PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-60V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF088
PRESENT
OR
STOREDPINKING SENSOR CIRCUIT
1.DEF : pinking signal fault
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present in a warm engine road test at an engine speed of more
than 2500 rpm.
Special note:
–OBD warning light illuminated.
Check the cleanliness and condition of the pinking sensor and its connections.
Check the tightness of the pinking sensor.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Using the universal bornier, check for insulation and continuity on the following connections:
Computer, connector B, track B3 Track 2 of the pinking sensor
Computer, connector B, track B4 Track 1 of the pinking sensor
Computer, connectorB, track B2 Shielding of the pinking sensor
Repair if necessary.
Check the conformity of the fuel in the tank.
Check the conformity of the spark plugs.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
JSAA741.0
Page 62 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-62V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF091
PRESENT
OR
STOREDVEHICLE SPEED SIGNAL
1.DEF : error in speed signal from the ABS
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running.
Special note:
–OBD warning light illuminated.
Run a multiplex network test (see88B, Multiplex).
If the fault is still present, carry out fault finding on the ABS - ESP system (see38C, Anti-lock braking system).
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 63 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-63V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF092
PRESENT
OR
STOREDUPSTREAM OXYGEN SENSOR CIRCUIT
CO.0 : open circuit or short circuit to earth
CC.1 : short circuit to + 12 V
1.DEF : component in bad condition
NOTESPriority for dealing with a combination of faults:
Apply the procedure for dealing with faults DF011 Sensor supply voltage no. 1,
DF046 Battery voltage, DF082 Upstream oxygen sensor heating circuit or DF084
Actuator control relay circuit first if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running after 5 minutes in richness
regulation.
Special note:
–OBD warning light illuminated.
Check the cleanliness and condition of the upstream oxygen sensor connections.
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Using the Universal bornier, check the insulation and continuity of the following connections:
Computer, connectorC, track C1 Track D of the upstream oxygen sensor
Computer, connectorC, track B1 Track C of the upstream oxygen sensor
Repair if necessary.
Check the condition of the oxygen sensor, use command SC007 Run OBD Test: O2 sensor.
If the fault persists, contact your Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 65 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-65V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF095
PRESENT
OR
STOREDTHROTTLE POTENTIOMETER CIRCUIT GANG 1
CO.0 : open circuit or short circuit to earth
CC.1 : short circuit to + 12 V
1.DEF : inconsistency between throttle gang 1 and gang 2
WARNING
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESPriority for dealing with a combination of faults:
If the fault DF011 Sensor supply voltage no. 1 is present or stored, handle it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present after a change in the engine speed.
Special note:
–level 1 fault warning light illuminated.
– Throttle valve defect mode types 1, 2 and 6.
Check the cleanliness of the throttle valve and that the throttle rotates properly (no hard point).
Check the cleanliness and condition of the throttle valve connections.
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Using the Universal bornier, check the insulation and continuity of the following connections:
Computer, connectorB, track G4 Track 1 of the throttle potentiometer gang 1
Computer, connectorB, track G3 Track 2 of the throttle potentiometer gang 1
Computer, connectorB, track G2 Track 5 of the throttle potentiometer gang 1
Repair if necessary.
If the throttle body is replaced, reinitialise the programming (RZ005).
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 66 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-66V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF096
PRESENT
OR
STOREDTHROTTLE POTENTIOMETER CIRCUIT GANG 2
CO.1 : open circuit or short circuit to +12 V
CC.0 : short circuit to earth
WARNING
Never drive the vehicle without having confirmed that no faults involving the throttle valve are present.
NOTESPriority for dealing with a combination of faults:
If the fault DF011 Sensor supply voltage no. 1 is present or stored, handle it first.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present after a change in the engine speed.
Special note:
–level 1 fault warning light illuminated.
– throttle valve defect mode types 4 and 6.
Check the cleanliness of the throttle valve and the correct rotation of the throttle (no hard point).
Check the cleanliness and condition of the throttle valve connections.
Repair if necessary.
Disconnect the battery and the injection computer.
Check the cleanliness and condition of the connections.
Use the universal bornier to check the insulation and continuity of the following connections:
Computer, connector B, track D3 Track 6 of the throttle potentiometer gang 2
Computer, connectorB, track G2 Track 5 of the throttle potentiometer gang 2
Computer, connectorB, track G4 Track 1 of the throttle potentiometer gang 2
Repair if necessary.
If the throttle valve has been replaced, reinitialise RZ005 Programming.
If the fault is still present, deal with the other faults then proceed to the conformity check.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 73 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-73V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF109
PRESENT
OR
STOREDLOW FUEL LEVEL MISFIRING
1.DEF : destructive misfiring
2.DEF : pollutant misfiring
NOTESPriority for dealing with a combination of faults:
– fuel supply system: DF085, DF026, DF027, DF028 and DF029.
– combustion misfire: DF059, DF060, DF061, DF062, DF065 with 1.DEF or 2.DEF.
Conditions for applying the fault finding procedure to stored faults:
The fault is present after starting the engine and under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (minimum 75°C).
– idling with all the electrical consumers activated for 15 minutes.
Special note:
–OBD warning light illuminated.
Check that there is fuel in the tank.
Check that the correct fuel is being used.
If there is no present or stored misfiring fault, the misfiring was caused by the low fuel level.
Clear fault DF109.
– Carry out the steps "according to the repair".
AFTER REPAIREnsure that all the faults have been dealt with.
Do not clear the programming.
Checking that the system has been properly repaired:
– there must be no further electrical faults,
– programming has been carried out,
– warm engine (minimum 75°C).
– running at idle speed with all electrical consumers drawing power for 15 minutes.
– if the fault is still absent, check that the catalytic converter is in good condition. Use
command SC006 Run OBD Test: Catalytic converter.
JSAA741.0
Page 74 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-74V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF110
PRESENT
OR
STOREDCATALYTIC CONVERTER
1.DEF : EOBD HC pollutant emissions threshold has been exceeded
NOTESPriority for dealing with a combination of faults:
Deal with the other faults first.
There must be no other injection system faults, either present or stored.
– combustion misfire: DF059, DF060, DF061, DF062, DF065 in 1.DEF or 2.DEF.
Conditions for applying the fault finding procedure to stored faults:
The fault is considered present under the following conditions:
– there must be no further electrical faults,
– programming must be carried out.
– warm engine (minimum 75°C).
– idling with all the electrical consumers activated for 15 minutes.
Special note:
–OBD warning light illuminated.
Use command SC006 Run OBD Test: Catalytic converter.
This command must not be performed on a new catalytic converter; the result would be incorrect.
If the fault persists, contact your Techline.
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 76 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-76V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF125
PRESENT
OR
STOREDTORQUE METER PROGRAMMING
1.DEF : programming not carried out
NOTESSignal:
The torque meter analyses the crankshaft speed.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the starter motor has been running for 10 seconds
or at an engine speed above 600 rpm.
Special note:
–OBD warning light illuminated.
Reinitialising the programming:
Run command RZ005.
Torque meter programming:
Accelerate up to 4000 rpm in third gear then decelerate at no load to power take-up speed*.
Then repeat immediately.
In rare cases, fault DF125 may appear.
(*This is the moment when, during deceleration with no load, the engine drops to idle speed and recovers torque)
AFTER REPAIRDeal with any faults declared by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
JSAA741.0
Page 80 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B-80V12 MR-372-J84-17B000$360.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF154
PRESENT
OR
STOREDFLYWHEEL SIGNAL SENSOR CIRCUIT
1.DEF : flywheel target fault
2.DEF : no speed signal or interference signal
NOTESPriority for dealing with a combination of faults:
In the event of a fault DF154, DF119 Camshaft sensor signal and DF080 Camshaft
dephaser circuit, ignore fault DF080 and deal with the other 2 faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after the starter motor has been running for 10 seconds
or at an engine speed above 600 rpm.
Special note:
–OBD warning light illuminated.
Check the cleanliness, condition and the assembly of the flywheel.
Repair if necessary.
If the flywheel has been replaced or removed, the flywheel target has to be reinitialised, then reprogrammed.
Programming reinitialisation:
Run command RZ005.
Carrying out the flywheel target programming:
Accelerate up to 4000 rpm in third gear then decelerate, foot off the pedal, to power take-up speed*.
Then repeat immediately.
In rare cases, fault DF125 Torquemeter programming may appear.
(*This is the moment when, during deceleration with no load, the engine drops to idle speed and recovers torque).
S3000_V44_DF154/S3000_V48_DF154JSAA741.0
Page 81 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 81V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Interpretation of faults
DF398
PRESENT
OR
STOREDFUEL CIRCUIT OPERATING FAULT
1.DEF : petrol circuit fault
NOTESPriority for dealing with a combination of faults:
Apply the procedure for dealing with faults DF081 Solenoid valve canister bleed and
DF085 Fuel pump relay first if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after an attempt is made to start the engine.
Special note:
–OBD warning light comes on.
Check the cleanliness, condition and fitting of the fuel vapour absorber.
Repair if necessary.
If the fault is still present, adjust the harness so that the fault status changes (present stored).
Look for any damage to the wiring harness, and check the condition and connection of the injection computer
and fuel vapour absorber connectors.
Repair if necessary.
If the fault is still present, check for the +12V on track 1 of the fuel vapour absorber.
If the +12V is not present, check the following connection for insulation, continuity and the absence of
interference resistance:
Fuel vapour absorber track 1 track 2 of connector PPM1 on the Protection and Switching Unit
Repair if necessary.
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity and the absence of interference resistance on the following connection:
Computer, connectorC, track E1petrol vapour absorber track 2
Repair if necessary.
If the fault is still present, measure the resistance between tracks 1 and 2 of the fuel vapour absorber bleed
solenoid valve.
Replace the bleed solenoid valve for the fuel vapour absorber if the resistance is not 26 ±4 at 23 °C.
If the fault is still present, check the insulation, continuity and the absence of interference resistance on the
following connections:
Computer, connectorC, track D1 track 1 of the PEM connector of the Protection
and Switching Unit
Repair if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V44_DF398/S3000_V48_DF398JSAA741.0
MR-372-J84-17B000$405.mif