Page 831 of 3371

BL-66
REMOTE KEYLESS ENTRY SYSTEM
Revision: August 20072004 QX56
2. CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should
be turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-19, "
Removal and Installation
of BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-60, "
Trouble
Diagnoses" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-60, "
Trouble Diagnoses" .
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-71, "
ID Code Entry Procedure" .
Remote Keyless Entry Receiver System CheckEIS005X1
1. REMOTE KEYLESS ENTRY RECEIVER SIGNAL
Check signal voltage waveform between BCM connector M18 termi-
nal 20 and ground using an oscilloscope.
OK or NG
OK >> Remote keyless entry receiver signal power supply, ground and signal circuits are OK. Replace
BCM. Refer to BCS-19, "
Removal and Installation of BCM" .
NG >> GO TO 2.Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK
turns to ON 3 seconds
after UNLOCK button
is pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Condition:
Keyfob buttons released : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .
Keyfob buttons pressed : Refer to BL-53, "
Te r m i -
nals and Reference Value
for BCM" .LIIA1275E
Page 854 of 3371

VEHICLE SECURITY (THEFT WARNING) SYSTEM
BL-89
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
CONSULT-II APPLICATION ITEM
Data Monitor
Active Test
Work Support
Monitored Item Description
DOOR SW-AS Indicates [ON/OFF] condition of front door switch RH.
DOOR SW-RR Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW-RL Indicates [ON/OFF] condition of rear door switch LH.
DOOR SW-DR Indicates [ON/OFF] condition of front door switch LH.
BACK DOOR SW Indicates [ON/OFF] condition of back door latch.
TRNK OPEN MNTR Indicates [ON/OFF] condition of glass hatch ajar switch.
ACC ON SW Indicates [ON/OFF] condition of ignition switch in ACC position.
IGN ON SW Indicates [ON/OFF] condition of ignition switch in ON position.
KEYLESS UNLOCK Indicates [ON/OFF] condition of unlock signal from keyfob.
KEYLESS LOCK Indicates [ON/OFF] condition of lock signal from keyfob.
KEY CYL LK-SW Indicates [ON/OFF] condition of lock signal from door key cylinder switch.
KEY CYL UN-SW Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
KEYLESS PBD Indicates [ON/OFF] condition of unlock signal from door key cylinder switch.
CDL UNLOCK SW Indicates [ON/OFF] condition of unlock signal from lock/unlock switch.
CDL LOCK SW Indicates [ON/OFF] condition of lock signal from lock/unlock switch.
HOOD SW Indicates [ON/OFF] condition of hood switch.
Test Item Description
THEFT INDThis test is able to check security indicator lamp operation. The lamp will be turned on when “ON”
on CONSULT-II screen is touched.
HEADLAMP (HI)This test is able to check vehicle security lamp operation. The highbeam headlamps will be acti-
vated for 0.5 seconds after “ON” on CONSULT-II screen is touched.
VEHICLE SECURITY HORNThis test is able to check vehicle security horn operation. The horns will be activated for 0.5 sec-
onds after “ON” on CONSULT-II screen is touched.
Test Item Description
SECURITY ALARM SET This mode can confirm and change security alarm ON-OFF setting.
THEFT ALM TRGThe switch which triggered vehicle security alarm is recorded. This mode is able to confirm and
erase the record of vehicle security alarm. The trigger data can be erased by touching “CLEAR”
on CONSULT-II screen.
Page 870 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-105
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Auto Back Door Operation Enable Conditions
Control When Operating Enable Conditions Not Met During Power Open/Close
Control When Operating Enable Conditions No Longer Met
Operation Power liftgate switch Remote keyless entry Back door handle switchBack door
close switch
Operating
directionFully closed →
openFully open →
closedFully closed →
openFully open
→ closedFully closed →
openFully open →
closedFully open →
closed
Disable
switchON or OFF OFF OFF
Vehicle stop
conditionA/T selector
lever in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch
in OFF position—A/T selector
lever in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch
in OFF position—A/T selector
lever in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch
in OFF position——
Battery volt-
ageApprox. 11V or more
Back door
lock status— — — — Unlocked — —
Glass hatch Closed
Items Operation condition Not met case Control
A/T selector lever P positionP or N position with ignition ON
or any position with ignition
OFFOtherContinue power open or close,
but sounds warning chime.
Back door disable switch OFF ON
Cancels power open/close
operation or door will release to
manual mode. Voltage drop 11V or more11 > V > 9
9 > V > reset voltage
Reset voltage > V No power function available
Handle switch Normal (GND) Error (OPEN)No operation. Cancel power
open/close release to manual.
Glass hatch Closed OFFCancels power door open oper-
ation, door will release to man-
ual mode.
Description Operation Control
Back door disable switch turned ONWarning chime active
→ Shift to manual mode after full open or
close operation is complete
(Recovery to power mode when main
switch turned OFF or door fully closed)→ Shift to manual mode
A/T selector lever P or N position with igni-
tion switch ONWarning chime active and one-way opera-
tion continuous
(Warning chime inactive and door fully
open or fully closed or operating conditions
recovered)Full open: power close operation allowed
Full close: operating conditions not met →
no power open function.
Voltage drop 11 - 9VOne-way operation continued (equivalent
to the case of starting voltage ← 11V for
handle operation with warning chime
active)Not allowed
Voltage drop less than 9V
(Microcomputer reset voltage - clutch hold
voltage)
Motor stopped
Clutch may slip
Control not possible because microcom-
puter being resetControl not possible because microcom-
puter being reset
Page 871 of 3371

BL-106
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
Warning Chime Active Conditions
The warning chime uses two types of audio warnings, a friendly chime and a warning chime. The friendly
chime consists of dings lasting 0.66 seconds each immediately followed by the next ding. The warning chime
consists of beeps lasting 0.33 seconds with a pause of 0.33 seconds between each beep.
Reverse Conditions
Operation status Operation or conditions Warning chime pattern
When auto operation startsPower liftgate switch operation
Friendly chime
2 seconds, 3 dings Remote keyless entry operation
Back door handle switch operation
Back door close switch operation
When reverse operation startsWhen reverse request is detected from
power liftgate switch, remote keyless
entry or back door close switchFriendly chime
1.3 seconds, 2 dings
When obstacle is detectedWarning chime
2 seconds, 3 beeps
Operating at low voltage While opening or closing Warning chime
2 seconds, 3 beeps
A/T selector lever not in P positionBack door close operationFriendly chime
Continuously dings
Back door open operationWarning chime
Continuously beeps
(until close operation is started)
Type Overload reverse
Operation covered Both directions
Detection methodOperation speed and motor current change direction
Pinch strips during back door close operation
Non-reversed area
For about 0.5 seconds immediately after drive motor operation
starts
Between full open and approx. 7° from full open
Closure operation area (half switch - close switch)
Number of times reverse allowedOne reversal is allowed (if a second obstacle is detected during a
power open or close operation, the door reverts to manual
mode).
Page 880 of 3371

AUTOMATIC BACK DOOR SYSTEM
BL-115
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Trouble Diagnosis ProcedureEIS002T0
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
4. Perform self-diagnosis procedures. Refer to BL-115, "
Self-Diagnosis Procedures" .
5. Refer to diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-116, "
Diag-
nosis Chart" .
6. Inspection End.
Self-Diagnosis ProceduresEIS005X4
INPUT SIGNAL CHECK MODE
Input signal check mode allows testing of switch input signal to the back door control unit.
To activate input signal check mode on the automatic back door, perform the following steps:
1. Turn ignition switch OFF.
2. Turn back door close switch to CANCEL (system cancelled).
3. Place A/T selector lever in P position.
4. Using the inside emergency release lever, open the back door.
5. Have an assistant press and hold the back door handle switch.
6. While the assistant continues to hold the back door handle switch, turn ignition switch ON (DO NOT start
engine).
7. After approximately 5 seconds, the back door warning chime will sound for 0.5 seconds.
8. Release the back door handle switch.
9. Within 8 seconds of the back door warning chime sounding, press and hold the power liftgate switch.
10. After approximately 5 seconds, the back door warning chime will sound for 1 second.
11. Release the power liftgate switch.
12. The input signal check mode is now initialized.
The input signal check mode can test the following inputs. The back door warning chime will sound for approx-
imately 0.5 seconds each time a switch signal input occurs. Use this test when one of these inputs is not
responding during normal automatic back door operation.
*Back door warning chime should sound as soon as vehicle moves.
Turn ignition switch OFF to end input signal check mode.
OPERATING CHECK MODE
Operating check mode allows self-diagnosis of the automatic back door system.
To activate operating check mode on the automatic back door, perform the following steps:
1. Turn ignition switch OFF.
2. Turn back door close switch to CANCEL (system cancelled).
3. Place A/T selector lever in P position.
Switch signal Operation Refer to
Power liftgate switch OFF → ONBL-118
Back door close switch (CLOSE) OFF → ONBL-120
Back door close switch (CANCEL) OFF → ONBL-121
Back door handle switch OFF → ONBL-127
Glass switch OFF → ONBL-36
A/T device (park switch) P position → other than P positionAT- 1 9 1
Vehicle speed* Vehicle speedAT-6 8
Remote keyless entry signal Keyfob switch OFF → ONBL-66
Door lock/unlock signal LOCK → UNLOCKBL-34
Pinch strip LH signal OFF → ONBL-122
Pinch strip RH signal OFF → ONBL-122
Page 881 of 3371

BL-116
AUTOMATIC BACK DOOR SYSTEM
Revision: August 20072004 QX56
4. Using the inside emergency release lever, open the back door.
5. Have an assistant press and hold the back door handle switch.
6. While the assistant continues to hold the back door handle switch, turn ignition switch ON (DO NOT start
engine).
7. After approximately 5 seconds, the back door warning chime will sound for 0.5 seconds.
8. Release the back door handle switch.
9. Within 8 seconds of the back door warning chime sounding, press the power liftgate switch 5 times in
rapid succession.
10. After approximately 5 seconds, the back door warning chime will sound for 1 second.
11. Release the power liftgate switch.
12. Immediately close the back door manually.
13. Press and release the power liftgate switch to activate operating check mode.
Self-diagnosis results are indicated by the back door warning chime.
Turn ignition switch OFF to end input signal check mode.
Diagnosis ChartEIS002T1
Back door warning chime order Back door warning chime length
Start self-diagnosis1.5 seconds
OK NG
1. Operating conditions diagnosis 0.5 seconds 0.2 seconds
2. Back door encoder diagnosis 0.5 seconds 0.2 seconds
3. Back door clutch diagnosis 0.5 seconds 0.2 seconds
4. Back door motor diagnosis 0.5 seconds 0.2 seconds
5. Cinch latch motor diagnosis 0.5 seconds 0.2 seconds
Restart self-diagnosis 1.5 seconds
Item NG Result Refer to
1. Operating conditions diagnosis resultOne of the following operating conditions no
longer met: ignition switch ON, back door
close switch (CANCEL) ON, A/T selector lever
in P position—
2. Back door encoder diagnosis resultSensor diagnosis/short, pulse signal, pulse
signal directionBL-117
3. Back door clutch diagnosis result Back door clutch does not operateBL-124
4. Back door motor diagnosis resultBack door motor does not operate (no operat-
ing current)BL-117
5. Cinch latch motor diagnosis resultCinch latch motor does not operate (no oper-
ating current)BL-128
Symptom Suspect systems Refer to
Automatic operations are not executed from the back door fully
closed or fully open position.
(Auto closure operates normally.)Power liftgate switch system inspectionBL-118
Park switch —
Power window serial linkBL-114
Pinch strip system inspectionBL-122
Automatic operations are not carried out together with open/close
operations.
(Manual operations are normal.)Power liftgate switch system inspectionBL-118Back door close switch system inspectionBL-120
Auto back door power supply and ground cir-
cuit system inspection.BL-117
The auto closure function does not operate.
(Stops at the halfway position for auto closing operations.)Pinch strip system inspectionBL-122
Page 916 of 3371

IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
BL-151
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Diagnostic Procedure 4EIS002TX
Self-diagnostic results:
“LOCK MODE” displayed on CONSULT-II screen
1. CONFIRM SELF-DIAGNOSTIC RESULTS
Confirm SELF-DIAGNOSTIC RESULTS “LOCK MODE” is displayed
on CONSULT-II screen.
Is CONSULT-II screen displayed as above?
Yes >> GO TO 2.
No >> GO TO BL-146, "
SYMPTOM MATRIX CHART 1" .
2. ESCAPE FROM LOCK MODE
1. Turn ignition switch OFF.
2. Turn ignition switch ON with registered key. (Do not start engine.) Wait 5 seconds.
3. Return the key to OFF position. Wait 5 seconds.
4. Repeat steps 2 and 3 twice (total of three cycles).
5. Start the engine.
Does engine start?
Yes >> System is OK (Now system is escaped from “LOCK MODE”). Clear all codes.
No >> GO TO 3.
3. PERFORM INITIALIZATION WITH CONSULT-II
Perform initialization with CONSULT-II.
For initialization, refer to “CONSULT-II Operation Manual NATS-
IVIS/NVIS”.
NOTE:
If the initialization is not completed or malfunctions, CONSULT-II
shows the message on the screen.
Can the system be initialized?
Yes >> System is OK.
No >> GO TO 4.
PIIA1264E
SEL297W
Page 1011 of 3371

BR-32
SERVICE DATA AND SPECIFICATIONS (SDS)
Revision: August 20072004 QX56
SERVICE DATA AND SPECIFICATIONS (SDS)PFP:00030
General SpecificationsEFS003PX
Unit: mm (in)
Brake PedalEFS003PY
Unit: mm (in)
Brake BoosterEFS003PZ
Unit: mm (in)
Check ValveEFS003Q0
Unit: kPa (mmHg, inHg)
Front Disc BrakeEFS003Q1
Unit: mm (in) Front brake Brake model CLZ31VC
Rotor outer diameter × thickness 320 × 26 (12.60 × 1.02)
Pad Length × width × thickness 111.0 × 73.5 × 9.5 (4.73 × 2.894 × 0.374)
Cylinder bore diameter 51 (2.01)
Rear brake Brake model AD14VE
Rotor outer diameter × thickness 320 × 14 (12.60 × 0.55)
Pad Length × width × thickness 83.0 × 33.0 × 8.5 (3.268 × 1.299 × 0.335)
Cylinder bore diameter 48 (1.89)
Control valve Valve model Electric brake force distribution
Brake booster Booster model C215T
Diaphragm diameter 215 (8.46)
Recommended brake fluidRefer to MA-10, "
RECOMMENDED FLUIDS AND LUBRI-
CANTS" .
Brake pedal height (from dash lower panel top surface) 182.3 − 192.3 (7.18 − 7.57)
Depressed pedal height [under a force of 490 N (50 kg, 110 lb)
with engine running]More than 90.3 (3.55)
Clearance between stopper rubber and the threaded end of stop
lamp switch 0.74 − 1.96 (0.029 − 0.077)
Pedal play3 − 11 (0.12 − 0.43)
Input rod installation standard dimension 15.6 − 15.9 (0.614 − 0.626)
Vacuum leakage
[at vacuum of – 66.7 (– 500, – 19.69)]Within 1.3 kPa (10 mmHg, 0.39 inHg) of vacuum for 15 seconds
Brake modelCLZ31VC
Brake padStandard thickness (new) 11.88 (0.468)
Repair limit thickness 1.0 (0.039)
Disc rotorStandard thickness (new) 26.0 (1.024)
Repair limit thickness 24.5 (0.965)
Maximum uneven wear (measured at 8 positions) 0.015 (0.0006)
Runout limit (with it attached to the vehicle) 0.04 (0.0016)
Page 1039 of 3371
![INFINITI QX56 2004 Factory Manual Online BRC-26
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Note 1: Confirm tire pressure is normal.
Note 2: ON/OFF timing of ABS warning lamp
ON: For approximately 2 seconds after ignition INFINITI QX56 2004 Factory Manual Online BRC-26
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Note 1: Confirm tire pressure is normal.
Note 2: ON/OFF timing of ABS warning lamp
ON: For approximately 2 seconds after ignition](/img/42/57034/w960_57034-1038.png)
BRC-26
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: August 20072004 QX56
Note 1: Confirm tire pressure is normal.
Note 2: ON/OFF timing of ABS warning lamp
ON: For approximately 2 seconds after ignition switch is turned ON, or when a malfunction is detected.
OFF: Approximately 2 seconds after ignition switch is turned ON (when system is in normal operation) and TCS/VDC function is not
activated.
Note 3: ON/OFF timing of VDC OFF indicator lamp
ON: For approximately 2 seconds after ignition switch is turned ON, or when a malfunction is detected and VDC OFF switch is ON.
OFF: Approximately 2 seconds after ignition switch is turned ON (when system is in normal operation.) And when VDC OFF switch is
OFF.
Note 4: SLIP indicator lamp ON/OFF timing
ON: For approximately 2 seconds after ignition switch is turned ON, or when a malfunction is detected and TCS/VDC function is acti-
vated while driving.FR LH IN SOL
FR LH OUT SOL
FR RH IN SOL
FR RH OUT SOL
RR RH IN SOL
RR RH OUT SOL
RR LH IN SOL
RR LH OUT SOLSolenoid valve opera-
tionActuator (solenoid) is active
(“ACTIVE TEST” with CON-
SULT-II) or actuator relay is
inactive (in fail-safe mode).ON
BRC-43, "
Solenoid and
VDC Change-Over Valve
System Inspection"
When actuator (solenoid) is
not active and actuator relay is
active (ignition switch ON).OFF
CV1
CV2
SV1
SV2VDC switch-over valve
statusWhen actuator (switch-over
valve) is active (“ACTIVE
TEST” with CONSULT-II) or
actuator relay is inactive (when
in fail-safe mode).ON
When actuator (switch-over
valve) is not active and actua-
tor relay is active (ignition
switch ON).OFF
DECEL G-SENLongitudinal accelera-
tion detected by Decel
G-SensorVehicle stopped Approx. 0 GBRC-41, "
Ya w R a te / S i d e /
Decel G Sensor System
Inspection"Vehicle running -1.7 to 1.7 G
PRESS SENSORBrake fluid pressure
detected by pressure
sensorDo not step on the Brake pedal
(When ignition switch is ON)Approx. 0 bar
—
Step on the Brake pedal
(When ignition switch is ON)-40 to 300 bar
FLUID LEV SWON/OFF status of
brake fluid level switchWhen brake fluid level switch
ONON
DI-31, "
WAR NIN G
LAMPS"When brake fluid level switch
OFF OFF
VDC SIGNAL
TCS SIGNAL
ABS SIGNAL
EBD SIGNALSignal statusVDC active
TCS active
ABS active
EBD activeON
VDC system
TCS system
ABS system
EBD system VDC not active
TCS not active
ABS not active
EBD not activeOFF
VDC FAIL SIG
TCS FAIL SIG
ABS FAIL SIG
EBD FAIL SIGFail signal statusVDC fail
TCS fail
ABS fail
EBD failON
VDC system
TCS system
ABS system
EBD system VDC normal
TCS normal
ABS normal
EBD normalOFF Monitor item Display contentData monitor
Note: Error inspection
checklist
ConditionReference value in
normal operation
Page 1066 of 3371
![INFINITI QX56 2004 Factory Manual Online TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS
BRC-53
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: August 20072004 QX56
4. REAR PRESSURE SENSOR INSPECTION
1. Reconnect the rear pressure sensor and INFINITI QX56 2004 Factory Manual Online TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS
BRC-53
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: August 20072004 QX56
4. REAR PRESSURE SENSOR INSPECTION
1. Reconnect the rear pressure sensor and](/img/42/57034/w960_57034-1065.png)
TROUBLE DIAGNOSIS FOR SELF-DIAGNOSTIC ITEMS
BRC-53
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: August 20072004 QX56
4. REAR PRESSURE SENSOR INSPECTION
1. Reconnect the rear pressure sensor and ABS actuator and electric unit (control unit) connectors.
2. Use "DATA MONITOR" to check if the status of "PRESS SEN 2" is normal.
OK or NG
OK >> Inspection End.
NG >> Replace rear pressure sensor.
Steering Angle Sensor Safe Mode InspectionEFS0062X
INSPECTION PROCEDURE
1. INDICATOR LAMP CHECK
Check that VDC OFF indicator lamp is on.
OK or NG
OK >> GO TO 2.
NG >> GO TO 3.
2. ADJUSTMENT OF STEERING ANGLE SENSOR NEUTRAL POSITION
Adjust steering angle sensor neutral position. Refer to BRC-62, "
Adjustment of Steering Angle Sensor Neutral
Position" .
OK or NG
OK >> GO TO 3.
NG >> Check steering angle sensor. Refer to BRC-40, "
Steering Angle Sensor System" .
3. INDICATOR LAMP CHECK
Check that VDC OFF indicator lamp is off.
OK or NG
OK >> GO TO 4.
NG >> Perform basic inspection. Refer to BRC-23, "
Basic Inspection" .
4. CHECK SELF-DIAGNOSTIC RESULTS
Perform ABS actuator and electric unit (control unit) self-diagnosis.
NOTE:
When self-diagnostic results show items other than those above, perform repair or replacement for the item
indicated and repeat self-diagnosis.
Is the above displayed on self-diagnosis display?
YES >> Erase error memory.
NO >> Inspection End.ConditionData monitor display (Approx.)
PRESS SEN 2
When brake pedal is depressed Positive value
When brake pedal is released 0 bar
Self-diagnosis results
ST ANGL SEN SAFE