air condition INFINITI QX56 2010 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2010, Model line: QX56, Model: INFINITI QX56 2010Pages: 4210, PDF Size: 81.91 MB
Page 1490 of 4210
![INFINITI QX56 2010 Factory Service Manual P0130, P0150 A/F SENSOR 1EC-137
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0130, P0150 A/F SENSOR 1
Component DescriptionINFOID:0000000005149155
The air fuel ratio (A/F) sensor INFINITI QX56 2010 Factory Service Manual P0130, P0150 A/F SENSOR 1EC-137
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0130, P0150 A/F SENSOR 1
Component DescriptionINFOID:0000000005149155
The air fuel ratio (A/F) sensor](/img/42/57032/w960_57032-1489.png)
P0130, P0150 A/F SENSOR 1EC-137
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0130, P0150 A/F SENSOR 1
Component DescriptionINFOID:0000000005149155
The air fuel ratio (A/F) sensor 1 is a planar one-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is composed an elec-
trode layer, which transports ions. It has a heater in the element.
The sensor is capable of precise m
easurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range.
The exhaust gas components diffuse through the diffusion layer at
the sensor cell. An electrode layer is applied voltage, and this current
relative oxygen density in lean. Also this current relative hydrocar-
bon density in rich.
Therefore, the A/F sensor 1 is able to indicate air fuel ratio by this
electrode layer of current. In addition, a heater is integrated in the
sensor to ensure the required operating temperature of about 800 °C
(1,472 °F).
On Board Diagnosis LogicINFOID:0000000005149156
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1
signal fluctuates according to fuel feedback control.
DTC Confirmation ProcedureINFOID:0000000005149157
Perform PROCEDURE FOR MALFUNCTION A first.
If the DTC cannot be confirmed, perform PROCEDURE FOR MALFUNCTION B.
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
PROCEDURE FOR MALFUNCTION A
1. Start engine and warm it up to normal operating temperature.
2. Let engine idle for 2 minutes.
3. Check 1st trip DTC.
4. If 1st trip DTC is detected, go to EC-138, "
Diagnosis Procedure".
PBIB3353E
PBIB3354E
DTC No. Trouble diagnosis name DTC detecting conditionPossible Cause
P0130
0130
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit A)
The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly in the range other
than approx. 2.2 V.
• Harness or connectors
(The A/F sensor 1 circuit is open
or shorted.)
• Air fuel ratio (A/F) sensor 1
P0150
0150
(Bank 2) B)
The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly approx. 2.2 V.
Revision: April 20092010 QX56
Page 1494 of 4210
![INFINITI QX56 2010 Factory Service Manual P0131, P0151 A/F SENSOR 1EC-141
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0131, P0151 A/F SENSOR 1
Component DescriptionINFOID:0000000005149160
The air fuel ratio (A/F) sensor INFINITI QX56 2010 Factory Service Manual P0131, P0151 A/F SENSOR 1EC-141
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0131, P0151 A/F SENSOR 1
Component DescriptionINFOID:0000000005149160
The air fuel ratio (A/F) sensor](/img/42/57032/w960_57032-1493.png)
P0131, P0151 A/F SENSOR 1EC-141
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0131, P0151 A/F SENSOR 1
Component DescriptionINFOID:0000000005149160
The air fuel ratio (A/F) sensor 1 is a planar one-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is composed an elec-
trode layer, which transports ions. It has a heater in the element.
The sensor is capable of precise m
easurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range.
The exhaust gas components diffuse through the diffusion layer at
the sensor cell. An electrode layer is applied voltage, and this current
relative oxygen density in lean. Also this current relative hydrocar-
bon density in rich.
Therefore, the A/F sensor 1 is able to indicate air fuel ratio by this
electrode layer of current. In addition, a heater is integrated in the
sensor to ensure the required operating temperature of about 800 °C
(1,472 °F).
On Board Diagnosis LogicINFOID:0000000005149161
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1
signal is not inordinately low.
DTC Confirmation ProcedureINFOID:0000000005149162
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5 V at idle.
WITH CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Select “A/F SEN1 (B1)” or “A/F SEN1 (B2)” in “DATA MONITOR” mode with CONSULT-III.
3. Check “A/F SEN1 (B1)” or “A/F SEN1 (B2)” indication.
If the indication is constantly approx. 0 V, go to EC-142, "
Diagnosis Procedure".
If the indication is not constantly approx. 0 V, go to next step.
4. Turn ignition switch OFF, wait at least 10 seconds and then restart engine.
5. Drive and accelerate vehicle to more than 40 km/h (25 MPH) within 20 seconds after restarting engine.
PBIB3353E
PBIB3354E
DTC No. Trouble diagnosis name DTC detecting conditionPossible Cause
P0131
0131
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit low voltage • The A/F signal computed by ECM from the A/
F sensor 1 signal is constantly approx. 0V. • Harness or connectors
(The A/F sensor 1 circuit is open or
shorted.)
• Air fuel ratio (A/F) sensor 1
P0151
0151
(Bank 2)
Revision: April 20092010 QX56
Page 1495 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-142
< COMPONENT DIAGNOSIS >[VK56DE]
P0131, P0151 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible durin INFINITI QX56 2010 Factory Service Manual EC-142
< COMPONENT DIAGNOSIS >[VK56DE]
P0131, P0151 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible durin](/img/42/57032/w960_57032-1494.png)
EC-142
< COMPONENT DIAGNOSIS >[VK56DE]
P0131, P0151 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible during the cruising.
• If this procedure is not completed within 1 minute af ter restarting engine at step 4, return to step
4.
7. Check 1st trip DTC.
8. If 1st trip DTC is displayed, go to EC-142, "
Diagnosis Procedure".
WITH GST
Follow the procedure “WITH CONSULT-III” above.
Diagnosis ProcedureINFOID:0000000005149163
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-85, "
Ground Inspection".
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2.CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect A/F sensor 1 harness connector.
2. Turn ignition switch ON.
ENG SPEED 1,000 - 3,200 rpm
VHCL SPEED SE More than 40 km/h (25 MPH)
B/FUEL SCHDL 1.5 - 9.0 msec
Gear position Suitable position
BBIA0354E
BBIA0376E
Revision: April 20092010 QX56
Page 1498 of 4210
![INFINITI QX56 2010 Factory Service Manual P0132, P0152 A/F SENSOR 1EC-145
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0132, P0152 A/F SENSOR 1
Component DescriptionINFOID:0000000005149164
The air fuel ratio (A/F) sensor INFINITI QX56 2010 Factory Service Manual P0132, P0152 A/F SENSOR 1EC-145
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0132, P0152 A/F SENSOR 1
Component DescriptionINFOID:0000000005149164
The air fuel ratio (A/F) sensor](/img/42/57032/w960_57032-1497.png)
P0132, P0152 A/F SENSOR 1EC-145
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0132, P0152 A/F SENSOR 1
Component DescriptionINFOID:0000000005149164
The air fuel ratio (A/F) sensor 1 is a planar one-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is composed an elec-
trode layer, which transports ions. It has a heater in the element.
The sensor is capable of precise m
easurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range.
The exhaust gas components diffuse through the diffusion layer at
the sensor cell. An electrode layer is applied voltage, and this current
relative oxygen density in lean. Also this current relative hydrocar-
bon density in rich.
Therefore, the A/F sensor 1 is able to indicate air fuel ratio by this
electrode layer of current. In addition, a heater is integrated in the
sensor to ensure the required operating temperature of about 800 °C
(1,472 °F).
On Board Diagnosis LogicINFOID:0000000005149165
To judge the malfunction, the diagnosis checks that the A/F signal computed by ECM from the A/F sensor 1
signal is not inordinately high.
DTC Confirmation ProcedureINFOID:0000000005149166
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 10.5 V at idle.
WITH CONSULT-III
1. Start engine and warm it up to normal operating temperature.
2. Select “A/F SEN1 (B1)” or “A/F SEN1 (B2)” in “DATA MONITOR” mode with CONSULT-III.
3. Check “A/F SEN1 (B1)” or “A/F SEN1 (B2)” indication.
If the indication is constantly approx. 5 V, go to EC-146, "
Diagnosis Procedure".
If the indication is not constantly approx. 5 V, go to next step.
4. Turn ignition switch OFF, wait at least 10 seconds and then restart engine.
5. Drive and accelerate vehicle to more than 40 km/h (25 MPH) within 20 seconds after restarting engine.
PBIB3353E
PBIB3354E
DTC No. Trouble diagnosis name DTC detecting conditionPossible Cause
P0132
0132
(Bank 1) Air fuel ratio (A/F) sensor 1
circuit high voltage • The A/F signal computed by ECM from the A/F
sensor 1 signal is constantly approx. 5V. • Harness or connectors
(The A/F sensor 1 circuit is open or
shorted.)
• Air fuel ratio (A/F) sensor 1
P0132
0132
(Bank 2)
Revision: April 20092010 QX56
Page 1499 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-146
< COMPONENT DIAGNOSIS >[VK56DE]
P0132, P0152 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible durin INFINITI QX56 2010 Factory Service Manual EC-146
< COMPONENT DIAGNOSIS >[VK56DE]
P0132, P0152 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible durin](/img/42/57032/w960_57032-1498.png)
EC-146
< COMPONENT DIAGNOSIS >[VK56DE]
P0132, P0152 A/F SENSOR 1
6. Maintain the following conditions for about 20 consecutive seconds.
NOTE:
•Keep the accelerator pedal as steady as possible during the cruising.
• If this procedure is not completed within 1 minute af ter restarting engine at step 4, return to step
4.
7. Check 1st trip DTC.
8. If 1st trip DTC is displayed, go to EC-146, "
Diagnosis Procedure".
WITH GST
Follow the procedure “WITH CONSULT-III” above.
Diagnosis ProcedureINFOID:0000000005149167
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body. Refer to EC-85, "
Ground Inspection".
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
2.CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
1. Disconnect A/F sensor 1 harness connector.
2. Turn ignition switch ON.
ENG SPEED 1,000 - 3,200 rpm
VHCL SPEED SE More than 40 km/h (25 MPH)
B/FUEL SCHDL 1.5 - 9.0 msec
Gear position Suitable position
BBIA0354E
BBIA0376E
Revision: April 20092010 QX56
Page 1502 of 4210
![INFINITI QX56 2010 Factory Service Manual P0133, P0153 A/F SENSOR 1EC-149
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0133, P0153 A/F SENSOR 1
Component DescriptionINFOID:0000000005149168
The air fuel ratio (A/F) sensor INFINITI QX56 2010 Factory Service Manual P0133, P0153 A/F SENSOR 1EC-149
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0133, P0153 A/F SENSOR 1
Component DescriptionINFOID:0000000005149168
The air fuel ratio (A/F) sensor](/img/42/57032/w960_57032-1501.png)
P0133, P0153 A/F SENSOR 1EC-149
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0133, P0153 A/F SENSOR 1
Component DescriptionINFOID:0000000005149168
The air fuel ratio (A/F) sensor 1 is a planar one-cell limit current sen-
sor. The sensor element of the A/F sensor 1 is composed an elec-
trode layer, which transports ions. It has a heater in the element.
The sensor is capable of precise m
easurement = 1, but also in the
lean and rich range. Together with its control electronics, the sensor
outputs a clear, continuous signal throughout a wide range.
The exhaust gas components diffuse through the diffusion layer at
the sensor cell. An electrode layer is applied voltage, and this current
relative oxygen density in lean. Also this current relative hydrocar-
bon density in rich.
Therefore, the A/F sensor 1 is able to indicate air fuel ratio by this
electrode layer of current. In addition, a heater is integrated in the
sensor to ensure the required operating temperature of about 800 °C
(1,472 °F).
On Board Diagnosis LogicINFOID:0000000005149169
To judge the malfunction of A/F sensor 1, this diagnosis measures response time of the A/F signal computed
by ECM from the A/F sensor 1 signal. The time is compensated by engine operating (speed and load), fuel
feedback control constant, and the A/F sensor 1 tem perature index. Judgment is based on whether the com-
pensated time (the A/F signal cycling time index) is inordinately long or not.
DTC Confirmation ProcedureINFOID:0000000005149170
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is more than 11 V at idle.
WITH CONSULT-III
PBIB3353E
PBIB3354E
DTC No. Trouble diagnosis nameDTC detecting conditionPossible Cause
P0133
0133
(Bank 1)
Air fuel ratio (A/F) sensor 1
circuit slow response • The response of the A/F signal computed by
ECM from A/F sensor 1 signal takes more than
the specified time. • Harness or connectors
(The A/F sensor 1 circuit is open or
shorted.)
• A/F sensor 1
• A/F sensor 1 heater
• Fuel pressure
• Fuel injector
• Intake air leaks
• Exhaust gas leaks
•PCV
• Mass air flow sensor
P0153
0153
(Bank 2)
Revision: April 20092010 QX56
Page 1503 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-150
< COMPONENT DIAGNOSIS >[VK56DE]
P0133, P0153 A/F SENSOR 1
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engi INFINITI QX56 2010 Factory Service Manual EC-150
< COMPONENT DIAGNOSIS >[VK56DE]
P0133, P0153 A/F SENSOR 1
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engi](/img/42/57032/w960_57032-1502.png)
EC-150
< COMPONENT DIAGNOSIS >[VK56DE]
P0133, P0153 A/F SENSOR 1
1. Start engine and warm it up to normal operating temperature.
2. Turn ignition switch OFF and wait at least 10 seconds.
3. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1minute under no load.
4. Let engine idle for 1 minute.
5. Select “A/F SEN1(B1) P1278/P1279” (for DTC P
0133) or “A/F SEN1(B2) P1288/P1289” (for DTC P0153)
of “A/F SEN1” in “DTC WORK SUPPORT” mode with CONSULT-III.
6. Touch “START”. If “COMPLETED” appears on CONSULT-III screen, go to step 10.
If “COMPLETED” does not appear on CONSUL T-III screen, go to the following step.
7. After perform the following procedure, “TESTING” will be displayed on the CONSULT-III screen.
a. Increase the engine speed up to 4,000 to 5,000 rpm and keep it for 10 seconds.
b. Fully release accelerator pedal and then let engine idle for about 10 seconds. If “TESTING” is not displayed after 10 seconds, refer to EC-74
.
8. Wait for about 20 seconds at idle under the condition that “TESTING” is displayed on the CONSULT-III screen.
9. Make sure that “TESTING” changes to “COMPLETED”. If “TESTING” changed to “OUT OF CONDITION”, refer to EC-74
.
10. Make sure that “OK” is display ed after touching “SELF-DIAG RESULT”.
If “NG” is displayed, go to EC-150, "
Diagnosis Procedure".
WITH GST
1. Start engine and warm it up to normal operating temperature.
2. Select Service $01 with GST.
3. Calculate the total value of “Short term fuel trim” and “Long term fuel trim” indications.
Make sure that the total percentage should be within ±15 %.
If OK, go to the following step.
If NG, check the following.
• Intake air leaks
• Exhaust gas leaks
• Incorrect fuel pressure
• Lack of fuel
• Fuel injector
• Incorrect PCV hose connection
• PCV valve
• Mass air flow sensor
4. Turn ignition switch OFF and wait at least 10 seconds.
5. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1minute under no load.
6. Let engine idle for 1 minute.
7. Increase the engine speed up to 4,000 to 5,000 rpm and keep it for 10 seconds.
8. Fully release accelerator pedal and then let engine idle for about 1 minute.
9. Select Service $07 with GST. If the 1st trip DTC is displayed, go to EC-150, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000005149171
1.CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Revision: April 20092010 QX56
Page 1508 of 4210
![INFINITI QX56 2010 Factory Service Manual P0137, P0157 HO2S2EC-155
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0137, P0157 HO2S2
Component DescriptionINFOID:0000000005149172
The heated oxygen sensor 2, after three way ca INFINITI QX56 2010 Factory Service Manual P0137, P0157 HO2S2EC-155
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0137, P0157 HO2S2
Component DescriptionINFOID:0000000005149172
The heated oxygen sensor 2, after three way ca](/img/42/57032/w960_57032-1507.png)
P0137, P0157 HO2S2EC-155
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0137, P0157 HO2S2
Component DescriptionINFOID:0000000005149172
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is controlled to stoichiometric, by the sig-
nal from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
On Board Diagnosis LogicINFOID:0000000005149173
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the air fuel
ratio (A/F) sensor 1. The oxy-
gen storage capacity of the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the maximum voltage of the sensor
is sufficiently high during the various driving condition such as fuel-
cut.
DTC Confirmation ProcedureINFOID:0000000005149174
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
WITH CONSULT-III
TESTING CONDITION:
For better results, perform “DTC WORK SUPPORT” at a temperature of 0 to 30 °C (32 to 86 °F).
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
2. Start engine and warm it up to the normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C (158° F).
SEF327R
PBIB1154E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0137
0137
(Bank 1) Heated oxygen sensor 2
circuit low voltage The maximum voltage from the sensor is not
reached to the specified voltage. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
• Fuel pressure
• Fuel injector
• Intake air leaks
P0157
0157
(Bank 2)
Revision: April 20092010 QX56
Page 1513 of 4210
![INFINITI QX56 2010 Factory Service Manual EC-160
< COMPONENT DIAGNOSIS >[VK56DE]
P0138, P0158 HO2S2
P0138, P0158 HO2S2
Component DescriptionINFOID:0000000005149178
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the INFINITI QX56 2010 Factory Service Manual EC-160
< COMPONENT DIAGNOSIS >[VK56DE]
P0138, P0158 HO2S2
P0138, P0158 HO2S2
Component DescriptionINFOID:0000000005149178
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the](/img/42/57032/w960_57032-1512.png)
EC-160
< COMPONENT DIAGNOSIS >[VK56DE]
P0138, P0158 HO2S2
P0138, P0158 HO2S2
Component DescriptionINFOID:0000000005149178
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of
the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is cont rolled to stoichiometric, by the sig-
nal from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated ox ygen sensor 2 is not used for
engine control operation.
On Board Diagn osis LogicINFOID:0000000005149179
The heated oxygen sensor 2 has a much longer switching time between rich and lean than the air fuel ratio (A/
F) sensor 1. The oxygen storage capa city of the three way catalyst (manifold) causes the longer switching
time.
MALFUNCTION A
To judge the malfunctions of heated oxygen sensor 2, ECM monitors
whether the voltage is unusually high during the various driving con-
dition such as fuel-cut.
MALFUNCTION B
To judge the malfunctions of heated oxygen sensor 2, ECM monitors
whether the minimum voltage of sensor is sufficiently low during the
various driving condition such as fuel-cut.
DTC Confirmation ProcedureINFOID:0000000005149180
Perform PROCEDURE FOR MALFUNCTION A first.
SEF327R
PBIB1848E
PBIB2376E
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0138
0138
(Bank 1) Heated oxygen sensor 2
circuit high voltage A)
An excessively high voltage from the sen-
sor is sent to ECM. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
P0158
0158
(Bank 2) B)
The minimum voltage from the sensor is
not reached to the specified voltage. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
• Fuel pressure
• Fuel injector
Revision: April 20092010 QX56
Page 1520 of 4210
![INFINITI QX56 2010 Factory Service Manual P0139, P0159 HO2S2EC-167
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0139, P0159 HO2S2
Component DescriptionINFOID:0000000005149184
The heated oxygen sensor 2, after three way ca INFINITI QX56 2010 Factory Service Manual P0139, P0159 HO2S2EC-167
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0139, P0159 HO2S2
Component DescriptionINFOID:0000000005149184
The heated oxygen sensor 2, after three way ca](/img/42/57032/w960_57032-1519.png)
P0139, P0159 HO2S2EC-167
< COMPONENT DIAGNOSIS > [VK56DE]
C
D
E
F
G H
I
J
K L
M A
EC
NP
O
P0139, P0159 HO2S2
Component DescriptionINFOID:0000000005149184
The heated oxygen sensor 2, after three way catalyst (manifold),
monitors the oxygen level in the exhaust gas on each bank.
Even if switching characteristics of the air fuel ratio (A/F) sensor 1
are shifted, the air-fuel ratio is controlled to stoichiometric, by the sig-
nal from the heated oxygen sensor 2.
This sensor is made of ceramic zirconia. The zirconia generates volt-
age from approximately 1V in richer conditions to 0V in leaner condi-
tions.
Under normal conditions the heated oxygen sensor 2 is not used for
engine control operation.
On Board Diagnosis LogicINFOID:0000000005149185
The heated oxygen sensor 2 has a much longer switching time
between rich and lean than the air fuel
ratio (A/F) sensor 1. The oxy-
gen storage capacity of the three way catalyst (manifold) causes the
longer switching time. To judge the malfunctions of heated oxygen
sensor 2, ECM monitors whether the switching response of the sen-
sor's voltage is faster than specified during the various driving condi-
tion such as fuel-cut.
DTC Confirmation ProcedureINFOID:0000000005149186
NOTE:
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure
before conducting the next step.
1. Turn ignition switch OFF and wait at least 10 seconds.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds.
WITH CONSULT-III
TESTING CONDITION:
For better results, perform “DTC WORK SUPPORT” at a temperature of 0 to 30 °C (32 to 86 °F).
1. Turn ignition switch ON and select “DATA MONITOR” mode with CONSULT-III.
2. Start engine and warm it up to the normal operating temperature.
3. Turn ignition switch OFF and wait at least 10 seconds.
4. Start engine and keep the engine speed between 3,500 and 4,000 rpm for at least 1 minute under no load.
5. Let engine idle for 1 minute.
6. Make sure that “COOLAN TEMP/S” indicates more than 70 °C (158° F).
SEF327R
SEF302U
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0139
0139
(Bank 1) Heated oxygen sensor 2
circuit slow response It takes more time for the sensor to respond be-
tween rich and lean than the specified time. • Harness or connectors
(The sensor circuit is open or shorted)
• Heated oxygen sensor 2
• Fuel pressure
• Fuel injector
• Intake air leaks
P0159
0159
(Bank 2)
Revision: April 20092010 QX56