DOOR LOCK/UNLOCK SWITCH LH CHECK=NBEL0115S10
1 CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
1. Disconnect smart entrance control unit connector.
2. Check continuity between control unit terminal 23 or 35 and ground.
SEL309X
Refer to wiring diagram in EL-274.
OK or NG
OK©Door lock/unlock switch is OK.
NG©GO TO 2.
2 CHECK DOOR LOCK/UNLOCK SWITCH
1. Disconnect door lock/unlock switch connector.
2. Check continuity between each door lock/unlock switch terminals.
IPower window main switch (Door lock/unlock switch LH)
SEL310X
OK or NG
OK©Check the following.
IGround circuit for door lock/unlock switch
IHarness for open or short between door lock/unlock switch and smart entrance control
unit connector
NG©Replace door lock/unlock switch.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-283
Page 1469 of 2395

FRONT LH DOOR UNLOCK SENSOR CHECK=NBEL0115S06
1 CHECK FRONT LH DOOR UNLOCK SENSOR INPUT SIGNAL
Check voltage between smart entrance control unit terminal 36 and ground.
SEL323X
Refer to wiring diagram in EL-275.
OK or NG
OK©Door unlock sensor is OK.
NG©GO TO 2.
2 CHECK FRONT LH DOOR UNLOCK SENSOR
1. Disconnect front LH door unlock sensor connector.
2. Check continuity between door unlock sensor terminals.
SEL324X
OK or NG
OK©Check the following.
IDoor unlock sensor ground circuit
IHarness for open or short between smart entrance control unit and door unlock sensor
NG©Replace door unlock sensor.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-284
Page 1470 of 2395

HAZARD REMINDER CHECK=NBEL0115S08
1 CHECK HAZARD INDICATOR
Check if hazard indicator flashes with hazard switch.
Does hazard indicator operate?
Ye s©GO TO 2.
No©Check ªhazard indicatorº circuit.
2 CHECK HAZARD REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to control unit terminal 7.
SEL325X
Refer to wiring diagram in EL-276.
OK or NG
OK©Replace smart entrance control unit.
NG©GO TO 3.
3 CHECK MULTI-REMOTE CONTROL RELAY
Check multi-remote control relay.
OK or NG
OK©GO TO 4.
NG©Replace.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-285
Page 1471 of 2395

4 CHECK POWER SUPPLY FOR MULTI-REMOTE CONTROL RELAY
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminal 1 and ground.
SEL326X
OK or NG
OK©GO TO 5.
NG©Check the following.
I15A fuse [No. 20, located in fuse block (J/B)]
IHarness for open or short between multi-remote control relay and fuse
5 CHECK MULTI-REMOTE CONTROL RELAY CIRCUIT
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminals 3 and 5.
3. Check voltage between terminals 6 and 7.
SEL327X
OK or NG
OK©Check harness for open or short between smart entrance control unit and multi-remote
control relay.
NG©Check the following.
IHarness for open or short between multi-remote control relay and fuse
IHarness for open or short between multi-remote control relay and turn signal lamps
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-286
Page 1472 of 2395

HORN REMINDER CHECK=NBEL0115S11
1 CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
Ye s©GO TO 2.
No©Check horn circuit.
2 CHECK HORN REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to smart entrance control unit terminal 19.
SEL328X
Refer to wiring diagram in EL-276.
OK or NG
OK©Replace smart entrance control unit.
NG©Check harness for open or short between smart entrance control unit and horn relay.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-287
Page 1473 of 2395

INTERIOR ROOM LAMP OPERATION CHECK=NBEL0115S09
1 CHECK INTERIOR ROOM LAMP
Check if the interior room lamp switch is in the ªONº position and the lamp illuminates.
Does interior room lamp illuminate?
Ye s©GO TO 2.
No©Check the following.
IHarness for open or short between smart entrance control unit and interior room lamp
IInterior room lamp
2 CHECK INTERIOR ROOM LAMP CIRCUIT
When interior room lamp switch is ªDOORº position, check voltage across smart entrance control unit terminal 8 and
ground.
SEL329X
Refer to wiring diagram in EL-274.
OK or NG
OK©GO TO 3.
NG©Repair harness between smart entrance control unit and interior room lamp.
3 CHECK CONTROL UNIT OUTPUT
Push unlock button of remote controller with key removed and all doors closed, and check voltage across smart entrance
control unit terminal 8 and ground.
SEL330X
OK or NG
OK©Check system again.
NG©Replace smart entrance control unit.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-288
Page 1474 of 2395

ID Code Entry Procedure=NBEL0222REMOTE CONTROLLER ID SET UP WITH CONSULT-IINBEL0222S01NOTE:
If a remote controller is lost, the ID code of the lost remote
controller must be erased to prevent unauthorized use. When
the ID code of a lost remote controller is not known, all con-
troller ID codes should be erased. After all ID codes are
erased, the ID codes of all remaining and/or new remote con-
trollers must be re-registered.
SEL331X
1. Turn ignition switch ªOFFº.
2. Connect CONSULT-II to the data link connector.
PBR455D
3. Turn ignition switch ªONº.
4. Touch ªSTARTº.
SEL332X
5. Touch ªSMART ENTRANCEº.
SEL333X
6. Touch ªMULTI REMOTE ENTº.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure
EL-289
Page 1475 of 2395

SEL334X
7. Touch ªWORK SUPPORTº.
SEL335X
8. The items are shown on the figure at left can be set up.
IªREMO CONT ID CONFIRº
Use this mode to confirm if a remote controller ID code is reg-
istered or not.
IªREMO CONT ID REGISTº
Use this mode to register a remote controller ID code.
NOTE:
Register the ID code when remote controller or smart entrance
control unit is replaced, or when additional remote controller
is required.
IªREMO CONT ID ERASURº
Use this mode to erase a remote controller ID code.
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-290
Page 1476 of 2395

REMOTE CONTROLLER ID SET UP WITHOUT
CONSULT-II
NBEL0222S03
SEL332WA
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-291
Page 1477 of 2395

NOTE:
IIf a remote controller is lost, the ID code of the lost remote
controller must be erased to prevent unauthorized use. A spe-
cific ID code can be erased with CONSULT-II. However, when
the ID code of a lost remote controller is not known, all con-
troller ID codes should be erased. After all ID codes are
erased, the ID codes of all remaining and/or new remote con-
trollers must be re-registered.
To erase all ID codes in memory, register one ID code (remote
controller) four times. After all ID codes are erased, the ID
codes of all remaining and/or new remote controllers must be
re-registered.
IWhen registering an additional remote controller, the existing
ID codes in memory may or may not be erased. If four ID
codes are stored in memory, when an additional code is
registered, only the oldest code is erased. If less than four ID
codes are stored in memory, when an additional ID code is
registered, the new ID code is added and no ID codes are
erased.
IIf you need to activate more than two additional new remote
controllers, repeat the procedure ªAdditional ID code entryº for
each new remote controller.
IEntry of maximum four ID codes is allowed. When more than
four ID codes are entered, the oldest ID code will be erased.
IEven if the same ID code that is already in the memory is input,
the same ID code can be entered. The code is counted as an
additional code.
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-292