POWER – ASSISTED STEERING
Fault finding – Function
Column steering system
1Computer
2Computer supply
3+ after ignition feed
4Vehicle speed
5Engine speed
6K line
7Fault warning light
8+ torque sensor
9Main signal
10 Secondary signal
11 0 V
12 + angle sensor (only in Vdiag 04)
13 Signal 1 (only in Vdiag 04)
14 Signal 2 (only in Vdiag 04)
15 0 V (only in Vdiag 04)
16 Brush motor supply
17 Power-assisted steering motor
18 Torque sensor
19 Angle sensor (only in Vdiag 04)
EPAS
Vdiag No.: 04 - 08
MR-413-X44-36B000$268.mif
Page 15 of 54

36B-15
MR-413-X44-36B000$469.mif
V2
36B
POWER – ASSISTED STEERING
Fault finding – Fault summary table
Tool fault Diagnostic tool titleAssociated
DTCCustomer complaints and warning
light coming on
DF001Motor thermal protection5660Steering assistance intermittent
reduction (no warning light or buzzer)
DF002Computer5640No assistance on start-up or sudden
loss of assistance with EPAS fault
warning light, STOP warning light and
buzzer
DF017Motor circuit5630Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF023+ after ignition feed5622Gradual loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF028Engine speed zero5621Incorrect level of assistance (no warning
light or buzzer)
DF037Battery voltage5650Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF038Angle sensor5610Loss of "active return" function with no
warning light
DF039Torque sensor circuit5603Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF043Vehicle speed5620Incorrect level of assistance (no warning
light or buzzer)
DF048Torque sensor circuit5602Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF050Torque sensor circuit signal 25601Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
DF054Torque sensor5600Sudden loss of assistance with EPAS
fault warning light, STOP warning light
and buzzer
EPAS
Vdiag No.: 04 - 08
MR-413-X44-36B000$469.mif
Page 16 of 54

36B-16
MR-413-X44-36B000$469.mif
V2
EPAS
Vdiag No.: 04 - 08
36B
DF001
PRESENT
OR
STOREDMOTOR THERMAL PROTECTION
DEF: Operating temperature too high
NOTESConditions for applying the fault finding procedure to stored faults:
Apply this fault finding procedure even if the fault is stored.
Notes:
This fault does not indicate a system failure, but indicates overheating either of the
Electric Power-Assisted Steering (EPAS) motor or of the computer during repeated
manoeuvres.This fault may appear after the steering wheel is moved repeatedly
(parking) and causes a gradual reduction in steering but the fault warning light does
not come on.
Use the diagnostic tool to check the conformity of PR129 Motor power (60 A) and PR130 Motor power (45 A)
(zero in absence of PR001 Torque applied to steering wheel).
Contact the Techline in the event of any nonconformity.
Check the conformity of the computer and steering column (45 or 60 A) in relation to the table below:
Left-hand drive Right-hand drive
Torque sensor wiring harness blue black
Motor wiring45 Agreen black
Motor wiring60 Ablue grey
45 A 60 A
Computer label yellow white
In the event of a nonconformity, consult "RENAULT NET" to repair the vehicle according to the technical vehicle
definition.
Disconnect the battery then allow the electric power-assisted steering to cool down.
Reconnect the battery, clear the faults, start the vehicle and check the operation of the electric power-assisted
steering by turning the steering wheel full lock to the left or right.
The fault should not recur in the next 30 seconds.
If the fault recurs as present or stored, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF001 /DAE_V08_DF001
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
Page 17 of 54

36B-17
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF002
PRESENT
OR
STOREDCOMPUTER
1. DEF: + After relay supply fault
2. DEF: Internal electronic fault
NOTESPriority in the event of a number of faults:
In the event of numerous faults, deal with the other present and stored faults before
applying the fault finding procedure for this fault.
Conditions for applying the fault finding procedure to stored faults:
Apply the fault finding procedure even if the fault is stored.
Notes:
This fault causes:
No assistance on start-up or sudden loss of assistance with illumination of the
Fault warning light + STOP + Beep.
Contact Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF002 /DAE_V08_DF002
Page 18 of 54

36B-18
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF017
PRESENT
OR
STOREDMOTOR CIRCUIT
DEF : Short circuit to earth or short circuit to 12 V
CC.O : Short circuit to earth
CO : Open circuit
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after the engine was started and after turning the
steering wheel from lock to lock, then returning it to the centre.
Notes:
This fault causes:
Sudden loss of steering assistance with illumination of the Fault warning light +
STOP + Beep.
Use the Wiring Diagram Technical Note for New Twingo.
With + after ignition feed off, check the connection and condition (possible wiring damage) of the connector of
component 502 and its clips.
If the connector is faulty (see Technical Note 6015A, Electrical wiring repair, Wiring: Precautions for repair),
repair the connector, otherwise replace the steering column.
Connector of component 502 and component 540 disconnected: check the insulation against +, -, and between
the connections and check the continuity of the following connections:
●Connection 109R
●Connection 109S
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the connectors or the wiring, otherwise replace the steering column.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF017 /DAE_V08_DF017
Page 19 of 54

36B-19
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF023
STORED
+ AFTER IGNITION FEED
CO.O: Open circuit or short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is stored after the after ignition feed is switched off at speeds over 6 mph
(10 km/h).
Notes:
This fault causes:
Sudden loss of steering assistance with illumination of the Fault warning light +
STOP + Beep.
Use the Wiring Diagram Technical Note for New Twingo.
Important note: this fault may indicate the system is being incorrectly used by the customer (ignition cut off at
speeds over 6 mph (10 km/h)).
In this instance, this fault should be ignored.
With + after ignition feed off, check the connection and condition (possible wiring damage) of the connector
of component 502 and its clips.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the connector, otherwise replace the wiring.
With the connector of component 1016 disconnected, check the insulation and continuity of connection AP23
between components 502 and 1016.
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
If the checks reveal no faults, perform a conformity check of component 1016.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF023M/ DAE_V08_DF023M
Page 20 of 54

36B-20
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF028
PRESENT
OR
STOREDENGINE SPEED ABSENT
DEF: Open circuit, short circuit to earth or short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after having started the engine and turned the steering
wheel from lock to lock, then returning it to the centre.
Notes:
This fault causes:
No assistance with illumination of the Fault warning light + STOP + Beep.
Use the Wiring Diagram Technical Note for New Twingo.
Start the vehicle and use the diagnostic tool to check the conformity of PR004 Engine speed (not zero).
If necessary, carry out a fault finding procedure on the injection system.
With + after ignition feed off, check the connection and condition (possible wiring damage) of the connector of
component 502 and its clips.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the connector, otherwise replace the wiring.
With the connector of component 502 and intermediate connector R107 disconnected: check the insulation and
the continuity of connection H7 between component 502 and intermediate connector R107.
Connector of components 119 and 120 disconnected: check the insulation and the continuity of connection H7
between component 120 and intermediate connector R107.
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the wiring.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF028 /DAE_V08_DF028
Page 21 of 54

36B-21
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF037
PRESENT
OR
STOREDBATTERY VOLTAGE
1. DEF: Under voltage
2. DEF: Excess voltage
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after starting the engine and turning the steering wheel
from lock to lock left to right.
Notes:
This fault causes:
Sudden loss of steering assistance with illumination of the Fault warning light +
STOP + Beep.
Use the Wiring Diagram Technical Note for New Twingo.
Check the tightness and condition of the battery terminals (see 80A, Battery).
Check the charging circuit (see 16A, Starting - Charging).
Check the condition and position of the 80 A fuse in the engine fuse and relay box.
Check the condition and position of fuse F3 (15 A) fuse in the passenger compartment fuse box (see 81C,
Fuse box).
With the ignition on and the engine stopped, check for a voltage equal to the battery voltage on connections BP81
and AP23 against earth ML.
With the connectors of component 502 disconnected, check the condition and conformity of the connectors and
their clips.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for
repair), repair the connector, otherwise replace the wiring.
With the connectors of components 597 and 1016 disconnected:
Check the continuity and insulation of connection BP81 between components 502 and 597.
Check the continuity and insulation of connection AP23 between components 502 and 1016.
Check the continuity and insulation of connection ML of component 502.
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
If the checks reveal no faults, check the conformity of components 597 and 1016.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF037/DAE_V08_DF037
Page 22 of 54

36B-22
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults36B
EPAS
Vdiag No.: 04
DF038
PRESENT
OR
STOREDANGLE SENSOR
DEF: Open circuit, short circuit to earth or short circuit to + 12 V
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after having started the engine and turned the steering
wheel from lock to lock, then returning it to the centre.
Notes:
This fault causes:
Loss of the "active return" function with no fault warning light or Beep.
Use the Wiring Diagram Technical Note for New Twingo.
With + after ignition feed off, check the connection and condition (possible wiring damage) of the connector of
component 502 and its clips.
With + after ignition feed off, check the connection and condition (possible wiring damage) of connector E and its
clips of component 583.
If the connector is faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair) repair the wiring, otherwise replace it.
Visually check the condition of the wiring harness of component 583 (for possible wiring damage).
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the steering column.
With the connectors of components 502 and 583 disconnected: check the continuity and insulation of the
following connections between components 502 and 583:
●Connection 109F
●Connection 109Z
●Connection 109X
●Connection 109I
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the steering column.
Check the condition of the tabs of the connections of component 502.
Contact the Techline in the event of any nonconformity.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF038
Page 23 of 54

36B-23
MR-413-X44-36B000$469.mif
V2
POWER – ASSISTED STEERING
Fault finding – Interpretation of faults
EPAS
Vdiag No.: 04 - 08
36B
DF039
DF048
DF050
DF054
PRESENT
OR
STOREDTORQUE SENSOR CIRCUIT
TORQUE SENSOR CIRCUIT
TORQUE SENSOR CIRCUIT SIGNAL 2
TORQUE SENSOR
CO.O: Open circuit or short circuit to earth
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after having started the engine and turned the steering
wheel from lock to lock, then returning it to the centre.
Notes:
This fault causes:
Sudden loss of steering assistance with illumination of the Fault warning light +
STOP + Beep.
Use the Wiring Diagram Technical Note for New Twingo.
With + after ignition feed off, check the connection and condition (possible wiring damage) of connector C and
its clips of component 502.
If the connector is faulty (see Technical Note 6015A, Electrical wiring repair, Wiring: Precautions for repair)
repair the wiring, otherwise replace it.
Visually check the condition of the wiring harness of component 850 (for possible wiring damage).
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the steering column.
With the connectors of components 502 and 850 disconnected, check the continuity and insulation of the
following connections between components 502 and 850.
●Connection 109K
●Connection 109M
●Connection 109N
●Connection 109P
If the connection or connections are faulty (see Technical Note 6015A, Electrical wiring repair, Wiring:
Precautions for repair), repair the wiring, otherwise replace the steering column.
With + after ignition feed off, disconnect and check the condition and conformity of connector C and its clips.
Visually check the condition of the torque sensor wiring harness.
In the event of a nonconformity, replace the steering column.
Check the condition of the connection pins of components 502 and 850.
Contact the Techline in the event of any nonconformity.
If the fault is still present, contact the Techline.
AFTER REPAIRDeal with any other faults.
Clear the stored faults.
Check that the EPAS is working.
DAE_V04_DF039/DAE_V08_DF039/DAE_V04_DF048/DAE_V08_DF048
DAE_V04_DF050/DAE_V08_DF050/DAE_V04_DF054/DAE_V08_DF054