motor DODGE NEON 2000 Service Repair Manual

DODGE NEON 2000 Service Repair Manual NEON 2000 DODGE DODGE https://www.carmanualsonline.info/img/12/56910/w960_56910-0.png DODGE NEON 2000 Service Repair Manual

Page 1236 of 1285

DODGE NEON 2000  Service Repair Manual A/C SERVICE PORT VALVE CORES
The A/C service port valve cores are serviceable
items (Fig. 4). The high side valve is located on the
filter-drier, and the low side valve is situated on the
suction line

Page 1239 of 1285

DODGE NEON 2000  Service Repair Manual NOTE: The oil used in the compressor is ND8 PAG
R-134a refrigerant oil. Only refrigerant oil of the
same type should be used to service the system.
Do not use any other oil. The oil container should
b

Page 1240 of 1285

DODGE NEON 2000  Service Repair Manual Normally, vacuum is supplied to the actuator by
placing the Circulation control knob in the Recircula-
tion position. The Mode and the circulation control
are mechanically interlocked so the circulati

Page 1241 of 1285

DODGE NEON 2000  Service Repair Manual Fig. 11 Blower Motor Electrical Diagnosis
24 - 10 HEATING AND AIR CONDITIONINGPL
DIAGNOSIS AND TESTING (Continued)

Page 1242 of 1285

DODGE NEON 2000  Service Repair Manual BLOWER MOTOR VIBRATION AND/OR NOISE
DIAGNOSIS
The resistor block supplies the blower motor with
varied voltage (low and middle speeds) or battery
voltage (high speed).
CAUTION: Stay clear of the blowe

Page 1243 of 1285

DODGE NEON 2000  Service Repair Manual BLOWER MOTOR NOISE/VIBRATION DIAGNOSIS
24 - 12 HEATING AND AIR CONDITIONINGPL
DIAGNOSIS AND TESTING (Continued)

Page 1245 of 1285

DODGE NEON 2000  Service Repair Manual POSSIBLE LOCATIONS OR CAUSE OF
OBSTRUCTED COOLANT FLOW
(1) Pinched or kinked heater hoses.
(2) Improper heater hose routing.
(3) Plugged heater hoses or supply and return
ports at cooling system conne

Page 1247 of 1285

DODGE NEON 2000  Service Repair Manual HEATER-A/C VACUUM SYSTEM DIAGNOSIS
CONDITION POSSIBLE CAUSES CORRECTION
NO FORCED AIR IN
HEAT POSITION1. Vacuum line pinched or
leaking.
2. Faulty heat defroster or
mode door.
3. Faulty selector switc

Page 1248 of 1285

DODGE NEON 2000  Service Repair Manual gauge should return to the calibrated setting of 27
kPa (8 in. Hg.). If not there is a leak in the Actuator
Feed line.
(8) If there is no leak in the Supply line, Control,
or the Actuator Feed line, t

Page 1249 of 1285

DODGE NEON 2000  Service Repair Manual CAUTION: Do not overcharge refrigerant system,
as excessive compressor head pressure can cause
noise and system failure.
After the system has been tested for leaks and
evacuated, a refrigerant (R-134a