diagnostic menu RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Climate Control Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 60
Page 10 of 60
62B - 10
CLIMATE CONTROL
Fault finding – Configurations and programming62B
V3 MR-372-J84-62B000$040.mif
Vdiag No.: 44
CLIMATE CONTROL
Fault finding – Configurations and programming
CLIMATE CONTROL COMPUTER CONFIGURATION:
The climate control computer has 2 configuration functions. These configurations need to be set after the computer
has been replaced.
These two configurations are important as they ensure air conditioning is optimised within the vehicle (better control
of automatic climate control). If they are not correctly entered, cold air and warm air production will be severely
affected (e.g. heating resistors will not be switched on to heat the passenger compartment air).
These configurations can be accessed in repair mode by the diagnostic tool and can only be entered using
the fault finding by computer menu as opposed to the fault finding by function menu.
These configurations can be read, also using the diagnostic tool in repair mode to ensure they have been correctly
set. Configurations can be read in both fault finding by computer mode and fault finding by function mode.
–The first configuration is CF044 Vehicle type; this configuration allows you to enter the body type to which the
climate control computer is fitted (J84/R84 for 4 wheel drive Mégane Scénic and Scénic, and OTHER X84 for all
other Méganes). The configuration reading is called: LC013 Vehicle type.
–The second configuration is CF117 Type of heating resistors; this configuration is used to enter the type of
passenger compartment air heating resistors fitted in the vehicle. There are three options: WITHOUT for vehicles
without 1000 W and 1800 W resistors.
Heating resistors are mainly fitted on vehicles with Diesel engines.
They are located in the ventilation - air distribution unit (left-hand side), next to the heater matrix. The label affixed
to the resistor unit (with the part number) specifies whether the resistors are 1000 or 1800 W (Note: 1800 W
resistors are mainly fitted to Mégane Scénics). This configuration reading is called: LC043 Heating resistor.
Note:
In fault finding by function mode, the diagnostic tool can also display the configuration readings of the other computers
involved in the air conditioning function. All configurations of the air conditioning function (injection computer, UCH
and Protection and Switching Unit) are listed in Section 62A Air conditioning.
MIXING
AND DISTRIBUTION MOTOR PROGRAMMING PROCEDURE (self-setting):
There is no specific programming operation for the mixing motor and the distribution motor.
However, the minimum and maximum limits of these motors have to be programmed. This operation is automatic and
is performed in the following cases:
–after replacing the mixing or distribution motor,
–after disconnecting the battery or after disconnecting the climate control computer supply fuse,
–if a fault, declared as present when the ignition was switched off, disappears the next time the ignition is switched
on.
IMPORTANT
To ensure this programming operation is performed correctly, the passenger compartment blower must be
switched off (speed set to 0).
ACREG X84 1.1
Edition 2
MR-372-J84-62B000$040.mif