dash DODGE RAM 2003 Service Manual PDF

DODGE RAM 2003 Service Manual PDF RAM 2003 DODGE DODGE https://www.carmanualsonline.info/img/12/56913/w960_56913-0.png DODGE RAM 2003 Service Manual PDF

Page 2783 of 2895

DODGE RAM 2003  Service Manual PDF SPECIFICATIONS
TORQUE SPECIFICATIONS
DESCRIPTION N´m Ft. Lbs. In. Lbs.
A/C COMPRESSOR
CLUTCH PLATE NUT14.4 10.5 127.4
A/C COMPRESOR LINE
MANIFOLD FASTENER28 ( 6) 21 ( 4) 250 ( 50)
A/C COMPRESSOR T

Page 2790 of 2895

DODGE RAM 2003  Service Manual PDF INSTALLATION
(1) Plug the two wire harness connectors into the
back of the A/C Heater control.
(2) Position the A/C Heater control in the instru-
ment panel bezel and secure it with four screws.
Tight

Page 2791 of 2895

DODGE RAM 2003  Service Manual PDF an A/C pressure transducer voltage reading between
0.451 and 4.519 volts is required. Voltages outside
this range indicate a low or high refrigerant system
pressure condition to the Powertrain Control

Page 2797 of 2895

DODGE RAM 2003  Service Manual PDF INSTALLATION
WARNING: ON VEHICLES EQUIPPED WITH AIR-
BAGS, DISABLE THE AIRBAG SYSTEM BEFORE
ATTEMPTING ANY STEERING WHEEL, STEERING
COLUMN, OR INSTRUMENT PANEL COMPONENT
DIAGNOSIS OR SERVICE. DISCONNE

Page 2799 of 2895

DODGE RAM 2003  Service Manual PDF DISTRIBUTION
TABLE OF CONTENTS
page page
AIR OUTLETS
REMOVAL - PANEL OUTLETS.............24
INSTALLATION - PANEL OUTLETS..........24
BLEND DOOR
REMOVAL.............................24
INSTALLATION.....

Page 2800 of 2895

DODGE RAM 2003  Service Manual PDF (1) Recover refrigerant(Refer to 24 - HEATING &
AIR CONDITIONING/PLUMBING - STANDARD
PROCEDURE).
(2) Remove and disassemble the HVAC housing.
(Refer to 24 - HEATING & AIR CONDITIONING/
DISTRIBUTION/HV

Page 2801 of 2895

DODGE RAM 2003  Service Manual PDF DIAGNOSIS AND TESTING - BLOWER MOTOR
WARNING: ON VEHICLES EQUIPPED WITH AIR-
BAGS, DISABLE THE AIRBAG SYSTEM BEFORE
ATTEMPTING ANY STEERING WHEEL, STEERING
COLUMN, OR INSTRUMENT PANEL COMPONENT
DIAGNO

Page 2804 of 2895

DODGE RAM 2003  Service Manual PDF (2) Install the screws and snap clips that secure
the upper and lower HVAC housing halves to each
other. Tighten the screws to 2.2 N´m (20 in. lbs.).
(3) Install the blower motor and wheel unit in th

Page 2820 of 2895

DODGE RAM 2003  Service Manual PDF STANDARD PROCEDURE - REFRIGERANT SYS-
TEM EVACUATE)
(7) Charge the refrigerant system. (Refer to 24 -
HEATING & AIR CONDITIONING/PLUMBING -
STANDARD PROCEDURE - REFRIGERANT SYS-
TEM CHARGE)
LIQUID LIN

Page 2824 of 2895

DODGE RAM 2003  Service Manual PDF compartment. The liquid line should be hot to the
touch.
(5) Touch the liquid line near the evaporator inlet
at the rear of the engine compartment. The liquid
line should be cold to the touch.
(6) If