interior lights RENAULT TWINGO RS 2009 2.G Heating And Air Conditioning - Climate Control Workshop Manual
[x] Cancel search | Manufacturer: RENAULT, Model Year: 2009, Model line: TWINGO RS, Model: RENAULT TWINGO RS 2009 2.GPages: 99
Page 17 of 99
62B-17
MR-413-X44-62B000$230_eng.mif
V1
62B
CLIMATE CONTROL
Fault finding - Function
GENERAL INFORMATION:
The climate control function which is fitted to the new Twingo depends on the three computers: injection, UCH and
climate control (DISTRIBUTED FUNCTION).
Fault finding on the air conditioning is performed in two different ways using the diagnostic tool.
The first procedure consists of performing fault finding on each computer which allows dialogue to be established
with just one computer (select the climate control computer).
The second procedure consists of performing fault finding on each function which allows communication with all
three computers belonging to the CLIMATE CONTROL function.
DESCRIPTION OF THE OPERATION OF THE CLIMATE CONTROL COMPUTER:
The climate control computer controls the passenger compartment ventilation, the distribution motor, the mixing
motor and the recirculation motor.
The climate control computer also controls the interior temperature sensor.
The sensor and the three motors are connected to the climate control computer by wire connections. The climate
control computer controls the passenger compartment ventilation using a modulated control signal (square pulse
signal) sent to a power module (MVPE) by a wire connection.
All other signals used by the climate control computer or transmitted by this computer to other computers are sent on
the multiplex network.
The production of cold air (cold loop) and hot air (heating) is controlled by the other two computers involved in the
CLIMATE CONTROL function (UCH and engine injection computer).
Special notes on operation:
–When the engine is stopped, the passenger compartment fan rotates more slowly than when the engine is
running.
–If any of the actuators are faulty, the air conditioning can no longer control them, but the setting requests are still
displayed on the control panel: warning lights light up, display of symbols on the control panel (distribution motor
position, passenger compartment blower speed, AC symbol, etc.).
Vdiag No.: 44
MR-413-X44-62B000$230_eng.mif
Page 26 of 99
62B-26
MR-413-X44-62B000$414_eng.mif
V1
CLIMATE CONTROL
Fault finding - Interpretation of faults
Vdiag No.: 44
62B
DF007
PRESENT
OR
STOREDINTERIOR TEMPERATURE SENSOR CIRCUIT
CC.0 : Short circuit to earth
CO.1 : Short circuit or open circuit to + 12 V
NOTESConditions for running fault finding on a present or stored fault:
Apply this fault finding procedure if the fault reappears as present or stored after the
ignition is switched on and air conditioning activation is requested with the engine
running.
Special notes:
The interior temperature sensor is located at the top of the roof in the unit under the
rear view mirror.
Use the Wiring Diagram Technical Note for the New Twingo.
Check the connection and condition (possible wiring damage) of the connector of component 1872.
If the connector is faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring: Precautions for the
repair), repair the connector, otherwise replace the wiring.
With connector A of component 419 and connector of union R301 disconnected, check the insulation and
continuity of the following connections between components R301 (dashboard/interior lights intermediate union)
and 419.
●connection 38JN
●connection 38GZ
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
With the connector of component 1872 disconnected, check the insulation and continuity of the following
connections between components R301 (dashboard/interior lights intermediate union) and 1872.
●connection 38JN
●connection 38GZ
If the connection or connections are faulty (see Technical Note 6015A, Repairing electrical wiring, Wiring:
Precautions for repair), repair the wiring, otherwise replace it.
Check the insulation of connections 38JN and 38GZ of component 1872.
If the connection or connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical
wiring repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the resistance of component 1872 between connections 38JN and 38GZ.
Replace the sensor if the resistance is not 10 kΩΩ Ω Ω
± 500 ΩΩ Ω Ω
at 25 ˚C. For more details, consult the electrical
specifications of the sensor according to the temperature (see Help).
If the fault is still present, contact the Techline.
AFTER REPAIRClear the stored faults.
Follow the instructions to confirm repair.
Deal with any other faults.
CLIM_V44_DF007