Power supply INFINITI FX35 2004 Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2004, Model line: FX35, Model: INFINITI FX35 2004Pages: 4449, PDF Size: 99.66 MB
Page 1477 of 4449
![INFINITI FX35 2004 Service Manual EC-136
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
POWER SUPPLY AND GROUND CIRCUITPFP:24110
Wiring DiagramABS006L7
TBWM0217E INFINITI FX35 2004 Service Manual EC-136
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
POWER SUPPLY AND GROUND CIRCUITPFP:24110
Wiring DiagramABS006L7
TBWM0217E](/img/42/57021/w960_57021-1476.png)
EC-136
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
POWER SUPPLY AND GROUND CIRCUITPFP:24110
Wiring DiagramABS006L7
TBWM0217E
Page 1478 of 4449
![INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-137
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and grou INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-137
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and grou](/img/42/57021/w960_57021-1477.png)
POWER SUPPLY AND GROUND CIRCUIT
EC-137
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00CGM
1. INSPECTION START
Start engine.
Is engine running?
Ye s o r N o
Ye s > > G O T O 8 .
No >> GO TO 2.
2. CHECK ECM POWER SUPPLY CIRCUIT-I
1. Turn ignition switch OFF and then ON.
2. Check voltage between ECM terminal 109 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector M1
15A fuse
Harness for open or short between ECM and fuse
>> Repair harness or connectors.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
1 B ECM ground[Engine is running]
Idle speedBody ground
109 W/L Ignition switch[Ignition switch: OFF]0V
[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
111 W / BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 5
11 6B/R
B/WECM ground[Engine is running]
Idle speedBody ground
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Voltage: Battery voltage
MBIB0015E
Page 1479 of 4449
![INFINITI FX35 2004 Service Manual EC-138
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
4. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. INFINITI FX35 2004 Service Manual EC-138
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
4. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body.](/img/42/57021/w960_57021-1478.png)
EC-138
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
4. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to EC-141, "
Ground Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Repair or replace ground connections.
5. CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 1, 115, 116 and body ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F102, M82
Harness for open or short between ECM and body ground
>> Repair open circuit or short to power in harness or connectors.
7. CHECK ECM POWER SUPPLY CIRCUIT-II
1. Reconnect ECM harness connector.
2. Turn ignition switch ON.
3. Check voltage between IPDM E/R connector E7 terminal 17 and
ground with CONSULT-II or tester.
OK or NG
OK >> Go to EC-585, "IGNITION SIGNAL" .
NG >> GO TO 8.
PBIB2195E
Continuity should exist.
Voltage: Battery voltage
PBIB1610E
Page 1480 of 4449
![INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-139
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
8. CHECK ECM POWER SUPPLY CIRCUIT-III
1. Turn ignition switch ON and then OFF.
2. Check INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-139
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
8. CHECK ECM POWER SUPPLY CIRCUIT-III
1. Turn ignition switch ON and then OFF.
2. Check](/img/42/57021/w960_57021-1479.png)
POWER SUPPLY AND GROUND CIRCUIT
EC-139
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
8. CHECK ECM POWER SUPPLY CIRCUIT-III
1. Turn ignition switch ON and then OFF.
2. Check voltage between ECM terminals 119, 120 and ground
with CONSULT-II or tester.
OK or NG
OK >> GO TO 17.
NG (Battery voltage does not exist.)>>GO TO 9.
NG (Battery voltage exists for more than a few seconds.)>>GO TO
17.
9. CHECK ECM POWER SUPPLY CIRCUIT-IV
1. Turn ignition switch OFF, and wait at least 10 seconds.
2. Check voltage between ECM terminal 111 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 10.
NG >> GO TO 12.
10. CHECK ECM POWER SUPPLY CIRCUIT-V
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E7.
3. Check harness continuity between ECM terminals 119, 120 and IPDM E/R terminal 18.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 15.
NG >> GO TO 11.
11 . DETECT MALFUNCTIONING PART
Check the following.
Harness or connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors. Voltage: After turning ignition switch OFF, battery
voltage will exist for a few seconds, then
drop approximately 0V.
PBIB1630E
Voltage: Battery voltage
PBIB1191E
Continuity should exist.
Page 1481 of 4449
![INFINITI FX35 2004 Service Manual EC-140
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
12. CHECK ECM POWER SUPPLY CIRCUIT-VI
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connect INFINITI FX35 2004 Service Manual EC-140
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
12. CHECK ECM POWER SUPPLY CIRCUIT-VI
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connect](/img/42/57021/w960_57021-1480.png)
EC-140
[VQ35DE]
POWER SUPPLY AND GROUND CIRCUIT
Revision: 2004 November 2004 FX35/FX45
12. CHECK ECM POWER SUPPLY CIRCUIT-VI
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E9.
3. Check harness continuity between ECM terminal 111 and IPDM E/R terminal 46.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
13. DETECT MALFUNCTIONING PART
Check the following.
Harness or connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK 20A FUSE
1. Disconnect 20 A fuse from IPDM E/R.
2. Check 20A fuse.
OK or NG
OK >> GO TO 17.
NG >> Replace 20A fuse.
15. CHECK GROUND CONNECTIONS
Loosen and retighten ground three screws on the body. Refer to EC-141, "
Ground Inspection" .
OK or NG
OK >> GO TO 16.
NG >> Repair or replace ground connections.
16. CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-II
1. Check harness continuity between ECM terminals 1, 115, 116 and body ground.
Refer to Wiring Diagram.
2. Also check harness for short to power.
OK or NG
OK >> GO TO 17.
NG >> Repair open circuit or short to power in harness.Continuity should exist.
PBIB2195E
Continuity should exist.
Page 1482 of 4449
![INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-141
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
17. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT I INFINITI FX35 2004 Service Manual POWER SUPPLY AND GROUND CIRCUIT
EC-141
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
17. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT I](/img/42/57021/w960_57021-1481.png)
POWER SUPPLY AND GROUND CIRCUIT
EC-141
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
17. CHECK INTERMITTENT INCIDENT
Refer to EC-135, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> Replace IPDM E/R.
NG >> Repair open circuit or short to power in harness or connectors.
Ground Inspection ABS00CGN
Ground connections are very important to the proper operation of electrical and electronic circuits. Ground
connections are often exposed to moisture, dirt and other corrosive elements. The corrosion (rust) can
become an unwanted resistance. This unwanted resistance can change the way a circuit works.
Electronically controlled circuits are very sensitive to proper grounding. A loose or corroded ground can drasti-
cally affect an electronically controlled circuit. A poor or corroded ground can easily affect the circuit. Even
when the ground connection looks clean, there can be a thin film of rust on the surface.
When inspecting a ground connection follow these rules:
Remove the ground bolt or screw.
Inspect all mating surfaces for tarnish, dirt, rust, etc.
Clean as required to assure good contact.
Reinstall bolt or screw securely.
Inspect for “add-on” accessories which may be interfering with the ground circuit.
If several wires are crimped into one ground eyelet terminal, check for proper crimps. Make sure all of the
wires are clean, securely fastened and providing a good ground path. If multiple wires are cased in one
eyelet make sure no ground wires have excess wire insulation.
For detailed ground distribution information, refer to PG-31, "
Ground Distribution" .
PBIB1870E
Page 1496 of 4449
![INFINITI FX35 2004 Service Manual DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-155
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 ha INFINITI FX35 2004 Service Manual DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-155
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 ha](/img/42/57021/w960_57021-1495.png)
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-155
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S1 terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E18, F48
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair harness or connectors.
4. CHECK HO2S1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.Voltage: Battery voltage
PBIB1559E
PBIB0969E
DTCTe r m i n a l s
Bank
ECM Sensor
P0031, P0032 24 3 1
P0051, P0052 2 3 2
Continuity should exist.
Page 1504 of 4449
![INFINITI FX35 2004 Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-163
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 ha INFINITI FX35 2004 Service Manual DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-163
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 ha](/img/42/57021/w960_57021-1503.png)
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-163
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S2 terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
IPDM E/R connector E7
10A fuse
Harness for open or short between heated oxygen sensor 2 and fuse
>> Repair harness or connectors.
4. CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1576E
Voltage: Battery voltage
PBIB0969E
DTCTe r m i n a l s
Bank
ECM Sensor
P0037, P0038 25 3 1
P0057, P0058 6 3 2
Continuity should exist.
Page 1510 of 4449
![INFINITI FX35 2004 Service Manual DTC P0101 MAF SENSOR
EC-169
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION INFINITI FX35 2004 Service Manual DTC P0101 MAF SENSOR
EC-169
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION](/img/42/57021/w960_57021-1509.png)
DTC P0101 MAF SENSOR
EC-169
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00CGP
1. INSPECTION START
Which malfunction (A or B) is duplicated?
A or B
A>>GO TO 3.
B>>GO TO 2.
2. CHECK INTAKE SYSTEM
Check the following for connection.
Air duct
Va c u u m h o s e s
Intake air passage between air duct and intake manifold
OK or NG
OK >> GO TO 3.
NG >> Reconnect the parts.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
51 L/W Mass air flow sensor[Engine is running]
Warm-up condition
Idle speed0.9 - 1.2V
[Engine is running]
Warm-up condition
Engine speed is 2,500 rpm1.6 - 1.9V
67 B/WSensor ground
(Mass air flow sensor)[Engine is running]
Warm-up condition
Idle speedApproximately 0V
111 W / BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
Page 1511 of 4449
![INFINITI FX35 2004 Service Manual EC-170
[VQ35DE]
DTC P0101 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
3. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to E INFINITI FX35 2004 Service Manual EC-170
[VQ35DE]
DTC P0101 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
3. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to E](/img/42/57021/w960_57021-1510.png)
EC-170
[VQ35DE]
DTC P0101 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
3. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten ground three screws on the body. Refer to EC-141, "
Ground Inspection" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace ground connections.
4. CHECK MAF SENSOR POWER SUPPLY CIRCUIT
1. Disconnect mass air flow (MAF) sensor harness connector.
2. Turn ignition switch ON.
3. Check voltage between MAF sensor terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
5. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness connectors M82, F102
Joint connector-3
Harness for open or short between IPDM E/R and mass air flow sensor
Harness for open or short between mass air flow sensor and ECM
>> Repair harness or connectors.
PBIB2195E
PBIB1565E
Voltage: Battery voltage
PBIB1168E