air condition SSANGYONG KORANDO 2012 User Guide

SSANGYONG KORANDO 2012 User Guide KORANDO 2012 SSANGYONG SSANGYONG https://www.carmanualsonline.info/img/67/57504/w960_57504-0.png SSANGYONG KORANDO 2012 User Guide

Page 279 of 1082

SSANGYONG KORANDO 2012 User Guide 15-30000-00
1. ENGINE DATA LIST
Data Unit Value
Coolant temperature℃ 0.436 V (130℃) to 4.896 V (-40℃)
Intake air temperature℃ -40 to 130℃ (varies by ambient air 
temperature or engine mode)

Page 286 of 1082

SSANGYONG KORANDO 2012 User Guide 15-10
(2) Fuel Control
a. Fuel Pressure Control Elements
Pressure control consists of 2 principles.
Determines rail pressure according to engine operating conditions.
Controls IMV to make the rail pre

Page 288 of 1082

SSANGYONG KORANDO 2012 User Guide 15-12
Pilot injection timing control â–¶
The pilot injection timing is determined as a function of the engine speed and of the total flow.
The elements are:
A first correction is made according to the

Page 290 of 1082

SSANGYONG KORANDO 2012 User Guide 15-14
3. Idle Speed Controller
The idle speed controller consists of 2 principal modules:
The first module determines the required idle speed according to:
* The operating conditions of the engine (co

Page 295 of 1082

SSANGYONG KORANDO 2012 User Guide 15-190000-00
HFM
Accelerator pedalCoolant 
temperature
(4) Swirl control
a. Overview
Variable swirl valve -
The strong swirl caused by intake air is important element for anti-locking function in dies

Page 298 of 1082

SSANGYONG KORANDO 2012 User Guide 15-22
Load Engine speed Swirl 
valveAmount of 
swirlRemarks
Low speed,
Low loadbelow 3,000 rpm Closed HeavyIncreased EGR ratio, better air-fuel 
mixture (reduce exhaust gas)
High speed,
High loadover

Page 310 of 1082

SSANGYONG KORANDO 2012 User Guide 15-34
Coolant temp. 
sensor
(8) Cooling fan control
a. Overview of cooling fan and A/C compressor
The cooling system maintains the engine temperature at an efficient level during all engine operating

Page 315 of 1082

SSANGYONG KORANDO 2012 User Guide 15-390000-00
d. Control conditions
Operation Operating condition PTC Heater
HI
(PTC2)- Coolant temperature < 15℃
PTC  HI ON 
LO
(PTC1)- Coolant temperature 15℃ ≤ 65℃, intake air 
temperature â

Page 332 of 1082

SSANGYONG KORANDO 2012 User Guide 01-8
4) Basic Inspection
(1) Horn operation
Listen for the horn sound when pressing the horn pad on the steering wheel. -
(2) Brake operation
Check if there is any abnormal noise, unusually long braki

Page 355 of 1082

SSANGYONG KORANDO 2012 User Guide 02-91337-04
With HPS (Hydraulic Power Steering) With ESP (Electric Power Steering)
Length of belt : 1913mm Length of belt : 1740mm
1. Crankshaft pulley
2. Air conditioner compressor
3. Water pump
4. A
Page:   < prev 1-10 11-20 21-30 31-40 41-50 50 next >