing : on the engine.
Low pressure regulator Adjustment : 2,5 bars.
Fuel cooler18LON Fixed under the bodyshell.
Fuel heater19Integral with the coolant outlet housing.
Fuel high pressure pump20BOSCHCPThe fuel high pressure pump is driven by
the timing belt
Fuel high pressure injection
common rail21BOSCH86313 On the engine (18 cc).
Fuel circuit
Page 163 of 259
Downloaded from www.Manualslib.com manuals search engine 160
INJECTION
FEATURES OF BOSCH HDi DIRECT INJECTION SYSTEM
Fuel circuit
Component (diagr.) Supplier Reference Observations
Recommended fuel Diesel
Fuel tank16Capacity = 65 Litres – Polyethylene.
Fuel tank17VDOElectric pump immersed in the tank.
Voltage: 12 volts – Pressure : 2 Bars
Fuel filter
18BOSCH0450907Fixing : on the engine.
Low pressure regulator Adjustment : 2,5 Bars
Fuel cooler19NOBEL
PLASTIQUEFixed under the bodyshell.
Fuel high pressure pump21BOSCHCP1The high pressure pump is driven by the timing
belt.
Diesel injectors23BOSCH9625542580
Fuel high pressure regulator31BOSCHFixed on the fuel high pressure pump.
Fuel high pressure pump 3rd piston
deactivator32BOSCHFixed on the fuel high pressure pump.
Fuel high pressure injection
common rail22BOSCH86313 On the engine (18 cc)
Fuel high pressure sensor7BOSCHD281022093 On the injection rail
Fuel temperature sensor6ELTHOn the injection rail
Fuel heater20Integral with the coolant outlet housing.
Page 168 of 259
Downloaded from www.Manualslib.com manuals search engine 165
INJECTION
Electrical circuit (continued)
FEATURES OF BOSCH HDi DIRECT INJECTION SYSTEM
Component (diagr.) Supplier Reference Observations
Built-in systems interface (BSI)33
Cruise control safety switch35
Switching module
(under the steering wheel)37
Fuel cap presence sensor49
FEATURES OF BOSCH HDi DIRECT INJECTION SYSTEM
Fuel circuit
Component (diagr.) Supplier Reference Observations
Recommended fuelDiesel
Fuel temperature sensor65MAGNETI
MARELLIOn the injection rail
Fuel high pressure sensor64BOSCHOn the injection rail
Fuel tank42Capacity = 68 Litres – Polyethylene
Fuel pump44VDOElectric pump immersed in the tank
Voltage : 12 V – Pressure : 2 Bars
Fuel filter
59BOSCHFixing on the engine
Low pressure regulator Adjustment : 2,5 Bars
Fuel cooler58NOBEL
PLASTIQUEFixed under the boyshell
Page 238 of 259
Downloaded from www.Manualslib.com manuals search engine 235
HYDRAULIC
SYSTEM
B4BP01BC
HYDRAULIC SPECIFICATIONS
Reservoir
Reference Function Component
"d"InductionBuilt-in Hydro-electronic. Interface (BHI).
Power steering pump
"e"Built-in Hydro-electronic. Interface (BHI).
"f"Return Power steering pump
"c"Suspension cylinders
Synthetic fluid TOTAL FLUIDE LDS.
Capacity of the circuit 4.3 litres.
Page 247 of 259
Downloaded from www.Manualslib.com manuals search engine 244
AIR
CONDITIONING
6FZ
RFN
RLZ SD 7 V16135SP 10
CITROËN
XFX11/2000 :650
6
C5
4HX+0 -50 gr
RHY DELPHI V5
265 ± 15PLANETELF
RHZ (1) 488
AIR CONDITIONING R 134 a (HFC)
Vehicle Engines DateRefrigerant
refillCompressor
Variable
capacityNumber
of valvesOil
quantity ccOil
reference
(1) HARRISON Division.
Page 256 of 259
Downloaded from www.Manualslib.com manuals search engine C5HP15QP
AIR CONDITIONING SYSTEM R 134.a
Engines : 6FZ - RFN - RLZ
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Capacity.
(a) Condenser bracket
Tighten to 0,8 m.daN
(b)Pressure control valve
Tighten to 0,8 m.daN
(c)Compressor bracket
Tighten to 2,5 ± 0,1 m.daN
(d) Condenser dryer reservoir
Tighten to1,4 ± 0,2 m.daN.
AIR
CONDITIONING
253
Page 257 of 259
Downloaded from www.Manualslib.com manuals search engine AIR
CONDITIONING
254
C5HP15RP
AIR CONDITIONING SYSTEM R 134.a
Engine : XFX
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Capacity.
(a) Condenser bracket
Tighten to 0,8 m.daN
(b)Pressure control valve
Tighten to 0,8 m.daN
(c)Compressor bracket
Tighten to 2,5 ± 0,1 m.daN
(d) Condenser dryer reservoir
Tighten to1,4 ± 0,2 m.daN.