air condition NISSAN 350Z 2007 Z33 Roof Owner's Manual
[x] Cancel search | Manufacturer: NISSAN, Model Year: 2007, Model line: 350Z, Model: NISSAN 350Z 2007 Z33Pages: 130, PDF Size: 5.4 MB
Page 57 of 130

SOFT TOP
RF-57
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
4. CHECK SOFT TOP CONTROL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 22 and ground.
OK or NG
OK >> Replace soft top switch assembly 2.
NG >> Replace soft top control unit.
Check Body Interference Prevention Switch (Open Operate)NIS0006Y
1. CHECK BODY INTERFERENCE PREVENTION SWITCH
1. Start engine.
2. Operate soft top switch OPEN, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top switch assembly 1 is OK.
NG >> GO TO 2.
2. CHECK BODY INTERFERENCE PREVENTION SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and soft top switch assembly 1 (body interference prevention switch) con-
nector.
3. Check continuity between soft top control unit connector B67
terminal 32 and soft top switch assembly 1 connector B212 ter-
minal 2.
4. Check continuity between soft top control unit connector B67
terminal 32 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.22 (W/R) - Ground : Approx. 5V
PIIA7923E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 32 (W) Ground OP10 5 → 0
PIIA7926E
32 (W) - 2 (W) : Continuity should exist.
32 (W) - Ground : Continuity should not exist.
PIIA7927E
Page 58 of 130

RF-58
SOFT TOP
Revision: 2006 November2007 350Z
3. CHECK BODY INTERFERENCE PREVENTION SWITCH GROUND CIRCUIT
Check continuity between soft top switch assembly 1 connector B212 terminal 3 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK SOFT TOP CONTROL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 32 and ground.
OK or NG
OK >> Replace soft top switch assembly 1.
NG >> Replace soft top control unit.
Check Roof Full Open Detection Switch (Open Operate)NIS0006Z
1. CHECK ROOF FULL OPEN DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch OPEN, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top switch assembly 1 (roof full open detection
switch) is OK.
NG >> GO TO 2.3 (B) - Ground : Continuity should exist.
PIIA7928E
32 (W) - Ground : Approx. 5V
PIIA7926E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 21 (W/L) Ground OP10 → OP11 5 → 0
PIIA7929E
Page 59 of 130

SOFT TOP
RF-59
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK ROOF OPEN DETECTION SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and soft top switch assembly 1 connector.
3. Check continuity between soft top control unit connector B67
terminal 21 and soft top switch assembly 1 connector B212 ter-
minal 1.
4. Check continuity between soft top control unit connector B67
terminal 21 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK SOFT TOP CONTROL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 21 and ground.
OK or NG
OK >> Replace soft top switch assembly 1.
>> Replace soft top control unit.
Check Storage Lid Unlock Actuator (Close Operate)NIS00070
1. CHECK STORAGE LID UNLOCK ACTUATOR SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between storage lid unlock actuator connector and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.21 (W/L) - 1 (W/L) : Continuity should exist.
21 (W/L) - Ground : Continuity should not exist.
PIIA7930E
21 (W/L) - Ground : Approx. 5V
PIIA7929E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B65 (LH) 1 (R)
Ground CL1 → CL2 0 → Battery voltage → 0
B70 (RH) 1 (L)
PIIA7907E
Page 60 of 130

RF-60
SOFT TOP
Revision: 2006 November2007 350Z
2. CHECK STORAGE LID UNLOCK ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and storage lid unlock actuator connector.
3. Check continuity between soft top control unit connector B66
terminal 15 and storage lid unlock actuator connector B65 (LH),
B70 (RH) terminal 1.
4. Check continuity between soft top control unit connector B66
terminal 15 and ground.
OK or NG
OK >> Replace soft top control unit.
NG >> Repair or replace harness.
3. CHECK STORAGE LID UNLOCK ACTUATOR GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect storage lid unlock actuator connector.
3. Check continuity between storage lid unlock actuator connector
B65 (LH), B70 (RH) terminal 2 and ground.
OK or NG
OK >> Replace malfunction storage lid unlock actuator (LH or
RH).
NG >> Repair or replace harness.
Check Storage Lid Full Close Detection Switch (Close Operate)NIS00071
1. CHECK STORAGE LID FULL CLOSE DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Storage lid switch (LH & RH) (CLOSE) is OK.
NG >> GO TO 2.B65 (LH) 15 (OR) - 1 (R) : Continuity should exist.
B70 (RH) 15 (OR) - 1 (L) : Continuity should exist.
15 (OR) - Ground : Continuity should not exist.
PIIA7908E
B65 (LH) 2 (B) - Ground : Continuity should exist.
B70 (RH) 2 (B/Y) - Ground : Continuity should exist.
PIIA7909E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B6724 (G) for
switch RH
GroundCL1
5 → 0
25 (L/Y) for
switch LHCL1 → CL2
PIIA7910E
Page 63 of 130

SOFT TOP
RF-63
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK STORAGE LID ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and storage lid actuator connector.
3. Check the following.
–Continuity between soft top control unit connector B68 terminal
41, 48 and storage lid actuator (LH) connector T28 terminal 1, 2.
–Continuity between soft top control unit connector B68 terminal
41, 48 and ground.
4. Check the following.
–Continuity between soft top control unit connector B66 terminal
5, 13 and storage lid actuator (RH) connector T30 terminal 1, 2.
–Continuity between soft top control unit connector B66 terminal
5, 13 and ground.
OK or NG
OK >> Replace soft top control unit.
NG >> Repair or replace harness.
Check Storage Lid Full Open Detection Switch (Close Operate)NIS00073
1. CHECK STORAGE LID FULL OPEN DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Storage lid switch (OPEN) (storage lid full open detec-
tion switch) is OK.
NG >> GO TO 2.41 (R/L) - 2 (R/L) : Continuity should exist.
48 (Y/B) - 1 (Y/B) : Continuity should exist.
41 (R/L) - Ground : Continuity should not exist.
48 (Y/B) - Ground : Continuity should not exist.
5 (R/B) - 1 (R/B) : Continuity should exist.
13 (L/R) - 2 (L/R) : Continuity should exist.
5 (R/B) - Ground : Continuity should not exist.
13 (L/R) - Ground : Continuity should not exist.
PIIA7915E
PIIA7916E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 33 (BR) Ground CL2 → CL3 5 → 0
PIIA7917E
Page 65 of 130

SOFT TOP
RF-65
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
Check Body Interference Prevention Switch (Close Operate)NIS00074
1. CHECK BODY INTERFERENCE PREVENTION SWITCH
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top switch assembly 1 (body interference preven-
tion switch) is OK.
NG >> GO TO 2.
2. CHECK BODY INTERFERENCE PREVENTION SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and soft top switch assembly 1 (body interference prevention switch) con-
nector.
3. Check continuity between soft top control unit connector B67
terminal 32 and soft top switch assembly 1 connector B212 ter-
minal 2.
4. Check continuity between soft top control unit connector B67
terminal 32 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK BODY INTERFERENCE PREVENTION SWITCH GROUND CIRCUIT
Check continuity between soft top switch assembly 1 connector B212 terminal 3 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 32 (W) Ground CL3 0 → 5
PIIA7926E
32 (W) - 2 (W) : Continuity should exist.
32 (W) - Ground : Continuity should not exist.
PIIA7927E
3 (B) - Ground : Continuity should exist.
PIIA7928E
Page 67 of 130

SOFT TOP
RF-67
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
2. CHECK ROOF ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit connector.
3. Check the following.
–Continuity between soft top control unit connector B68 terminal
37, 42 and roof actuator (LH) connector B59 terminal 1, 2.
–Continuity between soft top control unit connector B68 terminal
37, 42 and ground.
4. Check the following.
–Continuity between soft top control unit connector B66 terminal
3, 10 and roof actuator (RH) connector B72 terminal 1, 2.
–Continuity between soft top control unit connector B66 terminal
3, 10 and ground.
OK or NG
OK >> Replace soft top control unit.
NG >> Repair or replace harness.
Check Roof Full Close Detection SwitchNIS00076
1. CHECK ROOF FULL CLOSE DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top switch assembly 2 (roof full close detection
switch) is OK.
NG >> GO TO 2.37 (R) - 2 (R) : Continuity should exist.
42 (Y) - 1 (Y) : Continuity should exist.
37 (R) - Ground : Continuity should not exist.
42 (Y) - Ground : Continuity should not exist.
PIIA7921E
3 (R) - 1 (R) : Continuity should exist.
10 (Y) - 2 (Y) : Continuity should exist.
3 (R) - Ground : Continuity should not exist.
10 (Y) - Ground : Continuity should not exist.
PIIA7922E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 20 (W/B) Ground CL5 → CL6 0 → 5
PIIA7931E
Page 69 of 130

SOFT TOP
RF-69
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
Check 5th Bow Actuator (Close Operate)NIS00077
1. CHECK 5TH BOW ACTUATOR INPUT SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between 5th bow actuator connector and ground.
OK or NG
OK >> Replace 5th bow actuator.
NG >> GO TO 2.
2. CHECK 5TH BOW ACTUATOR CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and 5th bow actuator connector.
3. Check continuity between soft top control unit connector B68
terminal 44, 45 and 5ht bow actuator connector B233 terminal 1,
2.
4. Check continuity between soft top control unit connector B68
terminal 44, 45 and ground.
OK or NG
OK >> Replace soft top control unit.
NG >> Repair or replace harness.
Check 5th Bow Full Close Detection Switch (Close Operate)NIS00078
1. CHECK 5TH BOW FULL CLOSE DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Plate rail RR (5th bow full close switch) is OK.
NG >> GO TO 2.
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B233 1 (G/Y) Ground CL4 → CL5 0 → Battery voltage → 0
PIIB9114E
44 (G/R) - 1 (G/Y) : Continuity should exist.
45 (G/Y) - 2 (G/R) : Continuity should exist.
44 (G/R) - Ground : Continuity should not exist.
45 (G/Y) - Ground : Continuity should not exist.
PIIA7901E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 27 (GY) Ground CL5 → CL6 0 → 5 → 0
PIIA7902E
Page 71 of 130

SOFT TOP
RF-71
C
D
E
F
G
H
J
K
L
MA
B
RF
Revision: 2006 November2007 350Z
Check 5th Bow Full Open Detection Switch (Close Operate)NIS00079
1. CHECK 5TH BOW FULL OPEN DETECTION SWITCH SIGNAL
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Plate rail RR (5th bow full open switch) is OK.
NG >> GO TO 2.
2. CHECK 5TH BOW FULL OPEN DETECTION SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and 5th bow switch assembly connector.
3. Check continuity between soft top control unit connector B67
terminal 26 and 5th bow switch assembly connector B214 termi-
nal 1.
4. Check continuity between soft top control unit connector B67
terminal 26 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK 5TH BOW FULL OPEN DETECTION SWITCH GROUND CIRCUIT
Check continuity between 5th bow switch assembly connector B214 terminal 3 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 26 (LG) Ground CL6 → CL7 5 → 0
PIIA7905E
26 (LG) - 1 (LG) : Continuity should exist.
26 (LG) - Ground : Continuity should not exist.
PIIA7906E
3 (B) - Ground : Continuity should exist.
PIIA7904E
Page 72 of 130

RF-72
SOFT TOP
Revision: 2006 November2007 350Z
4. CHECK SOFT TOP CONTORL UNIT OUTPUT SIGNAL
1. Connect soft top control unit connector.
2. Start engine.
3. Check voltage between soft top control unit connector B67 ter-
minal 26 and ground.
OK or NG
OK >> Replace plate rail RR.
NG >> Replace soft top control unit.
Check 5th Bow Half-Latch Switch (Close Operate)NIS0007A
1. CHECK 5TH BOW HALF-LATCH SWITCH SIGNAL CHECK
1. Start engine.
2. Operate soft top switch CLOSE, check voltage between soft top control unit connector and ground.
OK or NG
OK >> Soft top lock switch (5th bow half-latch switch) is OK.
NG >> GO TO 2.
2. CHECK 5TH BOW HALF-LATCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect soft top control unit and soft top lock switch (at 5th bow lock assembly in storage lid) connec-
tor.
3. Check continuity between soft top control unit connector B67
terminal 31 and soft top lock switch connector T205 terminal 5.
4. Check continuity between soft top control unit connector B67
terminal 31 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.26 (LG) - Ground : Approx. 5V
PIIA7905E
ConnectorTerminal (Wire color)
Roof conditionVoltage (V)
(Approx.)
(+) (-)
B67 31 (L) Ground CL9 → CL10 0 → 5
PIIA7897E
31 (L) - 5 (L) : Continuity should exist.
31 (L) - Ground : Continuity should not exist.
PIIA7898E