13B-181
MR-372-J84-13B050$624.mif
V17
Siemens Injection
SID301 and 304
Vdiag No.: 44-45-48-49-4D-4C
Program No.: B2DIESEL INJECTION
Fault finding – Interpretation of statuses13B
ET704
ET705
BRAKE SWITCH NO. 1
BRAKE SWITCH NO. 2
STATUS DEFINITIONACTIVE: This status indicates that the brake pedal is depressed.
INACTIVE This status indicates that the brake pedal is released.
NOTESSpecial note:
Only perform these tests if the status does not correspond with the system
programming functions.
Use the Wiring Diagram Technical Note for Mégane II ph2, Scénic II ph2, CLIO III,
MODUS and Kangoo II.
Note:
Statuses ET704 and ET705 should change status at the same time. If they do not, consult the interpretation of
faults DF008 Pedal potentiometer circuit gang 1 and DF009 Pedal potentiometer circuit gang 2.
ACTIVE
If the brake lights are working:
– check the continuity and make sure there is no interference resistance on the
following connection:
Connection code 5A between components 160 and 120, 645 and 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A,
Electrical wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise
replace it.
If the brake lights are not operational, check:
– the condition and fitting of the brake switch,
– the condition and conformity of the brake light fuse,
– the conformity of the values in the following table:
Continuity between
connectionsInsulation between
connections
Switch pressed
(Brake pedal released)5A and BPT 65G and SP17
Switch released
(Brake pedal depressed)65G and SP17 5A and BPT
or
INACTIVE
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
SID301_V44_ET704/SID304_V45_ET704/SID301_V48_ET704/SID304_V49_ET704/SID304_V4D_ET704/SID301_V4C_ET704
SID301_V44_ET705/SID304_V45_ET705/SID301_V48_ET705/SID304_V49_ET705/SID304_V4D_ET705/SID301_V4C_ET705