ignition RENAULT SCENIC 2009 J84 / 2.G Engine And Peripherals EDC16 Service Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: SCENIC, Model: RENAULT SCENIC 2009 J84 / 2.GPages: 273
Page 119 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B-119V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Interpretation of faults
DF276
PRESENT
INJECTOR CODE PROGRAMMING
1.DEF : Internal electronic fault when writing
2.DEF : No code in memory
NOTESCondition for applying fault finding ONLY to a present fault:
The fault is declared present after:
–reprogramming the injection computer,
–replacing and programming the injection computer.
Special notes:
If the fault is present:
–the engine speed is limited,
–the level 1 warning light is lit.
1.DEF
NOTESNone.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting for 1 minute and then re-establish dialogue,
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF276P
Page 120 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -120V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF276
CONTINUED
2.DEF
NOTESThis fault appears on any blank computer (new or recently
reprogrammed).
WARNING
A computer without the IMA option can be replaced by a computer with this option. The codes are not
saved during command SC003 Save computer data.
In this case, status ET104 Use of Injector Codes becomes YES, fault DF276 Injector Code Programming
will be present, and the engine will operate in defect mode.
Program the injector codes using command SC002 Enter injector codes.
Carry out the procedure described in the Interpretation of commands section.
If the fault is still present after switching off the ignition, waiting 1 minute and then re-establish dialogue:
Follow the interpretation of command SC002 Entering injector codes.
If the fault is still present, contact the Techline.
Otherwise clear the fault memory using RZ007 Fault memory.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
Page 121 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -121V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF532
PRESENT
OR
STOREDALTERNATOR CHARGE SIGNAL
CO.0 : Open circuit or short circuit to earth
CC.1 : Short circuit to + 12 V
1.DEF : Above maximum threshold
2.DEF : Below minimum threshold
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present when the ignition is switched on or with the engine
running.
Special notes:
If the fault is present, the level 1 warning light comes on.
IMPORTANT
The fault can appear after the alternator has been saturated for too long.
For stored faults, clear the fault, switch off the ignition and wait for 1 minute before
carrying out a road test to confirm the fault before any operation.
Run a multiplex network test (see 88B, Multiplexing).
If the fault is still present, check the insulation and continuity on the following connection:
Injection computer, connector C, track A3Alternator, Track 2, black connector
Repair if necessary.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF532
Page 123 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -123V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF619
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 125 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -125V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF620
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 126 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -126V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF621
PRESENT
OR
STOREDEGR VALVE JAMMED OPEN (OBD FAULT)
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after a road test.
Priorities when dealing with a number of faults:
–DF118 EGR solenoid valve servo-control,
–DF209 EGR valve position sensor circuit,
–DF272 EGR valve control circuit,
if they are present or stored.
Special note:
If the fault is present:
–there is heavy smoke coming from the exhaust,
–the OBD warning light will come on after three consecutive driving cycles (starting
+ 5 seconds + switching off the ignition and waiting 1 minute).
Use bornier Ele. 1681 or Ele. 1590 for any operation on the injection computer
connectors.
IMPORTANT
If the EGR valve needs to be replaced to resolve the fault, use command SC036
Reinitialise programming and select EGR valve to reinitialise the EGR valve offsets
(see Replacement of components).
Check the EGR valve connections.
Check the injection computer connections.
Repair if necessary.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF621
Page 127 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -127V3 MR-372-J84-13B250$450.mif
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF621
CONTINUED
Check the operation of the EGR valve:
–exit fault finding mode in CLIP,
–switch off the vehicle ignition,
–disconnect the EGR valve connector,
–remove the EGR valve.
–Check that there are no particles blocking the movement of the piston.
–Clean the EGR valve, (see Technical Note 3916A Cleaning the EGR valve).
–Refit the EGR valve, run command SC036 Reinitialise programming and select EGR valve to reinitialise the
EGR valve offsets (see Replacement of components).
If the valve is jammed or irrevocably seized, replace the EGR valve. Run command SC036 Reinitialise
programming and select EGR valve to reinitialise the EGR valve offsets (see Replacement of components).
Page 128 of 273

DIESEL INJECTION
Fault finding – Interpretation of faults13B
13B -128V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM No.: C1
Vdiag No.: 51
DF652
PRESENT
OR
STOREDTURBINE UPSTREAM TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present:
–ignition is on (CC.0),
–following a road test, engine warm (CO.1).
Special notes:
If the fault is present:
–the EGR function is inhibited,
–particle filter regeneration is inhibited,
–the vehicle performance is reduced,
–the level 1 warning light is illuminated.
Priorities when dealing with a number of faults:
DF011 Sensor voltage supply no. 1
IMPORTANT
The turbine upstream temperature sensor only measures temperatures above
200˚C.
Check the condition of the turbine upstream temperature sensor connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 1589).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II, Scénic II, component code 120).
If one of the connectors is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
AFTER REPAIRDeal with any faults.
Carry out a road test followed by another check with the diagnostic tool.
EDC16_V51_DF652
Page 133 of 273

DIESEL INJECTION
Fault finding – Conformity check13B
13B - 133V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51DIESEL INJECTION
Fault finding – Conformity check
MAIN COMPUTER STATUSES AND PARAMETERS
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test conditions: ENGINE OFF, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
1Vehicle impactET077:Impact
detectedNOIn the event of a fault, refer
to the interpretation of
fault DF069 Impact
detected signal.
2Power supplyET001:Computer
+ after ignition
feedPRESENTIn the event of a fault, refer
to the interpretation of
DF015 Main relay
control circuit.
PR071:Computer
feed voltage9 V < X < 16 VIn the event of a fault,
carry out a fault finding
procedure on the charging
circuit and refer to the
interpretation for DF047
Computer supply
voltage.
PR358:Sensor
reference
voltage3.4 V < X <3.8 VNone
3SpeedPR190:Engine idle
speed
setpoint.Indicates the engine's
rotational speed setpoint
in rpm.In the event of a fault, refer
to the interpretation for
fault DF005 Engine
speed sensor circuit.
PR055:Engine speedGives the engine's rotational
speed in rpm.
With the ignition on
at 0 rpm
4Speed signalPR089:Vehicle
speedGives the vehicle speed in
mph. This parameter is
transmitted by the ABS
computer. This signal is
transmitted to the injection
on the multiplex network.In the event of a fault, test
the multiplex network.
(See 88B, Multiplexing).
EDC16_V51_CCONF
MR-372-J84-13B250$450.mif
Page 134 of 273

DIESEL INJECTION
Fault finding – Conformity check13B
13B - 134V3 MR-372-J84-13B250$450.mif
EDC16
PROGRAM NO.: C1
Vdiag No.: 51
MAIN COMPUTER STATUSES AND PARAMETERS (CONTINUED)
NOTESOnly check conformity after a complete check using the diagnostic tool. The values
shown in this conformity check are given as a guide.
Test conditions: ENGINE OFF, IGNITION ON.
Order FunctionParameter or Status
checked or ActionDisplay and Notes Fault finding
5Injection
configurationET104:Injector code useYESThis status indicates that
the IMA function is
activated. In the event of a
fault, consult the
interpretation of DF276
Injector code
programming.
6PressurePR035:Atmospheric
pressureIndicates the
atmospheric pressure
in mbar.
The sensor is built
into the computer.
Default value:
750 mbar.In the event of a fault,
consult the interpretation
of DF003 Atmospheric
pressure sensor circuit.
PR038:Rail pressure0 < X < 30 barIn the event of a fault,
consult the interpretation
of fault DF007 Rail
pressure sensor circuit.
7
TemperaturePR059:Inlet air
temperatureShows the inlet air
temperature
Ignition on PR061 =
PR059
Default value: 20 ˚CIn the event of a fault, refer
to the interpretation for
DF039 Inlet air
temperature circuit
sensor
8PR064:Coolant
temperatureShows the engine
coolant temperature
in ˚C
Default value: 119 ˚CIn the event of a fault, refer
to the interpretation of
DF001 Coolant
temperature sensor
circuit.
9TorquePR015:Engine torqueThis parameter is only
valid when the engine has
been started.
10Charging circuitPR016:Alternator flow0 mAIn the event of a fault,
check the charging circuit.