THERMO PLUNGER RENAULT SCENIC 2012 J95 / 3.G Engine And Peripherals EDC16CP33 Owner's Guide
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2012, Model line: SCENIC, Model: RENAULT SCENIC 2012 J95 / 3.GPages: 510, PDF Size: 2.98 MB
Page 447 of 510

13B-447V12 MR-372-J84-13B300$150.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
* supplier: Champion: the load resistance is between: 547 mΩ < X < 669 mΩ.
AC063
CONTINUED
If the Thermoplunger no. 1 relay or the additional heater interface unit functions using command AC063,
but there is still a passenger compartment heating/demisting problem, check using the wiring diagram:
The conformity of the thermoplunger maxi-fuse.
Check for + 12 V battery on connection BP9 of component 1067 or 1550.
Check the conformity of the thermoplunger no. 1 relay or the additional heater interface unit.
Check the continuity of connection 3JB between components 1067 or 1550 and 998.
Measure the resistance of the thermoplunger*.
The presence of earth on the water chamber (thermoplunger mounting).
Also check the level of the cooling circuit and that there are no leaks.
Carry out the necessary repairs.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 448 of 510

13B-448V12 MR-372-J84-13B300$150.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
AC064THERMOPLUNGER No. 2 RELAY
NOTESThere must be no present or stored faults.
Perform this fault finding procedure if there is a fault with the passenger compartment
heating - demisting.
Consult the "Wiring diagrams" Technical Note to locate the relevant fuses and relays.
Special notes:
The thermoplunger no. 2 relay or the additional heater interface unit supplies
thermoplungers 2 and 3 in parallel.
Use the Wiring Diagram Technical Note, Laguna II ph2, Vel Satis ph2, Espace IV
ph2, Mégane II ph2, Scénic II ph2.
If the thermoplunger no. 2 relay does not operate during command AC064.
Check the condition of the thermoplunger 2 relay mounting on the engine fuse box or the additional heater
interface unit (see Wiring Diagram Technical Note, Vehicle, component code 1068 or 1550).
Check the condition of the engine management computer connector (see Wiring Diagram Technical Note,
Vehicle, component code 120).
If the connector or connectors are faulty and if there is a repair procedure (see Technical Note 6015A, Repairing
electrical wiring, Wiring: Precautions for repair), repair the connector, otherwise replace the wiring.
if the fault is still present, check as follows that this relay is controlled by the engine management computer:
Disconnect the thermoplunger no. 2 relay, fit a 50 Ω to 100 Ω resistor on its mounting instead of the coil, and
connect a voltmeter as follows:
– positive terminal to + 12 V battery,
– negative terminal on connection 3JAA of component 1068 or 1550.
Run command AC064.
If the voltmeter shows the battery voltage (4 ON-OFF cycles of 10 seconds), replace the thermoplunger no. 2
relay.
If the voltmeter does not show the battery voltage (4 ON-OFF cycles of 10 seconds), contact the Techline.
EDC16CP33_V18_AC064 / EDC16CP33_V1C_AC064 / EDC16CP33_V54_AC064 / EDC16CP33_V20_AC064 / EDC16CP33_V58_AC064 /
EDC16CP33_V5C_AC064 / EDC16CP33_V24_AC064 / EDC16CP33_V04_AC064 / EDC16CP33_V08_AC064 / EDC16CP33_V44_AC064 /
EDC16CP33_V4C_AC064 / EDC16CP33_V34_AC064 / EDC16CP33_V38_AC064 / EDC16CP33_V74_AC064 / EDC16CP33_V28_AC064 /
EDC16CP33_V62_AC064 / EDC16CP33_V26_AC064 / EDC16CP33_V60_AC064
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.
Page 449 of 510

13B-449V12 MR-372-J84-13B300$150.mif
DIESEL INJECTION
Fault finding – Interpretation of commands13B
* supplier: Champion: the load resistance is between: 547 mΩ < X < 669 mΩ.
AC064
CONTINUEDTHERMOPLUNGER No. 2 RELAY
If thermoplunger no. 2 relay operates with command AC064, but there is still a passenger compartment
heating/demisting fault, use the wiring diagram to check:
The conformity of the thermoplunger maxi-fuse.
Check for + 12 V battery on connection BP91 of component 1068 or 1550
Check the conformity of thermoplunger no. 2 relay.
Check the continuity of connection 3JAD or 3JD and 3JAC between components 1068 or 1550 and (1072 and
1073).
Measure the resistances of the thermoplungers*
The presence of earth on the water chamber (thermoplunger mounting).
Also check the level of the cooling circuit and that there are no leaks.
Carry out the necessary repairs.
EDC16CP33
Program No.: C4
Vdiag No.: 04, 08, 18, 1C,
20, 24, 26, 28, 34, 38, 44,
4C, 54, 58, 5C, 60, 62, 74
AFTER REPAIRCarry out a road test, then check with the diagnostic tool.