engine DACIA SOLENZA 2004 Repair Manual

DACIA SOLENZA 2004 Repair Manual SOLENZA 2004 DACIA DACIA https://www.carmanualsonline.info/img/8/56875/w960_56875-0.png DACIA SOLENZA 2004 Repair Manual

Page 373 of 891

DACIA SOLENZA 2004  Repair Manual GENERAL
Lower  structure composing elements........... 40-1
Upper structure composing elements........... 40-2
Ca rriage bo dy  remo vable  elem ents.............. 40-3
Op enings  clea rance .........

Page 415 of 891

DACIA SOLENZA 2004  Repair Manual 46
BODY PROTECTION
46 -1
 Engine shield
DISMOUNTIN G
Dismount four M 6x1  – 20 Embase scre ws attached  in four  (3) M6x1 safety  nuts on the
power train support. Release  the engine shield  (1).
RE

Page 446 of 891

DACIA SOLENZA 2004  Repair Manual REPAIR MANUAL
  DACIA
RM 525-3 SEALING, ELECTRICITY
ENGINE: E7J
G EARBOX: JH3
TA P V:  B 41A, B41B, B41C
Ref: 6001999067     MARCH  2004 English version
The reparation methods prescribed by the manufa

Page 448 of 891

DACIA SOLENZA 2004  Repair Manual INSIDE AND REAR LIGHTING
Inside and rear lighting .................................... 81-1
Ceili ng lamp ...................................................... 81-4
Bulbs ... ........................

Page 466 of 891

DACIA SOLENZA 2004  Repair Manual 61
HEATING
61 - 4
Climate control unit
DISMOUNTING
Disconnect the battery.
Dismount :
- climate control box protector;
- climate  control box gasket
- gas purge vessel;
- engine air filter.
Detach fro

Page 467 of 891

DACIA SOLENZA 2004  Repair Manual 61
HEATING
61 - 5
123
Ve
ntilation-climate control air distributor (RACV)
DISMOUNTIN G
Disconnect the battery.
Dismount :
- dashboard (see chapter 57  “dash-
board”);
- central console;
- electric

Page 482 of 891

DACIA SOLENZA 2004  Repair Manual 62
AIR CONDITIONING
62- 8
Cold air blowing device (DSAF)
TIGHTENING MOMENTS     (daNm)
Attachments  screws of  the expansion vale on  the evaporator 0,6
Pipes attachment  nut on evaporator 0,57
T ight

Page 487 of 891

DACIA SOLENZA 2004  Repair Manual 62
AIR CONDITIONING
62 - 13
Condenser
SPECIAL TOOLS
MOT 453Hoses clamp
MOT 1202-01 Elastic clips pliers
The condenser  is  placed on  the c ooling
radiator,  ensuring the exhaust of  the refrigerant
h

Page 488 of 891

DACIA SOLENZA 2004  Repair Manual 62
AIR CONDITIONING
62- 14
Pressure controller
LOCATION
Pressure controller  (1) is located on  the  high-
pressure pipe, near the dryer reservoir.
FUNCTION
The pre ssure control ler  is  perm anently

Page 522 of 891

DACIA SOLENZA 2004  Repair Manual 80
BATTERY - FRONT HEADLIGHTS
80 - 1
CHECKING
It is recommended to check the following: -cr acks or breaches of the ba ttery box (c ase)
- battery upper part cleanness
- plugs condition
It is required