engine coolant RENAULT TWINGO RS 2009 2.G Electrical Equipment - Petrol Injection Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO RS, Model: RENAULT TWINGO RS 2009 2.GPages: 348
Page 285 of 348

17B-285V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
* MOT.: motorised
PR097MOT.* THROTTLE VALVE LOWER STOP PROGRAMMED VALUE
PARAMETER
DEFINITIONThis parameter indicates the programmed throttle valve lower stop value in %.
NOTESThere must be no present or stored faults.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The value should be:
PR097 ≈ 9%.
If there is a fault, apply interpretation for ET051 Throttle stop programming.
SIM32_V44_PR097/SIM32_V4C_PR097/SIM32_V50_PR097/SIM32_V54_PR097
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 286 of 348

17B-286V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR098UPSTREAM OXYGEN SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the upstream oxygen sensor voltage in volts.
NOTESThere must be no present or stored faults.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The value should be between:
0.1 mV < PR098 < 0.8 mV.
In the event of a fault, apply the interpretation of DF092 Upstream oxygen sensor circuit.
SIM32_V44_PR098/SIM32_V4C_PR098/SIM32_V50_PR098/SIM32_V54_PR098
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 287 of 348

17B-287V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR099DOWNSTREAM OXYGEN SENSOR VOLTAGE
PARAMETER
DEFINITIONThis parameter indicates the downstream oxygen sensor voltage in volts.
NOTESThere must be no present or stored faults.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The value should be between:
0.1 V < PR099 < 0.8 V.
In the event of a fault, apply interpretation of DF093 Downstream oxygen sensor circuit.
SIM32_V44_PR099/SIM32_V4C_PR099/SIM32_V50_PR099/SIM32_V54_PR099
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 288 of 348

17B-288V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR101INJECTION DURATION
PARAMETER
DEFINITIONThis parameter indicates the injection duration in mV.
NOTESThere must be no present or stored faults.
Conformity check with engine stopped and ignition on.
Indicates the injection duration in mV.
The value should be:
PR101 = 0 mV
Conformity check with the engine running and engine coolant temperature > 80˚C
Indicates the injection duration in mV.
The value should be:
PR101 = 5 mV
SIM32_V44_PR101/SIM32_V4C_PR101/SIM32_V50_PR101/SIM32_V54_PR101
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 289 of 348

17B-289V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
* ocr = opening cyclic ratio
PR102CANISTER BLEED SOLENOID VALVE OCR*
PARAMETER
DEFINITIONThis parameter indicates the canister bleed solenoid valve opening cyclic ratio in %.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The value should be:
PR102 ≈ 0%
SIM32_V44_PR102/SIM32_V4C_PR102/SIM32_V50_PR102/SIM32_V54_PR102
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 290 of 348

17B-290V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR103CURRENT FUEL CONSUMPTION
PARAMETER
DEFINITIONThis parameter indicates the current fuel consumption in l/h.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
This value changes according to the engine load.
SIM32_V44_PR103/SIM32_V4C_PR103/SIM32_V50_PR103/SIM32_V54_PR103
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 291 of 348

17B-291V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
(Vdiag 54 only)
* OCR: opening cycle ratio
* EV: Solenoid valve
PR104Turbocharging EV* OCR* setpoint
PARAMETER
DEFINITIONThis parameter indicates the turbocharging solenoid valve opening cyclic ratio in %.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
This percentage is 0% and increases according to the engine load.
SIM32_V54_PR104
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 292 of 348

17B-292V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR105MILEAGE COUNTER OBD FAULT WARNING LIGHT LIT
PARAMETER
DEFINITIONThis parameter indicates the mileage travelled with the On Board Diagnostics warning
light lit in miles (km).
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The mileage varies according to the time the On Board Diagnostics warning light has been lit.
SIM32_V44_PR105/SIM32_V4C_PR105/SIM32_V50_PR105/SIM32_V54_PR105
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 293 of 348

17B-293V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
PR106MILEAGE COUNTER FAULT WARNING LIGHT LIT
PARAMETER
DEFINITIONThis parameter is for viewing the mileage travelled with one of the injection fault warning
lights lit: fault level 1 (amber) and level 2 (red) warning lights.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The mileage varies according to the time a warning light is lit: fault level 1 (amber) and 2 (red) warning lights.
SIM32_V44_PR106/SIM32_V4C_PR106/SIM32_V50_PR106/SIM32_V54_PR106
AFTER REPAIRCarry out a road test followed by a check with the diagnostic tool.
Page 294 of 348

17B-294V7 MR-413-X44-17B000$171.mif
PETROL INJECTION
Fault finding – Interpretation of parameters17B
SIM 32 Injection
Program no.: D3
Vdiag No.: 44, 4C, 50
and 54
* MOT.: motorised
PR111MOT.* THROTTLE POSITION CORRECTED VALUE
PARAMETER
DEFINITIONThis parameter shows the motorised throttle position corrected value in %.
NOTESSpecial notes:
Only perform these tests if the parameters do not correspond with the system operation
programming.
Conformity check with engine stopped and ignition on, or engine running, and engine coolant
temperature > 80˚C
The value should be:
–No load < 15%
–Full load > 30%
Run command RZ005 Programming.
If the parameters or statuses are still not correct, contact the Techline.
SIM32_V44_PR111/SIM32_V4C_PR111/SIM32_V50_PR111/SIM32_V54_PR111