ignition INFINITI QX56 2008 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2008, Model line: QX56, Model: INFINITI QX56 2008Pages: 4083, PDF Size: 81.73 MB
Page 537 of 4083
![INFINITI QX56 2008 Factory Service Manual BRC-70
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1164, C1165, C1166
, C1167 CV/SV SYSTEM
C1164, C1165, C1166, C1167 CV/SV SYSTEM
DescriptionINFOID:0000000001686335
CV1, CV2 (CUT VALVE)
The cut valve shuts INFINITI QX56 2008 Factory Service Manual BRC-70
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1164, C1165, C1166
, C1167 CV/SV SYSTEM
C1164, C1165, C1166, C1167 CV/SV SYSTEM
DescriptionINFOID:0000000001686335
CV1, CV2 (CUT VALVE)
The cut valve shuts](/img/42/57030/w960_57030-536.png)
BRC-70
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1164, C1165, C1166
, C1167 CV/SV SYSTEM
C1164, C1165, C1166, C1167 CV/SV SYSTEM
DescriptionINFOID:0000000001686335
CV1, CV2 (CUT VALVE)
The cut valve shuts off the normal brake fluid path from the master cylinder, when VDC/TCS is activated.
SV1, SV2 (SUCTION VALVE)
The suction valve supplies the brake fluid from the ma ster cylinder to the pump, when VDC/TCS is activated.
DTC LogicINFOID:0000000001686336
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK SELF-DIAGNOSIS RESULTS
Check the self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> Proceed to diagnosis procedure. Refer to BRC-70, "Diagnosis Procedure".
NO >> Inspection End
Diagnosis ProcedureINFOID:0000000001691159
INSPECTION PROCEDURE
1.CHECK CONNECTOR
1. Turn ignition switch OFF.
2. Disconnect ABS actuator and electric unit (control unit) connector.
3. Check terminal for deformation, disconnection, looseness, and so on. If any malfunction is found, re\
pair or replace terminal.
4. Reconnect connectors and then perform the self-diagnosis. Refer to BRC-24, "
CONSULT-III Function
(ABS)".
Is any item indicated on the self-diagnosis display?
YES >> GO TO 2
NO >> Poor connection of connector term inal. Repair or replace connector.
DTCDisplay item Malfunction detected condition Possible cause
C1164 CV1 VDC switch-over solenoid valve (CV1) on the primary
side is open circuit or shorted, or the control line is open
or shorted to the power supply or the ground.
• Harness or connector
• ABS actuator and electric unit (control unit)
C1165 CV2
VDC switch-over solenoid valve (CV2) on the primary
side is open circuit or shorted, or the control line is open
or shorted to the power supply or the ground.
C1166 SV1 VDC switch-over solenoid valve (SV1) on the primary
side is open circuit or shorted, or the control line is open
or shorted to the power supply or the ground.
C1167 SV2 VDC switch-over solenoid valve (SV2) on the primary
side is open circuit or shorted, or the control line is open
or shorted to the power supply or the ground.
Self-diagnosis results
CV1
CV2SV1
SV2
Revision: March 2010 2008 QX56
Page 538 of 4083
![INFINITI QX56 2008 Factory Service Manual C1164, C1165, C1166, C1167 CV/SV SYSTEM
BRC-71
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
2.CHECK SOLENOID, VDC SWITCH-OVER VALVE A ND ACTUATOR RELAY POWER SUPPLY CIRCUIT
INFINITI QX56 2008 Factory Service Manual C1164, C1165, C1166, C1167 CV/SV SYSTEM
BRC-71
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
2.CHECK SOLENOID, VDC SWITCH-OVER VALVE A ND ACTUATOR RELAY POWER SUPPLY CIRCUIT](/img/42/57030/w960_57030-537.png)
C1164, C1165, C1166, C1167 CV/SV SYSTEM
BRC-71
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
2.CHECK SOLENOID, VDC SWITCH-OVER VALVE A ND ACTUATOR RELAY POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ABS actuator and electric unit (control unit) connec- tor.
3. Check voltage between ABS actuator and electric unit (control unit) harness connector terminal and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace malfunctioning components.
3.CHECK SOLENOID, VDC SWITCH-OVER VA LVE AND ACUATOR RELAY GROUND CIRCUIT
Check continuity between ABS act uator and electric unit (control
unit) harness connector terminals and ground.
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-116, "
Removal and Installation".
NO >> Repair or replace malfunctioning components.
Component InspectionINFOID:0000000001691160
1.CHECK ACTIVE TEST
1. Select each test menu item on ”ACTIVE TEST“.
2. On the display, touch “UP”, “KEEP”, and “DOWN”, and check that the system operates as shown in the
table below.
*: ON for 1 to 2 seconds after the touch, and then OFF
ABS actuator and electric unit (control unit)
—Volt a ge
Connector Terminal
E125 32Ground Battery voltage
AWFIA0018ZZ
ABS actuator and electric unit (control unit)
—Contin u it y
Connector Terminal
E125 16, 47GroundYes
AWFIA0016ZZ
Operation ABS solenoid valve
ABS solenoid valve (ACT)
UP KEEP DOWN UP ACTUA-
TOR UP ACTUA-
TOR KEEP
FR RH SOL
FR RH ABS SOLE-
NOID (ACT) FR RH IN SOL
OFF ON ON OFF OFF OFF
FR RH OUT SOL OFF OFF ON* OFF OFF OFF
FR LH SOL
FR LH ABS SOLE-
NOID (ACT) FR LH IN SOL
OFF ON ON OFF OFF OFF
FR LH OUT SOL OFF OFF ON* OFF OFF OFF
RR RH SOL
RR RH ABS SOLE-
NOID (ACT) RR RH IN SOL
OFF ON ON OFF OFF OFF
RR RH OUT SOL OFF OFF ON* OFF OFF OFF
RR LH SOL
RR LH ABS SOLE-
NOID (ACT) RR LH IN SOL
OFF ON ON OFF OFF OFF
RR LH OUT SOL OFF OFF ON* OFF OFF OFF
REAR SOL RR RH IN SOL
OFF ON ON OFF OFF OFF
RR RH OUT SOL OFF OFF ON* OFF OFF OFF
RR LH IN SOL OFF ON ON OFF OFF OFF
RR LH OUT SOL OFF OFF ON* OFF OFF OFF
Revision: March 2010 2008 QX56
Page 540 of 4083
![INFINITI QX56 2008 Factory Service Manual C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
BRC-73
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
DescriptionINFOID:00000000016 INFINITI QX56 2008 Factory Service Manual C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
BRC-73
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
DescriptionINFOID:00000000016](/img/42/57030/w960_57030-539.png)
C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
BRC-73
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
C1178, C1181, C1184, C1189 ABS ACTIVE BOOSTER
DescriptionINFOID:0000000001686340
The active brake booster consists of a vacuum boos ter, an active booster control group and a delta stroke
sensor. If a brake booster system malfunction occurs due to loss of vacuum, the delta stroke sensor will signal
the ABS actuator and electric unit (control unit) that a booster malfunction has occurred. The active booster
then applies supplemental force to the master cylinder re lative to the amount of force exerted on the brake
pedal.
DTC LogicINFOID:0000000001686341
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK SELF-DIAGNOSIS RESULTS
Check the self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> Proceed to diagnosis procedure. Refer to BRC-73, "Diagnosis Procedure".
NO >> Inspection End
Diagnosis ProcedureINFOID:0000000001686342
INSPECTION PROCEDURE
1.CONNECTOR INSPECTION
1. Turn the ignition switch OFF.
2. Disconnect the active booster connector E49 and ABS ac tuator and electric unit (control unit) connector
E125 and inspect the terminals for deforma tion, disconnection, looseness, or damage.
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair connector.
2.ACTIVE BOOSTER CIRCUIT INSPECTION
DTC Display item Malfunction detected condition Possible cause
C1178 ABS ACTIVE BOOSTER SV
NG Active booster solenoid is malfunctioning, or signal line of
active booster servo is open or shorted.
• Harness or connector
• Active booster
• ABS actuator and electric unit (control unit)
C1181
ABS ACTIVE BOOSTER RE-
SPONSE NG Active booster response is malfunctioning, or signal line
of active booster response is open or shorted.
C1184 ABS BRAKE RELEASE SW
NG Brake release switch is malfunctioning, or signal line of
brake release switch is open or shorted.
C1189 ABS BRAKE BOOSTER DE-
FECT Brake booster is defective or malfunctioning.
Self-diagnosis results
ABS ACTIVE BOOSTER SV NG
ABS ACTIVE BOOSTER RESPONSE NG ABS BRAKE RELEASE SW NG
ABS BRAKE BOOSTER DEFECT
Revision: March 2010 2008 QX56
Page 543 of 4083
![INFINITI QX56 2008 Factory Service Manual BRC-76
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1179 ABS DELTA S SEN NG
C1179 ABS DELTA S SEN NG
DescriptionINFOID:0000000001686345
The active brake booster consists of a vacuum booster, an active booste INFINITI QX56 2008 Factory Service Manual BRC-76
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1179 ABS DELTA S SEN NG
C1179 ABS DELTA S SEN NG
DescriptionINFOID:0000000001686345
The active brake booster consists of a vacuum booster, an active booste](/img/42/57030/w960_57030-542.png)
BRC-76
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
C1179 ABS DELTA S SEN NG
C1179 ABS DELTA S SEN NG
DescriptionINFOID:0000000001686345
The active brake booster consists of a vacuum booster, an active booster control group and a delta stroke
sensor. If a brake booster system malfunction occurs due
to loss of vacuum, the delta stroke sensor will signal
the ABS actuator and electric unit (c ontrol unit) that a booster malfunction has occurred. The active booster
then applies supplemental force to the master cylinder re lative to the amount of force exerted on the brake
pedal.
DTC LogicINFOID:0000000001686346
DTC DETECTION LOGIC
DTC CONFIRMATION PROCEDURE
1.CHECK SELF-DIAGNOSIS RESULTS
Check the self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> Proceed to diagnosis procedure. Refer to BRC-76, "Diagnosis Procedure".
NO >> Inspection End
Diagnosis ProcedureINFOID:0000000001686347
INSPECTION PROCEDURE
1.CONNECTOR INSPECTION
1. Turn the ignition switch OFF.
2. Disconnect the delta stroke sensor connector E114 and ABS actuator and electric unit (control unit) con- nector E125 and inspect the terminals for def ormation, disconnection, looseness, or damage.
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair connector.
2.DELTA STROKE SENSOR CIRCUIT INSPECTION
1. Measure the continuity between ABS actuator and electric unit (control unit) harness connector E125 (A) and delta stroke sen-
sor harness connector E114 (B).
2. Measure the continuity between ABS actuator and el ectric unit (control unit) harness connector E125 (A)
and body ground.
DTC Display item Malfunction detected condition Possible cause
C1179 ABS DELTA S SEN NG Delta stroke sensor is malfunctioning, or signal line of
delta stroke sensor is open or shorted. • Harness or connector
• Delta stroke sensor
• ABS actuator and electric unit
(control unit)
Self-diagnosis results
ABS DELTA S SEN NG
ABS actuator and electric unit (control unit) Delta stroke sensor
Continuity
Connector Terminal Connector Terminal
A: E125 26
B: E114 1
Ye s
39 3
40 5
AWFIA0029ZZ
Revision: March 2010 2008 QX56
Page 547 of 4083
![INFINITI QX56 2008 Factory Service Manual BRC-80
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
U1000 CAN COMM CIRCUIT
U1000 CAN COMM CIRCUIT
DescriptionINFOID:0000000001686350
CAN (Controller Area Network) is a serial communication line for real time INFINITI QX56 2008 Factory Service Manual BRC-80
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
U1000 CAN COMM CIRCUIT
U1000 CAN COMM CIRCUIT
DescriptionINFOID:0000000001686350
CAN (Controller Area Network) is a serial communication line for real time](/img/42/57030/w960_57030-546.png)
BRC-80
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
U1000 CAN COMM CIRCUIT
U1000 CAN COMM CIRCUIT
DescriptionINFOID:0000000001686350
CAN (Controller Area Network) is a serial communication line for real time application. It is an on-vehicle mul-
tiplex communication line with high data communication s
peed and excellent error detection ability. Many elec-
tronic control units are equipped onto a vehicle, and each control unit shares information and links with other
control units during operation (not independent). In CA N communication, control units are connected with 2
communication lines (CAN H line, CAN L line) allowing a high rate of information transmission with less wiring.
Each control unit transmits/receives data but selectively reads required data only.
DTC LogicINFOID:0000000001686351
DTC DETECTION LOGIC
Diagnosis ProcedureINFOID:0000000001686352
INSPECTION PROCEDURE
1.CHECK CONNECTOR
1. Turn ignition switch OFF, disconnect the ABS actuat or and electric unit (control unit) connector, and check
the terminals for deformation, disconnection, looseness, and so on. If there is a malfunction, repair or
replace the terminal.
2. Reconnect connector and perform self-diagnosis.
Is
“CAN COMM CIRCUIT” displayed in self-diagnosis display items?
YES >> Print out the self-diagnostic results, and refer to LAN-14, "Trouble Diagnosis Flow Chart".
NO >> Connector terminal is loose, damaged, open, or shorted.
Special Repair RequirementINFOID:0000000001691168
1.ADJUSTMENT OF STEERING ANGLE SENSOR NEUTRAL POSITION
Always perform neutral position adjustment for the st eering angle sensor when replacing the ABS actuator
and electric unit (control unit). Refer to BRC-8, "
ADJUSTMENT OF STEERING ANGLE SENSOR NEUTRAL
POSITION : Description".
>> GO TO 2
2.CALIBRATION OF DECEL G SENSOR
Always perform calibration of decel G sensor when replac ing the ABS actuator and electric unit (control unit).
Refer to BRC-9, "
CALIBRATION OF DECEL G SENSOR : Description".
>> END
DTC Display item Malfunction detected condition Possible cause
U1000 CAN COMM CIRCUIT When ABS actuator and electric unit (control unit) is not
transmitting or receiving CAN communication signal for 2
seconds or more. • CAN communication line
• ABS actuator and electric unit
(control unit)
Revision: March 2010 2008 QX56
Page 548 of 4083
![INFINITI QX56 2008 Factory Service Manual VDC OFF SWITCHBRC-81
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF SWITCH
DescriptionINFOID:0000000001686354
VDC OFF switch can deactivate (t urn OFF) the VDC/TCS fun INFINITI QX56 2008 Factory Service Manual VDC OFF SWITCHBRC-81
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF SWITCH
DescriptionINFOID:0000000001686354
VDC OFF switch can deactivate (t urn OFF) the VDC/TCS fun](/img/42/57030/w960_57030-547.png)
VDC OFF SWITCHBRC-81
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF SWITCH
DescriptionINFOID:0000000001686354
VDC OFF switch can deactivate (t urn OFF) the VDC/TCS function by pressing the VDC OFF switch.
Component Function CheckINFOID:0000000001686355
1.CHECK VDC OFF SWITCH OPERATION
Turn ON/OFF the VDC OFF switch and check that the VDC OFF indicator lamp in the combination meter turns
ON/OFF correctly.
Is the inspection result normal?
YES >> Inspection End
NO >> Go to diagnosis procedure. Refer to BRC-81, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001686356
1.CHECK VDC OFF SWITCH
1. Turn ignition switch OFF.
2. Disconnect VDC OFF switch connector.
3. Check continuity between VDC OFF switch terminals.
Is the inspection result normal?
YES >> GO TO 2
NO >> Replace VDC OFF switch.
2.CHECK VDC OFF SWITCH HARNESS
1. Disconnect ABS actuator and electric unit (control unit) connec- tor.
2. Check continuity between ABS actuator and electric unit (control unit) connector E125 (A) and VDC OFF switch connector M253
(B).
3. Check continuity between ABS actuator and electric unit (control unit) connector E125 (A) and ground.
Is the inspection result normal?
YES >> GO TO 3
Condition VDC OFF indicator lamp illumination status
VDC OFF switch: ON ON
VDC OFF switch: OFF OFF
VDC OFF switch
Condition Continuity
Te r m i n a l
1 − 2 When VDC OFF switch is pressed. Yes
When VDC OFF switch is released. No
PFIA0307E
ABS actuator and electric unit
(control unit) VDC OFF switch
Continuity
Connector Terminal Connector Terminal
A: E125 38B: M253 1Yes
ABS actuator and electric unit (control unit) —Contin u it y
Connector Terminal
A: E125 38Ground No
AWFIA0030ZZ
Revision: March 2010 2008 QX56
Page 549 of 4083
![INFINITI QX56 2008 Factory Service Manual BRC-82
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
VDC OFF SWITCH
NO >> Repair or replace harness.
3.CHECK VDC OFF SWITCH GROUND
Check continuity between VDC OFF switch connector M253 and
ground.
Is the insp INFINITI QX56 2008 Factory Service Manual BRC-82
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
VDC OFF SWITCH
NO >> Repair or replace harness.
3.CHECK VDC OFF SWITCH GROUND
Check continuity between VDC OFF switch connector M253 and
ground.
Is the insp](/img/42/57030/w960_57030-548.png)
BRC-82
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
VDC OFF SWITCH
NO >> Repair or replace harness.
3.CHECK VDC OFF SWITCH GROUND
Check continuity between VDC OFF switch connector M253 and
ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair or replace harness.
4.CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to MWI-24, "
Diagnosis Descrip-
tion".
Is the inspection result normal?
YES >> Replace ABS actuator and electr ic unit (control unit). Refer to BRC-116, "Removal and Installa-
tion".
NO >> Replace combination meter. Refer to MWI-76, "
Removal and Installation".
Component InspectionINFOID:0000000001686357
INSPECTION PROCEDURE
1.CHECK VDC OFF SWITCH
1. Turn ignition switch OFF.
2. Disconnect VDC OFF switch connector.
3. Check continuity between VDC OFF switch terminals.
Is the inspection result normal?
YES >> Inspection End
NO >> Replace VDC OFF switch.
VDC OFF switch —Continuity
Connector Terminal
M253 2Ground Yes
AWFIA0031ZZ
VDC OFF switch
Condition Continuity
Te r m i n a l
1 − 2 When VDC OFF switch is pressed. Yes
When VDC OFF switch is released. No
PFIA0307E
Revision: March 2010
2008 QX56
Page 550 of 4083
![INFINITI QX56 2008 Factory Service Manual ABS WARNING LAMPBRC-83
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
ABS WARNING LAMP
DescriptionINFOID:0000000001686358
× : ON –: OFF
Component Function CheckINFOID:00000 INFINITI QX56 2008 Factory Service Manual ABS WARNING LAMPBRC-83
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
ABS WARNING LAMP
DescriptionINFOID:0000000001686358
× : ON –: OFF
Component Function CheckINFOID:00000](/img/42/57030/w960_57030-549.png)
ABS WARNING LAMPBRC-83
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
ABS WARNING LAMP
DescriptionINFOID:0000000001686358
× : ON –: OFF
Component Function CheckINFOID:0000000001686359
1.CHECK ABS WARNING LAMP OPERATION
Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End
NO >> Go to diagnosis procedure. Refer to BRC-83, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001686360
1.CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-24, "
CONSULT-III Function
(ABS)".
Is the inspection result normal?
YES >> GO TO 2
NO >> Check items displayed by self-diagnosis.
2.CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to MWI-24, "
Diagnosis Descrip-
tion".
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-116, "Removal and Installa-
tion".
NO >> Replace combination meter. Refer to MWI-76, "
Removal and Installation".
Condition ABS warning lamp
Ignition switch OFF –
For 1 second after turning ON ignition switch ×
1 second later after turning ON ignition switch –
ABS function is malfunctioning. ×
EBD function is malfunctioning. ×
Revision: March 2010 2008 QX56
Page 551 of 4083
![INFINITI QX56 2008 Factory Service Manual BRC-84
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
BRAKE WARNING LAMP
BRAKE WARNING LAMP
DescriptionINFOID:0000000001686361
×
: ON –: OFF
NOTE:
• 1: Brake warning lamp will turn on in case of parking br INFINITI QX56 2008 Factory Service Manual BRC-84
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
BRAKE WARNING LAMP
BRAKE WARNING LAMP
DescriptionINFOID:0000000001686361
×
: ON –: OFF
NOTE:
• 1: Brake warning lamp will turn on in case of parking br](/img/42/57030/w960_57030-550.png)
BRC-84
< COMPONENT DIAGNOSIS >[VDC/TCS/ABS]
BRAKE WARNING LAMP
BRAKE WARNING LAMP
DescriptionINFOID:0000000001686361
×
: ON –: OFF
NOTE:
• 1: Brake warning lamp will turn on in case of parking brake operation (when switch is ON) or of brake fluid level switch opera tion
(when brake fluid is insufficient).
• 2: After starting engine, brake warning lamp is turned off.
Component Function CheckINFOID:0000000001686362
1.BRAKE WARNING LAMP OPERATION CHECK
Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.
Is the inspection result normal?
YES >> Inspection End
NO >> Go to diagnosis procedure. Refer to BRC-84, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001691169
1.CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-24, "
CONSULT-III Function
(ABS)".
Is the inspection result normal?
YES >> GO TO 2
NO >> Check items displayed by self-diagnosis.
2.CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to MWI-24, "
Diagnosis Descrip-
tion".
Is the inspection result normal?
YES >> Replace ABS actuator and electr ic unit (control unit). Refer to BRC-116, "Removal and Installa-
tion".
NO >> Replace combination meter. Refer to MWI-76, "
Removal and Installation".
Condition Brake warning lamp (Note 1)
Ignition switch OFF –
For 1 second after turning ON ignition switch × (Note 2)
1 second later after turning ON ignition switch × (Note 2)
EBD function is malfunctioning. ×
Revision: March 2010 2008 QX56
Page 552 of 4083
![INFINITI QX56 2008 Factory Service Manual VDC OFF INDICATOR LAMPBRC-85
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF INDICATOR LAMP
DescriptionINFOID:0000000001686364
× : ON –: OFF
Component Function Check INFINITI QX56 2008 Factory Service Manual VDC OFF INDICATOR LAMPBRC-85
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF INDICATOR LAMP
DescriptionINFOID:0000000001686364
× : ON –: OFF
Component Function Check](/img/42/57030/w960_57030-551.png)
VDC OFF INDICATOR LAMPBRC-85
< COMPONENT DIAGNOSIS > [VDC/TCS/ABS]
C
D
E
G H
I
J
K L
M A
B
BRC
N
O P
VDC OFF INDICATOR LAMP
DescriptionINFOID:0000000001686364
× : ON –: OFF
Component Function CheckINFOID:0000000001686365
1.VDC OFF INDICATOR LAMP OPERATION CHECK 1
Check that the lamp illuminates for approximately 1 second after the ignition switch is turned ON.
Is the inspection result normal?
YES >> GO TO 2
NO >> Go to diagnosis procedure. Refer to BRC-85, "
Diagnosis Procedure".
2.VDC OFF INDICATOR LAMP OPERATION CHECK 2
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the
VDC OFF switch.
Is the inspection result normal?
YES >> Inspection End
NO >> Check VDC OFF switch. Refer to BRC-81, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000001686366
1.CHECK VDC OFF SWITCH
Check that the VDC OFF indicator lamp in the combination meter turns ON/OFF correctly when operating the
VDC OFF switch.
Is the inspection result normal?
YES >> GO TO 2
NO >> Check VDC OFF switch. Refer to BRC-81, "
Diagnosis Procedure".
2.CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis. Refer to BRC-24, "
CONSULT-III Function
(ABS)".
Is the inspection result normal?
YES >> GO TO 3
NO >> Check items displayed by self-diagnosis.
3.CHECK COMBINATION METER
Check if the indication and operation of combination meter are normal. Refer to MWI-24, "
Diagnosis Descrip-
tion".
Is the inspection result normal?
YES >> Replace ABS actuator and electric unit (control unit). Refer to BRC-116, "Removal and Installa-
tion".
NO >> Replace combination meter. Refer to MWI-76, "
Removal and Installation".
Condition VDC OFF indicator lamp
Ignition switch OFF –
For 1 second after turning ON ignition switch ×
1 second later after turning ON ignition switch –
VDC OFF switch turned ON. (VDC function is OFF.) ×
VDC/TCS function is malfunctioning. ×
ABS function is malfunctioning. ×
EBD function is malfunctioning. ×
Revision: March 2010 2008 QX56