MITSUBISHI MONTERO 1998  Service Manual �\
\
\
\
\
\
\
 
ABBREVIATION     DEFINITION

Page 27 of 1501

MITSUBISHI MONTERO 1998  Service Manual CO               Carbon Monoxide                                   

CO2              Carbon Dioxide                                    

CONV             Convertible

Page 30 of 1501

MITSUBISHI MONTERO 1998  Service Manual Ign.             Ignition                                          

In.              Inches                                            

Inj.             Injector

Page 87 of 1501

MITSUBISHI MONTERO 1998  Service Manual settings.
         2) Set blower/fan on high speed. Close doors and windows.
Insert thermometer in center vent. Operate system for 20 minutes to
allow system to stabilize. Measure temperature.

Page 102 of 1501

MITSUBISHI MONTERO 1998  Service Manual Transportation (DOT) approved, DOT 4BW or DOT 4BA refrigerant
containers.
         7) Never overfill refrigerant containers. The safe filling
level of a refrigerant container MUST NOT exceed 60 percen

Page 104 of 1501

MITSUBISHI MONTERO 1998  Service Manual          Other Means Of Identification
         Refrigerant R-134a, when viewed through a sight glass, may
have a "milky" appearance due to the mixture of refrigerant and
lubricating oil. As the refri

Page 141 of 1501

MITSUBISHI MONTERO 1998  Service Manual          than 0.5 volt or more than 4.5 volts, or an open or short
         circuit in "G" sensor system.
         1) Disconnect "G" sensor connector. Sensor is located on
bracket under center console

Page 235 of 1501

MITSUBISHI MONTERO 1998  Service Manual cavity and contact surfaces. Install oil seal using seal driver. Press
new oil seal into bearing case until it is flush with face of bearing
case. Install backing plate and bearing case.
         2) A

Page 276 of 1501

MITSUBISHI MONTERO 1998  Service Manual          ELECTRIC COOLING FAN
          COMPONENT TESTING
          Radiator Fan Motor (Diamante)
         1) Disconnect radiator fan motor connectors A39 and A40.
Ground fan motor connector A39 termi

Page 277 of 1501

MITSUBISHI MONTERO 1998  Service Manual motor connector terminal No. 2 (Black wire). Using a fused jumper
wire, connect battery voltage to fan motor connector terminal No. 1
(White/Black wire). See WIRING DIAGRAMS. Fan motor should operate