Diagram RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals EDC16C36 Owner's Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 431, PDF Size: 2.03 MB
Page 76 of 431

13B-76V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF033
PRESENT
OR
STOREDTHERMOPLUNGER 2 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC064 Thermoplunger no. 2 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF033/EDC16C36_V58_DF033
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
Page 78 of 431

13B-78V9 MR-372-J84-13B450$101.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF034
PRESENT
OR
STOREDTHERMOPLUNGER 3 RELAY CONTROL CIRCUIT
CC.1: Short circuit to + 12 V
1.DEF: Internal electronic fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after:
– the ignition is switched on,
– with the engine running,
– actuator command AC031 Thermoplunger no. 3 relay.
Special notes:
Use bornier Elé. 1681 for all operations on the connectors of the engine management
computer.
Use the Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
CC.1
NOTESNone.
1.DEFSpecial note:
This fault appears when the computer control section has
overheated.
Check the conformity of fuses F2 (70A) and F3 (70A) on component 777, replace if necessary.
Check the connections on the additional heater interface unit.
check the engine management computer connections.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check for + 12 V after ignition feed on connections BP27 and BP35 of component 1550.
If there is no + 12 V, refer to the interpretation of fault DF151 Main relay circuit.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
EDC16C36_V48_DF034/EDC16C36_V58_DF034EDC16 C36
Program No.: 91
Vdiag No.: 48, 58
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
Page 80 of 431

13B-80V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF038
PRESENT
OR
STOREDCOMPUTER
1.DEF: Internal electronic fault
2.DEF: Voltage too low
3.DEF: Data inconsistency
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– starting the engine,
– a road test.
Special notes:
If the fault is present:
– depending on the situation, the level 1 or level 2 warning light is lit for 1.DEF,
–the level 1 warning light comes on for 3.DEF,
–the level 2 warning light comes on for 2.DEF,
– increase in polluting emissions,
– injection cut-off in defect mode,
– the engine stops.
Use bornier Elé. 1681 for all operations on the engine management computer
connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
If the fault is stored, clear the fault from the computer memory.
Switch off the ignition, wait for the end of the power latch, then switch the ignition back on. Start the engine and re-
establish dialogue.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF038/EDC16C36_V4C_DF038/EDC16C36_V48_DF038/EDC16C36_V50_DF038/EDC16C36_V54_DF038/
EDC16C36_V58_DF038
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 82 of 431

13B-82V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF046
PRESENT
OR
STOREDBATTERY VOLTAGE
1.DEF: Above max threshold
2.DEF: Below minimum threshold
3.DEF: Initialisation not done.
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– starting the engine,
– a road test.
Special notes:
– thermoplungers cut-off,
– engine torque limited,
Computer operating voltage: 6 V < operating voltage < 16.5 V.
It is then not possible to start the engine.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESNone.
Check the charging circuit, apply Technical Note 6014A Checking the charging circuit.
Carry out the necessary repairs.
EDC16C36_V44_DF046/EDC16C36_V4C_DF046/EDC16C36_V48_DF046/EDC16C36_V50_DF046/EDC16C36_V54_DF046/
EDC16C36_V58_DF046
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 83 of 431

13B-83V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF046
CONTINUED
2.DEFNOTESUse the Wiring Diagram Technical Notes for the vehicle.
Reminder of computer operating voltage: 6 V < operating voltage < 16.5 V
Using a voltmeter, take a reading of the battery voltage at its terminals.
– Compare the voltage obtained with the value displayed on the diagnostic tool PR074 Battery voltage.
If it there is no difference (less than 1 V):
Recharge and test the battery and replace it if it is defective.
Next check the charge circuit.
If there is a difference (greater than 1 V):
– Check the tightness and the condition of the battery terminals.
– Using the appropriate wiring diagram:
Check the continuity and absence of interference resistance on the following connections:
– Connection code 3FB between components 597 and 120.
– Connection code AP29 between components 597 and 120.
– Connection code NT between components NT and 120.
(Check the four NT connections)
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
3.DEF
NOTESOnly deal with this fault when it is present.
Switch off the ignition and wait for the diagnostic tool message (maximum time 8minutes) Communication lost
with computer: EDC16 C36, check the tool connection and computer power supply before switching the
ignition back on.
Switch on the ignition again and check if the fault is still present.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 84 of 431

13B-84V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF047
PRESENT
OR
STOREDCOMPUTER SUPPLY VOLTAGE
1.DEF: Voltage outside permitted range of values
NOTESConditions for applying the fault finding procedure to a stored fault:
– The fault is declared after the ignition has been switched on
Special notes:
– impossible to start the engine.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
1.DEF
NOTESImpossible to start.
Check the continuity and absence of interference resistance on the following connection:
– Connection code AP29 between components 597 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
Check the condition of the injection control unit supply relay (R08) in the engine fuse and relay box (no bad
contacts or oxidation on the relay mounting clips).
If there is a repair procedure (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair) repair the wiring, otherwise replace it.
If the fault does not recur, start the engine and wait 1 min.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, contact the Techline.
EDC16C36_V44_DF047/EDC16C36_V4C_DF047/EDC16C36_V48_DF047/EDC16C36_V50_DF047/EDC16C36_V54_DF047/
EDC16C36_V58_DF047
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 86 of 431

13B-86V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF053
PRESENT
OR
STOREDRAIL PRESSURE REGULATION FUNCTION1.DEF: Above maximum threshold.
2.DEF: Negative loop deviation.
3.DEF: Positive loop deviation.
4.DEF: Below minimum threshold.
NOTESOrder of priority for a combination of faults:
Deal with fault DF643 Rail pressure regulator circuit first if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the engine is started,
– a road test.
Special notes:
If the fault is present:
– engine torque limited for 2.DEF/3.DEF,
–the level 1 warning light comes on for 2DEF/3.DEF.
–the level 2 warning light comes on for 1.DEF/3.DEF/4.DEF,
– engine stops for 1.DEF/3.DEF/4.DEF.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF053/EDC16C36_V4C_DF053/EDC16C36_V48_DF053/EDC16C36_V50_DF053/EDC16C36_V54_DF053/
EDC16C36_V58_DF053
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 88 of 431

13B-88V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
PRESENT
OR
STOREDTURBOCHARGING SOLENOID VALVE CONTROL CIRCUITCO: Open circuit
CC.1: short-circuit to + 12 V
CC.0: Short circuit to earth
1.DEF: Internal electronic fault
NOTESPriorities when dealing with a number of faults:
Deal with fault DF046 Battery voltage first, if it is present or stored.
Conditions for applying the fault finding procedure to a stored fault:
The fault is declared present after:
– the ignition is switched on.
– starting the engine,
– a road test,
– actuator command AC004 Turbocharging solenoid valve.
Special notes:
If the fault is present:
– turbocharging is no longer authorised,
– the EGR function is inhibited,
–the level 1 and European On Board Diagnostic warning lights are lit.
Use bornier Elé.1681 for any operations on the injection computer connectors.
Use Wiring Diagram Technical Note, Mégane II ph2, Scénic II ph2.
EDC16C36_V44_DF054/EDC16C36_V4C_DF054/EDC16C36_V48_DF054/EDC16C36_V50_DF054/EDC16C36_V54_DF054/
EDC16C36_V58_DF054
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 89 of 431

13B-89V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
CONTINUED 1
CONOTESNone.
Check the condition of the turbocharging solenoid valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve between the following connections:
– Connection code 3FB of component 1475.
– Connection code 3MG of component 1475.
If the resistance measured is greater than 1 kΩ or less than 6 Ω, replace the turbocharging solenoid valve.
Check the continuity of the following connections:
– Connection code 3MG between components 1475 and 120.
Check for the presence of + 12 V after relay on the turbocharging solenoid valve connector.
– Connection code 3FB of component 1475.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbocharging solenoid valve.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58
Page 90 of 431

13B-90V9 MR-372-J84-13B450$102.mif
DIESEL INJECTION
Fault finding – Interpretation of faults13B
DF054
CONTINUED 2
CC.1NOTESNone.
Check the condition of the turbocharging solenoid valve (see Wiring Diagram Technical Note, Mégane II ph2,
Scénic II ph2, component code 1475).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Mégane II ph2, Scénic II ph2, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Measure the resistance of the turbocharging solenoid valve between the following connections:
– Connection code 3FB of component 1475.
– Connection code 3MG of component 1475.
If the resistance measured is greater than 1 kΩ or less than 6 Ω, replace the turbocharging solenoid valve.
Check the continuity and insulation in relation to + 12 V of the following connection:
– Connection code 3MG between components 1475 and 120.
If there is a repair method (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the wiring, otherwise replace it.
If the fault is still present, replace the turbocharging solenoid valve.
AFTER REPAIRDeal with any other faults. Clear the fault memory.
Switch off the ignition until the end of the power-latch phase, and carry out a road test
followed by a check using the diagnostic tool.
EDC16 C36
Program No.: 91
Vdiag No.: 44, 4C, 48,
50, 54, 58