IGNITION AND INJECTION
17
17 - 52
RECOMMENDATIONS
Diagnostic – Failures interpretation
DF 109
DF 110
P RESENT
OR
ME MO RIZEDPOLLUTED COMBUSTION MISFIRE
DESTRUCTIVE COMBUSTION MISFIRE
St ate ET014 : Recognition of the cylinder 1 must be active, in order to
i dentify each cylinder.
ET093 : combustion misfire on cylinder 1
ET094 : combustion misfire on cylinder 2
ET095 : combustion misfire on cylinder 3
ET096 : combustion misfire on cylinder 4
These w ill provide information regarding failure cause and location.
In this situation, the problem is probably due to an element that can act
only on one cylinder:
- Problem at injector
A cylinder is declared - Problem at spark plug
damaged : ET093 or ET094 - Problem at high voltage cable.
or ET095 or ET096. Before replacement, try the spark plug or cable changing to anothe r
cylinder.
Cy linders 1 and 4 or In this cylinders 2 and 3 declared situation, the proble m is probably
damaged : ET093 and ET 0 96 due to an eleme nt that can act only this pair of cylinders:
or ET094 and ET095. - Problem at ignition coil, at the high voltage part. - Problem at ignition coil, at the control part
In this situation, the problem is probably due to an element tha t can
F our cylinders declared act only on all cylinders:
damaged : ET093 and -Problem at fuel filter
ET094 or ET095 and ET096. -Problem at fuel pump
-Problem on in use fuel type
-Problem of in use spark plugs
In case by using this method the problem is not solved, cons ult the fail ures diagnostic DF109 / DF
1 10 CONTINUA TION
Ensure that all failures are solved. Erase all memorized failures.
There is no need to erase the “adaptive values” memoriz ed by the injection computer.
In order to check the correct reparation of the system, the following conditions must be
AF TER accomplished:
REPARATION - No more electrical failures;
- All “adaptive values” to be memorized by the injection computer;
- Warm engine (minimum 75°C);
- Run at idling, all consumers being in use for 20 minutes (1 minute DF110);
- If the failure is again occurring, repeat the dia gnostic.
vnx.su
Page 147 of 891

IGNITION AND INJECTION
17
17 - 53
Diagnostic – Failures interpretation
DF 109
DF 110
CONTINU AT I O N
ET093 : combustion misfire on cylinder 1
ET094 : combustion misfire on cylinder 2
RE COMMENDATIONSET0 95 : combustion misfire on cylinder 3
ET096 : combustion misfire on cylinder 4
These w ill provide information regarding failure cause and location.
C heck the ignition system ( refer to chapter “Help” ).
Fix it if necessary.
C heck the engine compression.
Fix it if necessary.
C heck the flywheel condition , in order to get a correct information of the engine RPM.
Fix it if necessary.
If no failure has been found, there is a problem on the fuel supply cir cuit.
In this situation the following must be checked:
- Fuel filter
-F uel pressure and flow
-F uel pump condition
-F uel tank cleaning condition]
-I njector s conditions
Mend the fuel supply circuit.
Ensure that all failures are solved. Erase the memorized failures.
There is no need to erase the “adaptive values” memorized by the injection
computer. In order to check the correct reparation of the system, the following
conditions must be accomplished:
AF TER - No more electrical failures.
REPARATION - All “adaptive values” to be memor ized by the injection computer.
- Warm engine (minimum 75°C)
- Run at idling, all consumers being in use for 20 minutes (1 minute
DF110).
vnx.su
Page 150 of 891

IGNITION AND INJECTION
17
17 - 56
Diagnostic – Failures interpretation
DF 261 FUEL PUMP RELAY CIRCUIT
P RESENT 1. DEF Supply failure + after relay
OR 2. DEF Open circuit or short-circuit
ME MO RIZED
If failure “DF345 : Supply 5 volts potentiometers and sensor s” is
present or memori zed, it must be treated as most important .
Conditions for diagnostic appl ication at memorized failure:
Se t the contact on, then enter in dia logue with the computer
Or activation of the actua tor control “ AC 010 : Fuel pump relay”.
RECOMMEND ATIONS REMARK : This failure is most important. So it must be treated before
t he next ones.
* If the failure is memorized with OBD indicator on, check in the context
part, if state “ET241 : Fuel pump control cir cuit” corresponding to the
OBD indicator lighting request is affir mative. In this case , proceed as
per bellow mentioned method
1. DEF RECOM MENDAT IONS It is a failure on the power circuit of the fuel
pump relay.
C heck the electric continuity f the idleness contact.
Me nd if necessary.
C heck the connection and con dition of the fuel pump relay connector .
R eplace the connector if necessary.
C heck the presence of the +12 volts supply at pole 3 of the fuel pump relay
Me nd if necessary.
C heck with the contact set on a nd acting the actuator c ontrol “AC010 : Fuel pump relay”, the
prese nce of +12 V supply at pole 5 of the fuel pump relay.
R eplace the relay if necessa ry
C heck the insu lation and cont inuity of the connections between:
Pole 5 fuel pump relay > pi n C ignition coil
Pole 5 fuel pump relay > fuel pump
Me nd if necessary.
If the problem is persisting after these checking, treat the other failures then perform the
conformity checking.
Perform the operations from ” recommendations” for reparation confirma tion.
AF TER Fix any other possible failures
REPARATION Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
vnx.su
Page 151 of 891

IGNITION AND INJECTION
17
17 - 57
DF 261
CONTINU AT I O N
2. DEF RECOM MENDAT IONS It is a failure on the power circuit of the fuel
pump relay.
C heck the connection and condition of the fuel pump relay connector .
R eplace the connector if necessary.
Check, with the contact set non, the pr e sence of the +12 volts supply at pole 1 of the fuel pump
relay.
M end if necessary.
C heck the fuel pump rela y coil.
R eplace the fuel pump rela y if necessary.
Check the insu lation and continuity of the line:
Pin 68 injection computer > pole 2 fuel pump relay
M end if necessary.
If the problem is persisting after these checking, treat the other failures then perform the conformity
checking.
P erform the operations from ” recommendations” for reparation confirma tion.
AF TER Fix any other possible failures
REPARATION Erase the failures memoriz ed by the injection computer.
Perform a conformity checking by means of the CLIP tester.
Diagnostic – Failures interpretation
vnx.su
Page 155 of 891

IGNITION AND INJECTION
17
17 - 61
RECOMMEND AT IONS The values show n on this conformity checking are only as indication.
Performing conditions : St opped engine, contact set on.
Sequence Function Parameter / Controlled state or acti on Visualization Diagnostic
and Observations
1V oltage ET001 : after contact computer In case of a
PR004 : computer supplying voltage ACTIV Eproblem
c onsult
th e PR004
dia gnostic
LC012 : O2 sensor option reading With one wire or three wires
LC017 : Engine fan driving with running engine With (if the option
is existing)
LC019 : upstream oxygen sensor With
LC020 : downstream oxygen sensor With (if the option is existing)
2 Comp uter LC036 : low flow fuel pump configuration With (if the option Nothing to
is existing) be noticed
LC042 : AC cold loop at injection With (if the option is existing)
LC048 : climate control configuration reading With (if the option is existing)
LC054 : Gearbox type Mechanical gearbox
LC096 : Compres sor with fix cy linder capaci ty With (if the option
is existing)
Diagnostic – Conformity checking
vnx.su
Page 157 of 891

IGNITION AND INJECTION
17
17 - 63
Diagnostic – Conformity checking
RECOMMEND AT IONS The values show n on this conformity checking are only as indication.
Performing conditions : St opped engine, contact set on.
Sequence Function Parameter / Controlled state or acti on Visualization Diagnostic
and Observations
8F uel pump AC010 : Fuel pump relay The fuel pump In case of a
must be heard problem
running consult the AC010
dia gnostic
AC271 : low speed engine blower relay The engine
9 Engine blower must
blower be heard In case of a
running with problem low speed consult the
AC272 : high speed engine blower relay The engine ET035
(if equipped) blower must(ET036)
be heard running dia gnostic with high speed
10 Idling AC014 : idling regulator Place your hand In case of a
regulator under it to feel problem
it running. c onsult
the ET 039
dia gnostic
11 Canister AC016 : canister purging valve Canister purging In case of a
purging valve valve in operation problem
consult the ET032
dia gnostic
12 Climate AC003 : Climate control compressor Compressor In case of a
control must couple problem
consult theET070
dia gnostic
13 Indicators AC212 : water temperature indicator Indicator In case of a
must be on problem
AC213 : OBD indicator Indicator consult the
must be on AC212
AC 005 : rate changing indicator (if equippe d) Indicator / DF120
must be on (ET092)
diagnostic /
diagnostics
vnx.su
Page 158 of 891

IGNITION AND INJECTION
17
17 - 64
Diagnostic – Conformity checking
Sequence Function Parameter/Controlled s tate or action Visualization Diagnostic
and Observations
1B attery ET001 : +after contact computer ACTIV EIn case of a problem
volta ge PR004 : computer supply voltage 13 < X < 14.5V consult the PR004 If PR004 = X< 12.8 V dia gnostic
Then PR006 : engine regi me750 < X < 910 rpm
2F uel pump ET020 : Fuel pump relay control ACTIV EIn case of a problem
control consult the AC010
dia gnostic
3A ctua tor ET025 “ Actuators relay control ACTIV EIn case of a problem
control consult the DF009
dia gnostic
4R PM signal ET060 : RPM signal to running eng ineACTIVEIn case of a problem
consult the DF017 dia gnostic
5 No1 cylinder ET014 : No.1 cylinder recognition PERFORMED Nothing to be
recognition (only if ET011 Active) notic e d
6 Oxygen ET030 : Upstream O2 sensor heating ACTIV ECheck operation
se nsor c onditions
he a ting ET031 : Downstream O2 sensor ACTIV E
heating (if present)
7V alve ET003 : valve pos ition at released YES In case of a problem
potentiometer pedal consult the DF017
dia gnostic
8I dling ET039 : Idling adjustment ACTIVE
adjustment PR006 : Engine regime 750 < X < 775 rpm In case of a problem
PR041 : Idling regime indication = PR 006
± 25 rp m consult the
ET039 diagnostic
PR022 : RCO idling Values specified in chapte r :
“Adaptive correction of the idling regime”
9P ressure PR001: Manifold pressure 250 < X < 500 mb In case of a problem
circuit PR016 : Atmospheric pressure X = Atmospheric consult the
pressur e PR001 diagnostic
RECOMMENDAT IONS The values show n on this conformity checking are only as indication.
Performing conditions : Warm engine at idling and no consumers.
vnx.su
Page 174 of 891

IGNITION AND INJECTION
17
17 - 80
PR030 ENRICHING ADAPTATION IN OPERATION
PR031 ENRICHING ADAPTATION AT IDLING
RECOMMEND AT IONS No failure must be present or memorized.
Perform the steps for memorizing the adaptation values by the injection
computer.
Erase the computer memory. A t warm, when idling adjustment, observe the se paramete rs :
- If one of t hese parameters is moving towards the minimal limit, there is not sufficient petrol or there
is t oo much air.
- If one of the se paramete rs is moving towards the minimal limit, there is too much petrol or there is
not sufficient air.
(See chapter “ Enriching adaptive correction) for the exact limit values)
Ensure the cleaning condition and the good operation of :
- fuel filter
- fuel pump
- fuel circuit
- fuel tank
- air supply piping
- air filter
- spark plugs
C heck :
- Engine compressions
- Valves cle arance
- Ignition
Diagnostic – Parameters interpretation
AF TER Restart the conformity checking from the beginning.
REPARATION
vnx.su
Page 175 of 891

IGNITION AND INJECTION
17
17 - 81
AC010FUEL PUMP RELAY
RECOMMEND AT IONS No failure must be prese nt or memorized.
Before perform this checking, check the lines corresponde nce on the
electric diagram adequate to that vehic le.
Ch eck that choke sensor is in operating condition
M end the choke sensor if necessa ry.
Ch eck the continuity between ways 1 and 3 of the choke sensor.
If there is no continuity, repla ce the choke sensor.
Ch eck, under starter operation, the prese nce of the +12 volts at way 3 of t he choke sensor connector.
If there is no +12 volts, restore in function the line from way 3 of the choke sensor to pole 5 of the fuel
pump relay.
Ch eck the wiring condition and the mass presence at the fuel pump.
Ch eck the wiring insu lation and cont inuity :
Way 3 choke sensor > fuel pump
M end if necessary.
If the incident is persisting, repla ce the fuel pump.
Diagnostic – Parameters interpretation
AF TER Restart the conformity checking from the beginning.
REPARATION
vnx.su
Page 179 of 891

IGNITION AND INJECTION
17
17 - 85
ALP 2 STARTING PROBLEMS engine is not starting or is difficulty starting)
RECOMMEND AT IONS Do not consult this diagnostic but before performing a complete
checking by means of the CLI P tester.
Ch eck that starter is well operating
Ch eck there is petrol in the fuel tank (fuel indicator failure).
Ensure that vehic le is supplied with adequate fuel.
Ch eck tha t supply cir cuit hoses are not broken (espe cially further to a dismounting)
Ch eck the condition of the fuel filter
Ch eck the condition of the fuel tank
Ch eck that fuel tank aeration is taking place.
Ch eck the electric supply of the fuel pump.
Ch eck the good operation of the choke sensor.
Ch eck the motor of the idling regula tor.
In order to unblock it, you may slightly hit it.
Disconnect the connection hose between the canister purging valve and the intake manifold.
Cl amp the connection hose in order to stop the air passing.
If there are no more disturbances, the cause is the canister purging valve.
Ch eck the spark plugs and ignition coil condition
Ch eck tha t these eleme nts are specific to that vehicle.
Ch eck that the exhaust route is not clogged and the catalyst is not clogged.
Ch eck the engine compressions
Ch eck the flywheel condition
Ch eck the distribution setting on.
AFTER Perform a checking by means of the CLI P tester.
REPARATION
Fa ilure locating algorithm