oil MITSUBISHI MONTERO 1998 Service Manual

MITSUBISHI MONTERO 1998 Service Manual MONTERO 1998 MITSUBISHI MITSUBISHI https://www.carmanualsonline.info/img/19/57333/w960_57333-0.png MITSUBISHI MONTERO 1998 Service Manual

Page 725 of 1501

MITSUBISHI MONTERO 1998  Service Manual          CLEARING DTCS
CAUTION:  When battery is disconnected, vehicle computer and memory
         systems may lose memory data. Driveability problems may
         exist until computer systems have c

Page 736 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 19:  Identifying HO2S Terminals (Front Or Rear)
Courtesy of Mitsubishi Motor Sales of America
Fig. 20:  Identifying IAC Motor Terminals
Courtesy of Mitsubishi Motor Sales of America
Fig. 21:  Ide

Page 737 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 22:  Identifying Ignition Coil Terminals (3000GT SOHC)
Courtesy of Mitsubishi Motor Sales of America

Page 738 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 23:  Identifying Ignition Coil Terminals (Montero)
Courtesy of Mitsubishi Motor Sales of America

Page 739 of 1501

MITSUBISHI MONTERO 1998  Service Manual Fig. 24:  Identifying Ignition Failure Sensor Terminals
Courtesy of Mitsubishi Motor Sales of America
Fig. 25:  Identifying Ignition Coil Terminals (Montero & 3000GT DOHC)
Courtesy of Mitsubishi Motor

Page 756 of 1501

MITSUBISHI MONTERO 1998  Service Manual          L - WIRING DIAGRAMS article.
         1) Specific self-diagnostic test is not available from
manufacturer at time of publication. Check ignition coil, power
transistor, spark plugs, fuel inje

Page 757 of 1501

MITSUBISHI MONTERO 1998  Service Manual          3) Connect an engine tachometer. Crank engine. Ensure
ignition coil primary current toggles on and off. Using scan tool,
read engine cranking speed (item 22). Compare tachometer and scan tool

Page 772 of 1501

MITSUBISHI MONTERO 1998  Service Manual          2) Disconnect pressure hose from oil pump. See Fig. 45.
Install Adapter (MB990993) on oil pump. Install Adapter (MB990994) o\
n
disconnected hose. Connect Pressure Gauge (MB990662) and shutof

Page 783 of 1501

MITSUBISHI MONTERO 1998  Service Manual See Fig. 1 . Connect negative voltmeter lead to ground.
         2) Disconnect generator output wire from terminal "B".
Install a 100-amp ammeter in series with terminal "B" and disconnected
output le

Page 785 of 1501

MITSUBISHI MONTERO 1998  Service Manual          1) Check continuity across rotor slip rings. Resistance
should be 3-5 ohms. Replace rotor if continuity is not present or
resistance is not within specification.
         2) Check continuity