heating RENAULT SCENIC 2011 J95 / 3.G Engine And Peripherals Siemens Injection User Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2011, Model line: SCENIC, Model: RENAULT SCENIC 2011 J95 / 3.GPages: 329, PDF Size: 1.71 MB
Page 35 of 329

13B-35
MR-372-J84-13B050$390.mif
V17
13B
DIESEL INJECTION
Fault finding – Interpretation of faults
DF001
PRESENT
OR
STOREDCOOLANT TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Open circuit or short circuit to +12 V.
1. DEF: Micro-breaks
2. DEF: Signal inconsistency
NOTESConditions for application to a stored fault:
The fault is declared present after the ignition has been switched on for at least
10 seconds.
If the fault is present:
– the engine overheating warning light is lit on the instrument panel,
– the fan assemblies are running,
– the air conditioning compressor is switched off, the coolant temperature value
switches to safe mode, 10°C < PR064 Coolant Temperature < 90°C.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the coolant temperature sensor connector, component code244 (see
MR 392, 385, 364, 370 and 417, Mechanical, 19A, Cooling system, Coolant temperature sensor:
Removal - Refitting) and the injection computer, component code120 (see MR 392, 385, 364, 370 and 417,
Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Measure the resistance of the coolant temperature sensor, component code 244, between connections 3C and
3JK.
If the resistance is not:
11332Ω < X < 13588Ω at - 10°C,
2140Ω < X < 2364Ω at 25°C,
771Ω < X < 849Ω at 50°C,
275Ω < X < 291Ω at 80°C,
replace the coolant temperature sensor (see MR 392, 385, 364, 370 and 417, Mechanical, 19A, Cooling
system, Coolant temperature sensor: Removal - Refitting).
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3C between components 244 and 120.
–3JK between components 244 and 120.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF001 / SID304_V45_DF001 / SID301_V48_DF001 / SID304_V49_DF001 / SID304_V4D_DF001 / SID301_V4C_DF001
MR-372-J84-13B050$390.mif
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
Page 50 of 329

13B-50
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF017
PRESENT
OR
STOREDPRE-POSTHEATING UNIT CONTROL CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after attempts have been made to start the engine.
Special notes:
If the fault is present, it will be difficult or impossible to start the vehicle when cold, or
preheating will be continuous with damage to the heater plugs.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector for the preheating unit, component code257 or 980 (see
MR 392, 385, 364, 370 and 417, Mechanical, 13C, Preheating, Pre-post heating unit:
Removal - Refitting), the supply cables for the heater plugs (see MR 392, 385, 364, 370 and 417,
Mechanical, 13C, Preheating, Heater plugs: Removal - Refitting) and the injection computer connector,
component code120 (see MR 392, 385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection
computer: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Check the condition of the power supply fuseF2 (70A) on the power supply fuse board component code777.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3FF between components257 or 980 and 120,
–3FY between components257 or 980 and 120,
–BP35 between components257 or 980 and 777.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If these connections are correct, replace the preheating unit (see MR 392, 385, 364, 370 and 417, Mechanical,
13C, Preheating, Pre-post heating unit: Removal - Refitting).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF017 / SID304_V45_DF017 / SID301_V48_DF017 / SID304_V49_DF017 / SID304_V4D_DF017 / SID301_V4C_DF017
Page 51 of 329

13B-51
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF025
PRESENT
OR
STOREDPRE-POSTHEATING UNIT DIAGNOSTIC LINE
CC.0 : Short circuit to earth
C0.1 : Open circuit or short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault is declared present after several attempts have been made to start the
engine.
Special notes:
If the fault is present, it will be difficult or impossible to start the vehicle when cold, or
preheating will be continuous with damage to the heater plugs.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and KANGOO II Wiring
diagrams Technical Note.
Check the connection and condition of the connector for the preheating unit, component code257 or 980 (see
MR 392, 385, 364, 370 and 417, Mechanical, 13C, Preheating, Pre-post heating unit: Removal - Refitting)
and the supply cables for the heater plugs, component code257 (see MR 392, 385, 364, 370 and 417,
Mechanical, 13C, Pre-heating, Heater plugs: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Check the connection and condition of the connectors for the heater plugs, component codes680, 681, 682 and
683 (see MR 392, 385, 364, 370 and 417, Mechanical, 13C, Pre-heating, Heater plugs: Removal - Refitting)
and the injection computer connector, component code120 (see MR 392, 385, 364, 370 and 417, Mechanical,
13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair) repair the connector(s); otherwise, replace the wiring.
Measure the resistance of the heater plugs, component codes680, 681, 682 and 683.
If the resistance is not 0.6Ω at +20°C, replace the plug(s) (see MR 392, 385, 364, 370 and 417, Mechanical,
13C, Pre-heating, Heater plugs: Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF025 / SID304_V45_DF025 / SID301_V48_DF025 / SID304_V49_DF025 / SID304_V4D_DF025 / SID301_V4C_DF025
Page 52 of 329

13B-52
MR-372-J84-13B050$390.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No. 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF025
CONTINUED
Check the condition of the power supply fuseF2 (70A) on the power supply fuse board component code777.
Check the insulation, continuity and the absence of interference resistance on the following connections:
–3FF between components257 or 980 and 120,
–3FY between components257 or 980 and 120,
–BP35 between components257 or 980 and 777,
–37AC between components257 or 980 and 683,
–37Z between components257 or 980 and 680,
–37AA between components257 or 980 and 681,
–37AB between components257 or 980 and 682.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If this connection is correct, replace the preheating unit (see MR 392, 385, 364, 370 and 417, Mechanical, 13C,
Preheating, Pre-postheating unit: Removal - Refitting).
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
Page 79 of 329

13B-79
MR-372-J84-13B050$429.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF238
PRESENT
OR
STOREDTHERMOPLUNGER NO. 3 RELAY CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after starting the engine.
If the fault is present:
CC.0: The water heater interface unit is permanently actuated.
CC.1: The water heater interface unit is not actuated.
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the thermoplunger unit connector, component code 1550 (see MR 392,
385, 364, 370 and 417, Mechanical, 61A, Heating system, Heating system: List and location of
components).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for + 12 V on connections BP35 and BP36 of the thermoplunger unit, component
code 1550.
Check the continuity, insulation and the absence of interference resistance on the following connection:
–3JAB between components1550 and 120.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID304_V4D_DF238 / SID301_V4C_DF238
Page 80 of 329

13B-80
MR-372-J84-13B050$429.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF239
PRESENT
OR
STOREDTHERMOPLUNGER RELAY NO. 2 CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after starting the engine.
If the fault is present:
CC.0: The water heater interface unit is permanently actuated.
CC.1: The water heater interface unit is not actuated.
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the thermoplunger unit connector, component code 1550 (see MR 392,
385, 364, 370 and 417, Mechanical, 61A, Heating system, Heating system: List and location of
components).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for + 12 V on connections BP35 and BP36 of the thermoplunger unit, component
code 1550.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connection:
–3JAA between components 1550 and 120.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID304_V4D_DF239 / SID301_V4C_DF239
Page 81 of 329

13B-81
MR-372-J84-13B050$429.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF240
PRESENT
OR
STOREDTHERMOPLUNGER NO. 1 RELAY CIRCUIT
CC.0 : Short circuit to earth
CC.1 : Short circuit to + 12 V
CO : Open circuit
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present after starting the engine.
If the fault is present:
CC.0: The water heater interface unit is permanently actuated.
CC.1: The water heater interface unit is not actuated.
The level 1 fault warning light is lit on the instrument panel.
Use CLIO III, MODUS, MEGANE II ph2, SCENIC II ph2 and Kangoo II Wiring
diagrams Technical Note.
Check the connection and condition of the thermoplunger unit connector, component code 1550 (see MR 392,
385, 364, 370 and 417, Mechanical, 61A, Heating system, Heating system: List and location of
components).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the connection and condition of the injection computer connector, component code 120 (see MR 392,
385, 364, 370 and 417, Mechanical, 13B, Diesel injection, Diesel injection computer: Removal - Refitting).
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
With the ignition on, check for + 12 V on connections BP35 and BP36 of the thermoplunger, component code
1550.
If the connection(s) are faulty and there is a repair method (see Technical Note 6015A, Repairing electrical
wiring, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the continuity, insulation and the absence of interference resistance on the following connection:
–3JA between components 1550 and 120.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF240 / SID304_V45_DF240 / SID301_V48_DF240 / SID304_V49_DF240 / SID304_V4D_DF240 / SID301_V4C_DF240
Page 123 of 329

13B-123
MR-372-J84-13B050$468.mif
V17
DIESEL INJECTION
Fault finding – Interpretation of faults
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
13B
DF1070
PRESENT
OR
STOREDCOLD LOOP
NOTESConditions for applying the fault finding procedure to a stored fault:
The fault becomes present with the engine running and an air conditioning request.
Order of priority in the event of more than one fault:
Deal with fault DF049 Refrigerant sensor circuit first if it is present or stored.
Use the CLIO III, MODUS, MEGANE II ph2 and SCENIC II ph2 Wiring Diagrams
Technical Note.
When the fault is present or stored, the heating and air conditioning system is inhibited. There is no longer any air
conditioning.
Check the air conditioning fuse and check the air conditioning compressor connector, component code 171.
If the connector is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
Check the continuity and insulation of the following connections:
– 38R between components 171 and 1337,
– Mbetween the earth and component 171.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Manually check if the compressor is jammed (turn the clutch plate manually to check that there is no point of
resistance).
In the event of jamming, replace the air conditioning compressor (see MR 364 (Mégane II), MR 370 (Scénic II),
MR 385 (Modus), MR 392 (Clio III), Mechanical, 62A, Air conditioning, Compressor:
Removal - Refitting)
Charge the air conditioning circuit, check for any leaks and repair if necessary (see MR 364 (Mégane II), MR 370
(Scénic II), MR 385 (Modus), MR 392 (Clio III), Mechanical, 62A, Air conditioning, Air conditioning: Check
and air conditioning:
Draining - Filling).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer fault memory.
Carry out a road test followed by another check with the diagnostic tool.
SID301_V44_DF1070 / SID304_V45_DF1070 / SID301_V48_DF1070 / SID304_V49_DF1070 / SID304_V4D_DF1070 / SID301_V4C_DF1070
Page 125 of 329

13B-125
MR-372-J84-13B050$546.mif
V17
13B
DIESEL INJECTION
Fault finding – Status summary table
Tool status Diagnostic tool title
ET001Computer + after ignition feed
ET003Engine immobiliser
ET004 Air conditioning authorisation
ET006Code programmed
ET021High speed fan assembly request
ET022Low speed fan assembly request
ET023Fast idle speed request
ET028Level 1 fault warning light request
ET029Level 2 fault warning light request
ET033EGR solenoid valve
ET038Engine
ET042Cruise control/speed limiter
ET076Starting
ET077Impact detected
ET079Air conditioning present
ET088Compressor actuation request
ET121Clutch switch signal
ET148OBD warning light activation request
ET160Preheating relay control
ET228Cylinder 1 injector control
ET229Cylinder 2 injector control
ET230Cylinder 3 injector control
ET231Cylinder 4 injector control
ET238Synchronisation
ET405Clutch pedal switch
ET415Cruise control/speed limiter deactivation
ET613Fuel pressure regulator
ET638Fuel flow regulator
ET648Engine cooling fan
ET649Water in diesel fuel sensor
ET673Jammed accelerator pedal detected
MR-372-J84-13B050$546.mif
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2
Page 132 of 329

13B-132
MR-372-J84-13B050$585.mif
V17
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B1 and B2DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET021
HIGH-SPEED FAN REQUEST
STATUS DEFINITION"ACTIVE": The status indicates that the high-speed fan request is active.
"INACTIVE": The status indicates that the high-speed fan request is not active.
NOTESSpecial notes:
Only perform these tests if the status does not correspond with the system
programming functions.
NOTE:
Status ET021 "High-speed fan request" changes status simultaneously.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant temperature
>80 °C
ACTIVE
The injection computer requests the activation of the high speed GMV when:
– the engine coolant temperature is above 104 °C.
– the injection computer has system faults that could lead to the engine
overheating.
When the high speed fan is supplied:
status ET021 High speed fan request becomes ACTIVE.
INACTIVEThe high-speed engine fan assembly stops when:
– the engine coolant temperature is below 102 °C;
– no fault which could cause engine overheating is present in the injection
system.
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
SID301_V44_ET021/SID304_V45_ET021/SID301_V48_ET021/SID304_V49_ET021/SID304_V4D_ET021/SID301_V4C_ET021