ABS RENAULT SCENIC 2009 J84 / 2.G Air Conditioning Manual Conditioning Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 23
Page 14 of 23
MANUAL AIR CONDITIONING
Fault finding – Fault Finding Chart62C
62C-14V2 MR-372-J84-62C000$040.mif
ALP 3
CONTINUED
Check that there is a + 12 V accessories supply on track B1 of the resistor unit and an earth on track A1 of the
control panel connector.
Repair if necessary.
Make sure that the control panel speed selection button works properly.
Repair if necessary.
Make sure the resistor unit functions properly.
Replace the resistor unit if the resistances of the first three speeds are not:
Speed 1 (tracks A1 and A4): 1.97 ΩΩ Ω Ω
Speed 2 (tracks A2 and A4): 1.3 ΩΩ Ω Ω
Speed 3 (tracks A3 and A4): 0.41 ΩΩ Ω Ω
Check the insulation, continuity and absence of interference resistance of the connections:
Control panel track A2 Track A1 of the resistor unit
Control panel track A3 Track A2 of the resistor unit
Control panel track A4 Track A3 of the resistor unit
Control panel track A5 Track A4 of the resistor unit
Repair if necessary.
Check the insulation, continuity and absence of interference resistance of the connections:
Fan assembly track 2 Track A4 of the resistor unit
Repair if necessary.
Make sure the fan blade is in good condition and not wobbling on its axle.
Repair if necessary.
End of fault finding procedure.
AFTER REPAIRCheck that the system is operating correctly.
Page 18 of 23
MANUAL AIR CONDITIONING
Fault finding – Fault Finding Chart62C
62C-18V2 MR-372-J84-62C000$040.mif
ALP 5
CONTINUED
Make sure that the control panel speed selection button works properly.
If necessary, recondition or replace the control panel.
Make sure the resistor unit functions properly.
Replace the resistor unit if the resistances of the first three speeds are not:
Speed 1 (tracks A1 and A4): 1.97 ΩΩ Ω Ω
Speed 2 (tracks A2 and A4): 1.3 ΩΩ Ω Ω
Speed 3 (tracks A3 and A4): 0.41 ΩΩ Ω Ω
Check the insulation, continuity and absence of interference resistance of the connections:
Control panel track A2 Track A1 of the resistor unit
Control panel track A3 Track A2 of the resistor unit
Control panel track A4 Track A3 of the resistor unit
Control panel track A5 Track A4 of the resistor unit
Repair if necessary.
Check the insulation, continuity and absence of interference resistance of the connections:
Fan assembly track 2 Track A4 of the resistor unit
Repair if necessary.
Make sure the fan blade is in good condition and not wobbling on its axle.
Repair if necessary.
Disconnect the black 2-track connector of the engine cooling fan and check the resistance of the motor
between tracks 1 and 2.
Replace the engine cooling fan if the resistance is not between 0.2 Ω and 0.5 Ω.
End of fault finding procedure.
AFTER REPAIRCheck that the system is operating correctly.