coolant SSANGYONG MUSSO 2003 Owners Manual
[x] Cancel search | Manufacturer: SSANGYONG, Model Year: 2003, Model line: MUSSO, Model: SSANGYONG MUSSO 2003Pages: 1574, PDF Size: 26.41 MB
Page 608 of 1574

1F1-76 M162 ENGINE CONTROLS 2. Measure the resistance between the coolant temperaturesensor terminal No.1 and No.4 with the coolant temperature sensor disconnected.
Inspection 1. Measure the coolant sensor input voltage between the ECU
terminal No.79 and No.78 while the ignition switch in "ON" position. Notice Replace wiring and coolant temperature sensor if out of specified value. allowable error :
±5%
allowable error : ±5%
Voltage (V)
3.57 1.220.78
Temperature (
°C)
203040
Resistance (W) 2,500322 185
Temperature (
°C)
203040
Page 609 of 1574

M162 ENGINE CONTROLS 1F1-77
Service Data Resistance characteristic curve according to the coolant temperatureTemperature(
°C) Resistance(W) Voltage(V) Temperature( °C) Resistance(W) Voltage(V)
-40 48,550 4.8991 60 594 1.8632
-30 27,000 4.8214 70 434 1.5132
-20 15,670 4.7001 80 322 1.2179
-10 9,450 4.5215 90 243 0.9775 0 5,890 4.4273 100 185 0.7806
10 3,790 3.9562 110 143 0.6255
20 2,500 3.5714 120 111.6 0.5020
30 1,692 3.1426 130 88.0 0.4044
40 1,170 2.6959 140 71.2 0.3323 50 826 2.2618 - - -
Page 618 of 1574

OM600 ENGINE CONTROLS 1F3-7
Vacuum 500 mbar
Lines and connections leaking. Faulty PLA vacuum unit.
Test step 1
Connect vacuum pump (14) with Y adapter to PLA vacuum unit (5). Run engine at idle speed.YES NO
(Remove the connection hose from vacuum pump)
Connect vacuum pump (14) direct to PLA vacuum unit(5) and pressurize with vacuum.
Vacuum is built up and idle speed increases approx. 150-200 rpm
YES NO
Faulty PLA vacuum unit
(Coolant Temperature 30 °C)
Stop the engine Seal the air admission line with plug. Connect the vacuum pump to line to thermovalve andpressurize the line with vacuum.
Vacuum is built up.
YES NO
Lines and connectors leaking. Faulty thermovalve.
=
>
Page 626 of 1574

1F3-16 OM600 ENGINE CONTROLSIdle Speed
750 - 850 rpm 720 - 820 rpm
EngineOM661LA EngineOM662LA Engine
Tools Required 667 589 00 21 00 TDC Pulse Generato
Commercial Tool
IDLE SPEED ADJUSTMENT Service Data
e.g. Bosch, MOT 001.03
Sun, DIT 9000
Digital Tester
Adjustment Procedure
1. Connect the digital tester (1) and TDC pulse sender unit
(11).
2. Run the engine and warm up the coolant to 60~80 °C.
TDC pulse generator 667 589 02 21 00
3. Disconnect the vacuum hose (4) from the PLA unit to check idle speed with tester.
4. Check idle speed with tester.
Notice
To adjust idle speed, loosen the locking nut (6) of PLA unit.
OM 661LA Engine 750 - 850rpm
OM 662LA Engine
720 - 820rpm
Page 1157 of 1574

SECTION 7D
FULL AUTOMATIC TEMPERATURECONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM
Specifications . . . . . . . . . . . . . . . . . . . . . . . . 7D-1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 7D-1
Service Specifications . . . . . . . . . . . . . . . . . . . 7D-3
Schematic and Routing Diagrams . . . . . . . . 7D-4
Circuit Diagram . . . . . . . . . . . . . . . . . . . . . . . . 7D-4
FATC Block Diagram . . . . . . . . . . . . . . . . . . . . 7D-5
Component Locator . . . . . . . . . . . . . . . . . . . 7D-6 TABLE OF CONTENTS
Ventilation System . . . . . . . . . . . . . . . . . . . . . . 7D-6
Function Description . . . . . . . . . . . . . . . . . . . . 7D-7
Diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . 7D-8
Diagnosis Test . . . . . . . . . . . . . . . . . . . . . . . . 7D-8
Maintenance and Repair . . . . . . . . . . . . . . 7D-11 FATC Control Panel . . . . . . . . . . . . . . . . . . . 7D-11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . 7D-15
FATC (Full Automatic Temperature Control) is full automatic heater and airconditioning system that detects incar temperature, ambient temperature, sun load and coolant temperature and controls airconditioner system
blowing capacity, outlet temperature and intaking/outlet mode to maintain interior comfort.
SPECIFICATIONSSPECIFICATIONS
Application
Core Size (LxWxT)
Core Type
Expansion Valve Type Thermostat
Resister TypeCooling Capacity Description
237.0x232.0x92.0 Aluminum plate
Angle
ON:4.5±0.6 °C, OFF:1.5±0.6 °C
Aluminum plate
4,500 Kcal/h(AT 420 CMH)
Evaporator Unit
Application
Capacity
Type Description
650-750 g R134a
Refrigerant
Page 1159 of 1574

FATC-HAVC 7D-3
SERVICE SPECIFICATIONSResistance (25 °C)
Voltage Rating Current RatingResistance (25 °C)
Voltage Rating Current Rating Resistance (25 °C)
Voltage RatingCurrent Rating
Application
Incar Sensor Ambient Sensor
Coolant Temperature Sensor
Description
Input Section
2.186k
±0.07k
5V
3mA
1.0k ±0.03k
5V
3mA
0.55k ±0.02k
5V
3mA
Current Rating (at 12V) LOCK CurrentCurrent Rating (at 12V)LOCK CurrentCurrent Rating (at 12V) LOCK Current IcPc
Application
Intake Actuator Mode Actuator Mix Actuator Power TRBlower Motor Power Consumption
Description
Output Section
70±30mA
Less than 500mA 100±40mA
Less than 500mA 100±40mA
Less than 500mA 30A
200W 220W
Page 1165 of 1574

FATC-HAVC 7D-9
Diagnosis Item and Fault Code Self-diagnosis Display
1. Data will be displayed at the set temperature display as 2-digit number during self-diagnosis function and other settemperature displays will be OFF.
2. Display of self-diagnosis fault code will be blinking fault code number in the intervals of 0.5 sec.
3. Following fault code number will be displayed at the set temperature display during self-diagnosis function.
4. If no defective, normal display number (00) will blink. Display during continuous action
A. Normal or 1 fault (00 or 11) 15: coolant Sensor Open
16: coolant Sensor Short
17: temperature Actuator Open/Short
18: temperature Actuator Drive Fault
00: normal
11: incar Sensor Open
12: incar Sensor Short
13: ambient Sensor Open
14: ambient Sensor Short
B. Multiple faults (11,13,15.........) Display during step action
A. Normal or 1 fault : the same as continuous action
B. Multiple faults
0.1 sec. 0.1 sec.
0.5 sec.
ON
0.5 sec.OFF
ON
OFF
Display
Buzzer
0.5 sec.Fault 13
0.5 sec.OFF
Fault 15
OFF
Display
Buzzer
Fault 13 Fault 17
Display Buzzer AUTO switch pressedFault
17 Fault 17
Airconditioner switchpressedFault11 Fault 11
0.1 sec. 0.1 sec.
Page 1168 of 1574

7D-12 FATC-HAVC Pin Number and Connection Circuit
Pin No.1 Connection circuit
2 3456789
10 11
1213141516
Rheostat Tail lamp
Battery (+)
Power TR (B) Power TR (C)
Temperature actuator (CCW) IG2
Ground
Airconditioner switch ground HI speed relay
Photo sensor (+)
Photo sensor (-)
Temperature actuator F/B
Temperature actuator (CW) IG2
Ground
Connector A
Pin No.
1 Connection circuit
2 345 6 789
101112131415
Incar sensor (+)
Ambient sensor (+) Coolant sensor (+)
Sensor voltage 5V Sensor ground
Intake (ambient) Intake (incar)
- --
VENT
B/L
FLR MIX
DEF
--- - -
Connector B
17 18
19
20
16