battery DODGE RAM 2001 Service Manual Online

DODGE RAM 2001 Service Manual Online RAM 2001 DODGE DODGE https://www.carmanualsonline.info/img/12/56914/w960_56914-0.png DODGE RAM 2001 Service Manual Online

Page 479 of 2889

DODGE RAM 2001  Service Manual Online WARNING: IF THE BATTERY SHOWS SIGNS OF
FREEZING, LEAKING OR LOOSE POSTS, DO NOT
TEST, ASSIST-BOOST, OR CHARGE. THE BATTERY
MAY ARC INTERNALLY AND EXPLODE. PERSONAL
INJURY AND/OR VEHICLE DAMAGE MAY RES

Page 480 of 2889

DODGE RAM 2001  Service Manual Online (2) Look through the battery cap holes to deter-
mine the level of the electrolyte in the battery (Fig.
6). The electrolyte should be approximately 1 centi-
meter above the battery plates or until the

Page 481 of 2889

DODGE RAM 2001  Service Manual Online NOTE: Models equipped with the diesel engine
option are equipped with two 12-volt batteries, con-
nected in parallel (positive-to-positive and negative-
to-negative). In order to ensure proper chargin

Page 482 of 2889

DODGE RAM 2001  Service Manual Online in a completely discharged battery. At first, the
charging current (amperage) will be low. As the bat-
tery charges, the specific gravity of the electrolyte
will gradually rise.
The Battery Charging T

Page 483 of 2889

DODGE RAM 2001  Service Manual Online ²Clear or Bright- Indicates a low battery elec-
trolyte level. The electrolyte level in the battery is
below the built-in indicator. A maintenance-free bat-
tery with non-removable cell caps must be

Page 484 of 2889

DODGE RAM 2001  Service Manual Online (3) Multiply the result from Step 2 by the temper-
ature correction factor (0.004):7 X 0.004 = 0.028
(4) The temperature at testing was below 26.7É C
(80É F); therefore, the temperature correction f

Page 485 of 2889

DODGE RAM 2001  Service Manual Online See the Open-Circuit Voltage Table. This voltage
reading will indicate the battery state-of-charge, but
will not reveal its cranking capacity. If a battery has
an open-circuit voltage reading of 12.4

Page 486 of 2889

DODGE RAM 2001  Service Manual Online (5) Rotate the load control knob to maintain a load
equal to 50% of the CCA rating of the battery (Fig.
15). After fifteen seconds, record the loaded voltage
reading, then return the load control knob

Page 487 of 2889

DODGE RAM 2001  Service Manual Online A vehicle that has not been operated for approxi-
mately twenty days, may discharge the battery to an
inadequate level. When a vehicle will not be used for
twenty days or more (stored), remove the IOD

Page 488 of 2889

DODGE RAM 2001  Service Manual Online place process to identify and correct all sources of
excessive IOD. It is now safe to select the lowest mil-
liampere scale of the multi-meter to check the low-
amperage IOD.
CAUTION: Do not open any