engine ISUZU AXIOM 2002 Service Owner's Guide

ISUZU AXIOM 2002 Service Owner's Guide AXIOM 2002 ISUZU ISUZU https://www.carmanualsonline.info/img/61/57174/w960_57174-0.png ISUZU AXIOM 2002 Service Owner's Guide

Page 129 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±103
Chart B: Failure on the Intake Control 
StepActionValue(s)Ye sNo
1Is the fuse No.F±7 normal?
ÐGo to Step 2
Replace the
fuse
2Is the relay No.

Page 131 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±105
Chart A: Does Not work At All 
StepActionValue(s)Ye sNo
11. Turn on the ignition switch (the engine is run).
2. Disconnect the mix actuator con

Page 132 of 2100

ISUZU AXIOM 2002  Service Owners Guide 1A±106
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Chart B: Mix Actuator Control Failure 
StepActionValue(s)Ye sNo
1Turn the ignition switch (the engine is run).
Dose the mix actuator fully stro

Page 134 of 2100

ISUZU AXIOM 2002  Service Owners Guide 1A±108
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Chart A: Does Not Work At All 
StepActionValue(s)Ye sNo
11. Turn on the ignition switch (the engine is run).
2. Disconnect the mode actuator co

Page 135 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±109
Chart B: Mode Actuator Control Failure 
StepActionValue(s)Ye sNo
1Turn on the ignition switch (the engine is run).
Dose the mode actuator fully

Page 137 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±111
ConditionPossible causeCorrection
The fan dose not rotate at allÐRefer to Chart A
The fan dose not rotate in the
MAX±HI modeÐRefer to Chart

Page 138 of 2100

ISUZU AXIOM 2002  Service Owners Guide 1A±112
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
Chart B: Fan Does Not Rotate in MAX HI Mode 
StepActionValue(s)Ye sNo
1Is the MAX-HI relay (C±35) normal?
ÐGo to Step 2
Replace the
relay
21.

Page 141 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±115
Inspection of the Magnetic Clutch System
6VE1 Engine
D08R200037

Page 142 of 2100

ISUZU AXIOM 2002  Service Owners Guide 1A±116
HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
ConditionPossible causeCorrection
Magnetic clutch does not workÐRefer to Chart A
Chart A: Magnetic Clutch Does Not work 
StepActionValue(s)Ye

Page 143 of 2100

ISUZU AXIOM 2002  Service Owners Guide HEATING, VENTILATION AND AIR CONDITIONING (HVAC)
1A±117
Chart A: Magnetic Clutch Does Not work  (Contd)
StepNo Ye s Value(s) Action
17Is the battery voltage applied between the harness side
connecto