DESCRIPTION
General
The variable compressor is a swash plate type that changes piston stroke in response to the required cooling
capacity.
The tilt of the wobble (swash) plate allows the piston’s stroke to change so that refrigerant discharge continu-
ously change from 14.5 to 184 cm
3 (0.885 to 11.228 cu in).
RJIA1260E
Page 470 of 4462

ATC-24
REFRIGERATION SYSTEM
Revision: 2006 December 2006 FX35/FX45
Operation
1. Control Valve
–By changing high-pressure valve lift amount, built-in electronic control valve executes the following:
Controls high-pressure valve discharge amount.
Changes crankcase pressure in compressor.
Changes angle of wobble (swash) plate.
–Amount of high-pressure valve lift is determined by factors below.
Low-pressure applied to diaphragm
Spring load of set spring
Balance of magnetic force generated in magnet coil
–Electronic control valve (ECV) magnet coil receives electric signal (duty control) from unified meter and A/
C amp. Then, magnetic force generated by electric current is changed to control high-pressure valve lift
amount.
2. Maximum Cooling High-pressure valve is closed by magnetic force generated by electric signal sent from unified meter and
A/C amp. At this time, cylinder moves full stroke due to pressure balance between inside crankcase (Pc)
and suction line (Ps).
Under this condition, the wobble (swash) plate is set to the maximum stroke position.
3. Capacity Control When no electric signal is sent from unified meter and A/C amp. (current: OFF), high-pressure valve is
opened by spring force.
Since suction pressure is low, it makes the suction port close and the discharge port open. Thus, crank-
case pressure becomes high as high-pressure enters the crankcase.
–The force acts around the journal pin near the wobble (swash) plate, and is generated by the pressure dif-
ference before and behind the piston.
–The drive lug and journal pin are located where the piston generates the highest pressure. Piston pres-
sure is between suction pressure Ps and discharge pressure Pd, which is close to suction pressure Ps. If
crankcase pressure Pc rises due to capacity control, the force around the journal pin makes the wobble
(swash) plate angle decrease and also the piston stroke decrease. In other words, crankcase pressure
SJIA0547E
Page 473 of 4462

LUBRICANT ATC-27
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 December 2006 FX35/FX45
LUBRICANTPFP:KLG00
Maintenance of Lubricant Quantity in CompressorNJS000DL
The lubricant in the compressor circulates through the system with the refrigerant. Add lubricant to compres-
sor when replacing any component or after a large refrigerant leakage occurred. It is important to maintain the
specified amount.
If lubricant quantity is not maintained properly, the following malfunctions may result:
Lack of lubricant: May lead to a seized compressor.
Excessive lubricant: Inadequate cooling (thermal exchange interference)
LUBRICANT
LUBRICANT RETURN OPERATION
Adjust the lubricant quantity according to the test group shown below.
1. CHECK LUBRICANT RETURN OPERATION
Can lubricant return operation be performed?
A/C system works properly.
There is no evidence of a large amount of lubricant leakage.
CAUTION:
If excessive lubricant leakage is noted, never perform the lubricant return operation.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. PERFORM LUBRICANT RETURN OPERATION, PROCEEDING AS FOLLOWS
1. Start the engine, and set to the following conditions:
–Engine speed: Idling to 1,200 rpm
–A/C switch: ON
–Blower speed: Max. position
–Temp. control: Optional [Set so that intake air temperature is 25 to 30 °C (77 to 86 °F).]
–Intake position: Recirculation (REC)
2. Perform lubricant return operation for about 10 minutes.
3. Stop the engine.
>> GO TO 3.
3. CHECK REPLACEMENT PART
Should the compressor be replaced?
YES >> GO TO AT C - 2 9 , "LUBRICANT ADJUSTING PROCEDURE FOR COMPRESSOR REPLACE-
MENT" .
NO >> GO TO AT C - 2 8 , "
LUBRICANT ADJUSTING PROCEDURE FOR COMPONENTS REPLACE-
MENT EXCEPT COMPRESSOR" .
Name : NISSAN A/C System Oil Type S
Page 478 of 4462

ATC-32
AIR CONDITIONER CONTROL
Revision: 2006 December 2006 FX35/FX45
Stop Signal:
At the end of each transmission, a stop operation, in-operation, or internal malfunction message is delivered to
the unified meter and A/C amp. This completes one data transmission and control cycle.
AIR MIX DOOR CONTROL (AUTOMATIC TEMPERATURE CONTROL)
The air mix doors are automatically controlled so that in-vehicle temperature is maintained at a predetermined
value by the temperature setting, ambient temperature, in-vehicle temperature and amount of sunload.
FAN SPEED CONTROL
Blower speed is automatically controlled by the temperature setting, ambient temperature, in-vehicle tempera-
ture, intake temperature, amount of sunload and air mix door position.
With pressing AUTO switch, the blower motor starts to gradually increase air flow volume.
When engine coolant temperature is low, the blower motor operation is delayed to prevent cool air from flow-
ing.
INTAKE DOOR CONTROL
The intake doors are automatically controlled by the temperature setting, ambient temperature, in-vehicle tem-
perature, intake temperature, amount of sunload and ON/OFF operation of the compressor.
MODE DOOR CONTROL
The mode door is automatically controlled by the temperature setting, ambient temperature, in-vehicle temper-
ature, intake temperature and amount of sunload.
RJIA1749E
Page 487 of 4462

TROUBLE DIAGNOSIS ATC-41
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 December 2006 FX35/FX45
SYMPTOM TABLE
Symptom Reference Page
A/C system does not come on. Go to Trouble Diagnosis Procedure for A/C System. ATC-62, "
Power
Supply and Ground
Circuit for Auto
Amp."
A/C system cannot be controlled.Go to Integrated Display System.
Go to Navigation System. AV- 8 4 , "
Unable to
Operate System
with A/C and AV
Switch" (Without
navigation system)
or AV-139, "
Unable
to Operate System
with A/C and AV
Switch" (With navi-
gation system)
Air outlet does not change. Go to Trouble Diagnosis Procedure for Mode Door Motor. (LAN) ATC-68, "
Mode
Door Motor Circuit"Mode door motor does not operate normally.
Discharge air temperature does not change. Go to Trouble Diagnosis Procedure for Air Mix Door Motor.
(LAN) AT C - 7 1 , "
Air Mix
Door Motor Circuit"Air mix door motor does not operate nor-
mally.
Intake door does not change. Go to Trouble Diagnosis Procedure for Intake Door Motor. (LAN) AT C - 7 4 , "
Intake
Door Motor Circuit"Intake door motor does not operate nor-
mally.
Blower motor operation is malfunctioning. Go to Trouble Diagnosis Procedure for Blower Motor. ATC-77, "
Blower
Motor Circuit"
Magnet clutch does not engage. Go to Trouble Diagnosis Procedure for Magnet Clutch.AT C - 8 2 , "Magnet
Clutch Circuit"
Insufficient cooling Go to Trouble Diagnosis Procedure for Insufficient Cooling.
ATC-90, "
Insufficient
Cooling"
Go to Diagnosis Procedure for Insufficient Cooling. ATC-97, "
DIAGNO-
SIS PROCEDURE
FOR INSUFFI-
CIENT COOLING"
Insufficient heating Go to Trouble Diagnosis Procedure for Insufficient Heating.
ATC-99, "Insufficient
Heating"
Noise Go to Trouble Diagnosis Procedure for Noise.
ATC-100, "Noise"
Self-diagnosis cannot be performed. Go to Trouble Diagnosis Procedure for Self-diagnosis. ATC-101, "Self-
diagnosis"
Memory function does not operate. Go to Trouble Diagnosis Procedure for Memory Function.
ATC-102, "Memory
Function"
Page 506 of 4462

ATC-60
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
Operational CheckNJS000E1
The purpose of the operational check is to check if the individual system operates properly.
CHECKING MEMORY FUNCTION
1. Press the temperature control (UP) switch (driver side) until 32 °C (90 °F) is displayed.
2. Press OFF switch.
3. Turn ignition switch OFF.
4. Turn ignition switch ON.
5. Press the AUTO switch.
6. Confirm that the set temperature remains at previous temperature.
7. Press OFF switch.
If NG, go to trouble diagnosis procedure for ATC-102, "
Memory Function" .
If OK, continue the check.
CHECKING BLOWER
1. Press fan (UP:+) switch. Blower should operate on low speed. The fan symbol should have one blade lit.
2. Press fan (UP:+) switch again, and continue checking blower speed and fan symbol until all speeds are checked.
3. Leave blower on max. speed.
If NG, go to trouble diagnosis procedure for AT C - 7 7 , "
Blower Motor Circuit" .
If OK, continue the check.
CHECKING DISCHARGE AIR
1. Press MODE switch and DEF switch.
2. Each position indicator should change shape.
3. Confirm that discharge air comes out according to the air distri- bution table. Refer to AT C - 3 7 , "
Discharge Air Flow" .
If NG, go to trouble diagnosis procedure for AT C - 6 8 , "
Mode Door
Motor Circuit" .
If OK, continue the check.
NOTE:
Confirm that the compressor clutch is engaged (sound or visual
inspection) and intake door position is at FRESH when the D/F or
DEF is selected.
CHECKING INTAKE AIR
1. Press intake switch. Recirculation indicator should illuminate.
2. Press intake switch again. Fresh indicator should illuminate.
3. Listen for intake door position change. (Slight change of blower sound can be heard.)
If NG, go to trouble diagnosis procedure for AT C - 7 4 , "
Intake Door Motor Circuit" .
If OK, continue the check.
NOTE:
Confirm that the compressor clutch is engaged (sound or visual inspection) and intake door position is at
FRESH when the D/F or DEF is selected.
CHECKING TEMPERATURE DECREASE
1. Press temperature control (DOWN) switch (driver side) until 18 °C (60 °F) is displayed.
2. Check for cold air at discharge air outlets.
If NG, go to trouble diagnosis procedure for AT C - 9 0 , "
Insufficient Cooling" .
If OK, continue the check.
CHECKING TEMPERATURE INCREASE
1. Press temperature control (UP) switch (driver side) until 32 °C (90 °F) is displayed.
Conditions : Engine running at normal operating temperature
SJIA0302E
Page 516 of 4462

ATC-70
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
Mode Door Control Specification
COMPONENT DESCRIPTION
Mode Door Motor
The mode door motor is attached to the heater & cooling unit assem-
bly. It rotates so that air is discharged from the outlet set by the uni-
fied meter and A/C amp. Motor rotation is conveyed to a link which
activates the mode door.
DIAGNOSIS PROCEDURE FOR MODE DOOR MOTOR
SYMPTOM: Mode door motor does not operate normally.
Perform diagnosis procedure. Refer to AT C - 6 4 , "
DIAGNOSIS PROCEDURE FOR LAN CIRCUIT" .
RJIA1778E
RJIA0890E
Page 519 of 4462

TROUBLE DIAGNOSIS ATC-73
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 December 2006 FX35/FX45
COMPONENT DESCRIPTION
Air Mix Door Motor
The air mix door motor is attached to the heater & cooling unit
assembly. It rotates so that the air mix door is opened or closed to a
position set by the unified meter and A/C amp. Motor rotation is then
conveyed through a shaft and the air mix door position feedback is
then sent to the unified meter and A/C amp. by PBR built-in air mix
door motor.
DIAGNOSIS PROCEDURE FOR AIR MIX DOOR MOTOR
SYMPTOM: Discharge air temperature does not change.
Perform diagnosis procedure. Refer to AT C - 6 4 , "
DIAGNOSIS PROCEDURE FOR LAN CIRCUIT" .
Air Mix Door Motor PBR CircuitNJS000E6
SYMPTOM
Discharge air temperature does not change.
PBR circuit is open or shorted.
DIAGNOSIS PROCEDURE FOR AIR MIX DOOR MOTOR PBR
Perform diagnosis procedure. Refer to AT C - 6 4 , "DIAGNOSIS PROCEDURE FOR LAN CIRCUIT" .
RJIA0893E
RJIA0894E
Page 525 of 4462

TROUBLE DIAGNOSIS ATC-79
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 December 2006 FX35/FX45
Starting Fan Speed Control
Start up from COLD SOAK Condition (Automatic mode)
In a cold start up condition where the engine coolant temperature is below 56 °C (133 °F), the blower will not
operate for a short period of time (up to 150 seconds). The exact start delay time varies depending on the
ambient and engine coolant temperature.
In the most extreme case (very low ambient) the blower starting delay will be 150 seconds as described
above. After this delay, the blower will operate at low speed until the engine coolant temperature rises above
56 °C (133 °F), and then the blower speed will increase to the objective speed.
Start up from usual or HOT SOAK Condition (Automatic mode)
The blower will begin operation momentarily after the AUTO switch is pressed. The blower speed will gradu-
ally rise to the objective speed over a time period of 3 seconds or less (actual time depends on the objective
blower speed).
Blower Speed Compensation
Sunload
When the in-vehicle temperature and the set temperature are very close, the blower will be operating at low
speed. The low speed will vary depending on the sunload. During conditions of low or no sunload, the blower
speed is at duty ratio 25%. During high sunload conditions, the unified meter and A/C amp. raise the blower
speed (duty ratio 49%).
Fan Speed Control Specification
COMPONENT DESCRIPTION
Brush-Less Motor
The blower motor utilizes a brush-less motor with a rotating magnet.
Quietness is improved over previous motors where the brush was
the point of contact and the coil rotated.
DIAGNOSIS PROCEDURE FOR BLOWER MOTOR
SYMPTOM: Blower motor operation is malfunctioning.
RJIA1996E
ZHA152H
SJIA0266E
Page 536 of 4462

ATC-90
TROUBLE DIAGNOSIS
Revision: 2006 December 2006 FX35/FX45
Insufficient CoolingNJS000EA
SYMPTOM: Insufficient cooling
INSPECTION FLOW
SJIA1592E