FUEL EVAPORATIVE EMISSION CONTROL (EVAP) SYSTEM
DESCRIPTION
To reduce HC emission, evaporated fuel from the fuel tank is routed throug\
h the charcoal canister to the
intake manifold for combustion i

Page 2860 of 4087

LEXUS SC400 1991  Service Owners Manual 
3.  VISUALLY INSPECT FUEL TANK CAPCheck if the cap and/or gasket are deformed or damaged.
If necessary, repair or replace the cap.
INSPECTION OF CHARCOAL CANISTER
1.  REMOVE CHARCOAL CANISTER(a)  Dis

Page 2861 of 4087

LEXUS SC400 1991  Service Owners Manual 
4.  CLEAN FILTER IN CANISTERClean  the filter by blowing 294 kPa (3 kgf/cm2, 43 psi) of com-
pressed air into port A while holding port B closed.
NOTICE:
w Do not attempt to wash the canister.
w No a

Page 2862 of 4087

LEXUS SC400 1991  Service Owners Manual 
INSPECTION OF VSV
1.  DISCONNECT CABLE FROM NEGATIVE TERMINAL OFBATTERY
CAUTION: Work must be started after approx. 20 se-
conds or longer from the time the ignition switch is
turned to  the ºLOCKº

Page 2863 of 4087

LEXUS SC400 1991  Service Owners Manual 
4. INSPECT VSV
A. Inspect VSV for open circuitUsing an ohmmeter, check that there is continuity between
the terminals.
Resistance (Cold): 30±34  
If there is no continuity, replace the VSV.
B.  Ins

Page 2864 of 4087

LEXUS SC400 1991  Service Owners Manual 
(c)  Connect the following hoses:(1)  Vacuum hose (from vacuum pipe) to VSV
(2)  Vacuum hose (from charcoal canister) to VSV
(d)  Connect the VSV connector.
6.  REINSTALL INTAKE AIR CONNECTOR (a)  Co

Page 2865 of 4087

LEXUS SC400 1991  Service Owners Manual 
3. REINSTALL CHECK VALVEHINT: Reinstall the check valve with the black port facing the
charcoal canister side.
(a)  Install the grommet to the check valve.
(b)  Install the check valve to the hose en

Page 2881 of 4087

LEXUS SC400 1991  Service Owners Manual 
SERVICE SPECIFICATIONS
SERVICE DATA
VSVResistance30±34 
for EVAP
VSVResistance33±39 
for EGR
EGR valveResistance19.9±23.4  
(CALIF. only)
TORQUE SPECIFICATIONS
Part tightenedNVmkgf Vcmft Vlbf
V

Page 2897 of 4087

LEXUS SC400 1991  Service Owners Manual 
6.  REMOVE UPPER HIGH±TENSION CORD COVER(a)  Remove the two mounting bolts.
(b)  Disconnect  the front side claw groove of the cord coverfrom the claw of the lower cover, and remove the cord
cover.

Page 2900 of 4087

LEXUS SC400 1991  Service Owners Manual 
15. DISCONNECT HOSESDisconnect the following hoses:(1)  Water by±pass hose (from water inlet housing) from ISC valve
(2) Vacuum  hose (from PS air control valve) from air in-
take chamber
(3)  Vacuu