fuse DAEWOO NUBIRA 2004 Service Repair Manual

DAEWOO NUBIRA 2004 Service Repair Manual NUBIRA 2004 DAEWOO DAEWOO https://www.carmanualsonline.info/img/54/56879/w960_56879-0.png DAEWOO NUBIRA 2004 Service Repair Manual

Page 1957 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual STEERING WHEEL AND COLUMN  6E – 3
DAEWOO V–121 BL4
High Lock Effort
ChecksAction
Check the lock cylinder for damage.Replace the lock cylinder.
Check the ignition switch for lack of free movement.L

Page 1983 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual HEATING AND VENTILATION SYSTEM  7A – 9
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
341.  Set the blower on maximum speed.
2.  Rotate the temperature control from full hot to
full cold.
3.  Listen

Page 1984 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7A – 10IHEATING AND VENTILATION SYSTEM
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
71.  Turn the ignition ON.
2.  Set the blower switch on 4.
3.  Check the blower motor ground.
Is ground OK?–Go

Page 2014 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7B – 12IMANUAL CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
DAEWOO V–121 BL4
V5 SYSTEM AIR CONDITIONING DIAGNOSIS
INSUFFICIENT COOLING DIAGNOSIS
Test Description
The numbers below refe

Page 2015 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual MANUAL CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM  7B – 13
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
81.  Check for a knocking noise from the A/C com-
pressor.
2.  Cycle the A/C co

Page 2026 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7B – 24IMANUAL CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
DAEWOO V–121 BL4
A/C PRESSURE TRANSDUCER
Removal Procedure
1.  Disconnect the negative battery cable.
2.  Release the connec

Page 2061 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7D – 6IAUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM
DAEWOO V–121 BL4
AUTOMATIC TEMPERATURE CONTROLLER DOES NOT
OPERATE WHEN IGNITION IS ON
StepActionValue(s)YesN

Page 2067 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7D – 12IAUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM
DAEWOO V–121 BL4
BLOWER MOTOR DOES NOT RUN AT ALL
StepActionValue(s)YesNo
11.  Turn the ignition to ON.
2.

Page 2068 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual AUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM 7D – 13
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
91.  Turn the ignition switch to OFF.
2.  Check circuit (Brown)

Page 2069 of 2643

DAEWOO NUBIRA 2004  Service Repair Manual 7D – 14IAUTOMATIC TEMPERATURE CONTROL HEATING, VENTILATION, AND AIR CONDITIONING SYSTEM
DAEWOO V–121 BL4
StepNo Yes Value(s) Action
20Repair the problem in circuit (Violet).
Is the repair complete